Displacement-encoded cardiac MRI using cosine and sine modulation to eliminate (CANSEL) artifact-generating echoes

被引:51
作者
Epstein, FH
Gilson, WD
机构
[1] Univ Virginia, Dept Radiol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Cardiovasc Res Ctr, Charlottesville, VA 22908 USA
关键词
MRI; myocardial tagging; displacement encoding using stimulated echoes (DENSE); harmonic phase imaging (HARP); heart; mice; stimulated echoes;
D O I
10.1002/mrm.20232
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Displacement-encoded imaging with stimulated echoes (DENSE) and harmonic phase imaging (HARP) employ 1-1 spatial modulation of magnetization to cosine modulate the longitudinal magnetization as a function of position at end diastole. Later in the cardiac cycle they sample the cosine-modulated signal and compute myocardial strain from the signal phase. The sampled signal generally includes three distinct echoes. 1) a displacement-encoded stimulated echo, 2) the complex conjugate of the displacement-encoded echo, and 3) an echo arising from T-1 relaxation. If the T-1-relaxation and complex conjugate echoes are suppressed, then a phase image representing just the displacement-encoded echo can be reconstructed. In the present study, the use of cosine and sine modulation to eliminate (CANSEL) the T-1-relaxation and complex conjugate echoes was investigated. With the use of CANSEL, it was demonstrated that DENSE accurately measures through-plane as well as in-plane components of tissue motion. Also, DENSE with CANSEL artifact suppression can provide increased signal-to-noise ratio (SNR) secondary to reduced intravoxel dephasing by using relatively low displacement-encoding frequencies. For applications that employ DENSE imaging with multiple acquisitions, the CANSEL technique can suppress artifact-generating echoes without placing constraints on the displacement-encoding frequency and direction. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:774 / 781
页数:8
相关论文
共 18 条
  • [11] Myocardial tissue tracking with two-dimensional cine displacement-encoded MR imaging: Development and initial evaluation
    Kim, D
    Gilson, WD
    Kramer, CM
    Epstein, FH
    [J]. RADIOLOGY, 2004, 230 (03) : 862 - 871
  • [12] Kuijer JPA, 2001, MAGN RESON MED, V46, P993, DOI 10.1002/mrm.1286
  • [13] Osman NF, 1999, MAGN RESON MED, V42, P1048, DOI 10.1002/(SICI)1522-2594(199912)42:6<1048::AID-MRM9>3.0.CO
  • [14] 2-M
  • [15] Imaging longitudinal cardiac strain on short-axis images using strain-encoded MRI
    Osman, NF
    Sampath, S
    Atalar, E
    Prince, JL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) : 324 - 334
  • [16] Visualizing myocardial function using HARP MRI
    Osman, NF
    Prince, JL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (06) : 1665 - 1682
  • [17] Imaging heart motion using harmonic phase MRI
    Osman, NF
    McVeigh, ER
    Prince, JL
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (03) : 186 - 202
  • [18] Stimulated anti-echo selection in spatially localized NMR spectroscopy
    Zhu, JM
    Smith, ICP
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1999, 136 (01) : 1 - 5