Dynamic contrast-enhanced MRI measurement of renal function in healthy participants

被引:19
|
作者
Eikefjord, Eli [1 ,2 ]
Andersen, Erling [1 ,3 ]
Hodneland, Erlend [2 ,4 ]
Hanson, Erik A. [5 ]
Sourbron, Steven [6 ]
Svarstad, Einar [2 ,7 ]
Lundervold, Arvid [1 ,8 ]
Rorvik, Jarle T. [1 ,2 ]
机构
[1] Haukeland Hosp, Dept Radiol, Jonas Lies Vei 65, NO-5021 Bergen, Norway
[2] Univ Bergen, Dept Clin Med, Bergen, Norway
[3] Haukeland Hosp, Dept Clin Engn, Bergen, Norway
[4] Christian Michelsen Res CMR AS, Bergen, Norway
[5] Univ Bergen, Dept Math, Bergen, Norway
[6] Univ Leeds, Fac Med & Hlth, Leeds, W Yorkshire, England
[7] Haukeland Hosp, Dept Med, Bergen, Norway
[8] Univ Bergen, Dept Biomed, Bergen, Norway
关键词
Urinary; MR functional imaging; kidney; adults; imaging sequence; technology assessment; GLOMERULAR-FILTRATION-RATE; SINGLE KIDNEY-FUNCTION; DCE-MRI; RENOGRAPHY; GFR; MODEL; REPRODUCIBILITY; RESPONSES; PERFUSION; IOHEXOL;
D O I
10.1177/0284185116666417
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: High repeatability, accuracy, and precision for renal function measurements need to be achieved to establish renal dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) as a clinically useful diagnostic tool. Purpose: To investigate the repeatability, accuracy, and precision of DCE-MRI measured renal perfusion and glomerular filtration rate (GFR) using iohexol-GFR as the reference method. Material and Methods: Twenty healthy non-smoking volunteers underwent repeated DCE-MRI and an iohexol-GFR within a period of 10 days. Single-kidney (SK) MRI measurements of perfusion (blood flow, Fb) and filtration (GFR) were derived from parenchymal intensity time curves fitted to a two-compartment filtration model. The repeatability of the SK-MRI measurements was assessed using coefficient of variation (CV). Using iohexol-GFR as reference method, the accuracy of total MR-GFR was determined by mean difference (MD) and precision by limits of agreement (LoA). Results: SK-Fb (MR1, 345 +/- 84; MR2, 371 +/- 103 mL/100 mL/min) and SK-GFR (MR1, 52 +/- 14; MR2, 54 +/- 10 mL/min/ 1.73m(2)) measurements achieved a repeatability (CV) in the range of 15-22%. With reference to iohexol-GFR, MR-GFR was determined with a low mean difference but high LoA (MR1, MD 1.5 mL/min/1.73m(2), LoA [-42, 45]; MR2, MD 6.1 mL/min/1.73m(2), LoA [-26, 38]). Eighty percent and 90% of MR-GFR measurements were determined within +/- 30% of the iohexol-GFR for MR1 and MR2, respectively. Conclusion: Good repeatability of SK-MRI measurements and good agreement between MR-GFR and iohexol-GFR provide a high clinical potential of DCE-MRI for renal function assessment. A moderate precision in MR-derived estimates indicates that the method cannot yet be used in clinical routine.
引用
收藏
页码:748 / 757
页数:10
相关论文
共 50 条
  • [31] Dynamic contrast-enhanced MRI of ocular melanoma
    Jiang, Xuyuan
    Asbach, Patrick
    Willerding, Gregor
    Dulce, Miriam
    Xu, Ke
    Taupitz, Matthias
    Hamm, Bernd
    Erb-Eigner, Katharina
    MELANOMA RESEARCH, 2015, 25 (02) : 149 - 156
  • [32] A New Approach to Analysis of the Impulse Response Function (IRF) in Dynamic Contrast-Enhanced MRI (DCEMRI): A Simulation Study
    Fan, Xiaobing
    Karczmar, Gregory S.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 229 - 239
  • [33] Dynamic Contrast-Enhanced MRI-Based Early Detection of Acute Renal Transplant Rejection
    Khalifa, Fahmi
    Beache, Garth M.
    Abou El-Ghar, Mohamed
    El-Diasty, Tarek
    Gimel'farb, Georgy
    Kong, Maiying
    El-Baz, Ayman
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (10) : 1910 - 1927
  • [34] Contrast-enhanced dynamic magnetic resonance nephrography in healthy dogs
    Fonseca-Matheus, J. M.
    Perez-Garcia, C. C.
    Ginja, M. M. D.
    Altonaga, J. R.
    Orden, M. A.
    Gonzalo-Orden, J. M.
    VETERINARY JOURNAL, 2011, 189 (03) : 341 - 345
  • [35] Influence of Different Measurement Methods of Arterial Input Function on Quantitative Dynamic Contrast-Enhanced MRI Parameters in Head and Neck Cancer
    Dong, Wanxin
    Volk, Andreas
    Djaroum, Meriem
    Girot, Charly
    Balleyguier, Corinne
    Lebon, Vincent
    Garcia, Gabriel
    Ammari, Samy
    Temam, Stephane
    Gorphe, Philippe
    Wei, Lecong
    Pitre-Champagnat, Stephanie
    Lassau, Nathalie
    Bidault, Francois
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 58 (01) : 122 - 132
  • [36] Dynamic contrast-enhanced MRI in oncology: how we do it
    Petralia, Giuseppe
    Summers, Paul E.
    Agostini, Andrea
    Ambrosini, Roberta
    Cianci, Roberta
    Cristel, Giulia
    Calistri, Linda
    Colagrande, Stefano
    RADIOLOGIA MEDICA, 2020, 125 (12): : 1288 - 1300
  • [37] Selection of Fitting Model and Arterial Input Function for Repeatability in Dynamic Contrast-Enhanced Prostate MRI
    Peled, Sharon
    Vangel, Mark
    Kikinis, Ron
    Tempany, Clare M.
    Fennessy, Fiona M.
    Fedorov, Andrey
    ACADEMIC RADIOLOGY, 2019, 26 (09) : E241 - E251
  • [38] Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values
    Tofts, Paul S.
    Cutajar, Marica
    Mendichovszky, Iosif A.
    Peters, A. Michael
    Gordon, Isky
    EUROPEAN RADIOLOGY, 2012, 22 (06) : 1320 - 1330
  • [39] Precise measurement of renal filtration and vascular parameters using a two-compartment model for dynamic contrast-enhanced MRI of the kidney gives realistic normal values
    Paul S. Tofts
    Marica Cutajar
    Iosif A. Mendichovszky
    A. Michael Peters
    Isky Gordon
    European Radiology, 2012, 22 : 1320 - 1330
  • [40] How accurate is dynamic contrast-enhanced MRI in the assessment of renal glomerular filtration rate?: A critical appraisal
    Mendichovszky, Iosif
    Pederson, Michael
    Frokiaer, Jorgen
    Dissing, Thomas
    Grenier, Nicolas
    Anderson, Peter
    McHugh, Kieran
    Yang, Qing
    Gordon, Isky
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 925 - 931