Dynamic contrast-enhanced MRI measurement of renal function in healthy participants

被引:19
|
作者
Eikefjord, Eli [1 ,2 ]
Andersen, Erling [1 ,3 ]
Hodneland, Erlend [2 ,4 ]
Hanson, Erik A. [5 ]
Sourbron, Steven [6 ]
Svarstad, Einar [2 ,7 ]
Lundervold, Arvid [1 ,8 ]
Rorvik, Jarle T. [1 ,2 ]
机构
[1] Haukeland Hosp, Dept Radiol, Jonas Lies Vei 65, NO-5021 Bergen, Norway
[2] Univ Bergen, Dept Clin Med, Bergen, Norway
[3] Haukeland Hosp, Dept Clin Engn, Bergen, Norway
[4] Christian Michelsen Res CMR AS, Bergen, Norway
[5] Univ Bergen, Dept Math, Bergen, Norway
[6] Univ Leeds, Fac Med & Hlth, Leeds, W Yorkshire, England
[7] Haukeland Hosp, Dept Med, Bergen, Norway
[8] Univ Bergen, Dept Biomed, Bergen, Norway
关键词
Urinary; MR functional imaging; kidney; adults; imaging sequence; technology assessment; GLOMERULAR-FILTRATION-RATE; SINGLE KIDNEY-FUNCTION; DCE-MRI; RENOGRAPHY; GFR; MODEL; REPRODUCIBILITY; RESPONSES; PERFUSION; IOHEXOL;
D O I
10.1177/0284185116666417
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: High repeatability, accuracy, and precision for renal function measurements need to be achieved to establish renal dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) as a clinically useful diagnostic tool. Purpose: To investigate the repeatability, accuracy, and precision of DCE-MRI measured renal perfusion and glomerular filtration rate (GFR) using iohexol-GFR as the reference method. Material and Methods: Twenty healthy non-smoking volunteers underwent repeated DCE-MRI and an iohexol-GFR within a period of 10 days. Single-kidney (SK) MRI measurements of perfusion (blood flow, Fb) and filtration (GFR) were derived from parenchymal intensity time curves fitted to a two-compartment filtration model. The repeatability of the SK-MRI measurements was assessed using coefficient of variation (CV). Using iohexol-GFR as reference method, the accuracy of total MR-GFR was determined by mean difference (MD) and precision by limits of agreement (LoA). Results: SK-Fb (MR1, 345 +/- 84; MR2, 371 +/- 103 mL/100 mL/min) and SK-GFR (MR1, 52 +/- 14; MR2, 54 +/- 10 mL/min/ 1.73m(2)) measurements achieved a repeatability (CV) in the range of 15-22%. With reference to iohexol-GFR, MR-GFR was determined with a low mean difference but high LoA (MR1, MD 1.5 mL/min/1.73m(2), LoA [-42, 45]; MR2, MD 6.1 mL/min/1.73m(2), LoA [-26, 38]). Eighty percent and 90% of MR-GFR measurements were determined within +/- 30% of the iohexol-GFR for MR1 and MR2, respectively. Conclusion: Good repeatability of SK-MRI measurements and good agreement between MR-GFR and iohexol-GFR provide a high clinical potential of DCE-MRI for renal function assessment. A moderate precision in MR-derived estimates indicates that the method cannot yet be used in clinical routine.
引用
收藏
页码:748 / 757
页数:10
相关论文
共 50 条
  • [1] Assessment of renal function using intravoxel incoherent motion diffusion-weighted imaging and dynamic contrast-enhanced MRI
    Bane, Octavia
    Wagner, Mathilde
    Zhang, Jeff L.
    Dyvorne, Hadrien A.
    Orton, Matthew
    Rusinek, Henry
    Taouli, Bachir
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (02) : 317 - 326
  • [2] Shape-based motion correction in dynamic contrast-enhanced MRI for quantitative assessment of renal function
    Liu, Wenyang
    Sung, Kyunghyun
    Ruan, Dan
    MEDICAL PHYSICS, 2014, 41 (12)
  • [3] Measurement of renal volumes with contrast-enhanced MRI
    Coulam, CH
    Bouley, DM
    Sommer, FG
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (02) : 174 - 179
  • [4] Classic models for dynamic contrast-enhanced MRI
    Sourbron, Steven P.
    Buckley, David L.
    NMR IN BIOMEDICINE, 2013, 26 (08) : 1004 - 1027
  • [5] A renal vascular compartment segmentation method based on dynamic contrast-enhanced images
    Li, Hong
    Bao, Nan
    Xu, Xieping
    Zhang, Yaonan
    Jin, Shikai
    Jin, Yueming
    Sun, Haoran
    TECHNOLOGY AND HEALTH CARE, 2016, 24 : S631 - S639
  • [6] Dynamic Contrast-Enhanced (DCE) MRI
    Li, Xin
    Huang, Wei
    Holmes, James H.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2024, 32 (01) : 47 - 61
  • [7] Measurement of Placental Perfusion by Dynamic Contrast-Enhanced MRI at 4.7 T
    Alison, Marianne
    Quibel, Thibault
    Balvay, Daniel
    Autret, Gwennhael
    Bourillon, Camille
    Chalouhi, Gihad E.
    Deloison, Benjamin
    Salomon, Laurent J.
    Cuenod, Charles Andre
    Clement, Olivier
    Siauve, Nathalie
    INVESTIGATIVE RADIOLOGY, 2013, 48 (07) : 535 - 542
  • [8] Reproducibility and Optimal Arterial Input Function Selection in Dynamic Contrast-Enhanced Perfusion MRI in the Healthy Brain
    Cramer, Stig P.
    Larsson, Henrik B. W.
    Knudsen, Maria H.
    Simonsen, Helle J.
    Vestergaard, Mark B.
    Lindberg, Ulrich
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (04) : 1229 - 1240
  • [9] Comparison of Dynamic Contrast-Enhanced MRI and Dynamic Contrast-Enhanced CT Biomarkers in Bladder Cancer
    Naish, J. H.
    McGrath, D. M.
    Bains, L. J.
    Passera, K.
    Roberts, C.
    Watson, Y.
    Cheung, S.
    Taylor, M. B.
    Logue, J. P.
    Buckley, D. L.
    Tessier, J.
    Young, H.
    Waterton, J. C.
    Parker, G. J. M.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 219 - 226
  • [10] Correction of arterial input function in dynamic contrast-enhanced MRI of the liver
    Wang, Hesheng
    Cao, Yue
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (02) : 411 - 421