Displacement-encoded cardiac MRI using cosine and sine modulation to eliminate (CANSEL) artifact-generating echoes

被引:51
作者
Epstein, FH
Gilson, WD
机构
[1] Univ Virginia, Dept Radiol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Cardiovasc Res Ctr, Charlottesville, VA 22908 USA
关键词
MRI; myocardial tagging; displacement encoding using stimulated echoes (DENSE); harmonic phase imaging (HARP); heart; mice; stimulated echoes;
D O I
10.1002/mrm.20232
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Displacement-encoded imaging with stimulated echoes (DENSE) and harmonic phase imaging (HARP) employ 1-1 spatial modulation of magnetization to cosine modulate the longitudinal magnetization as a function of position at end diastole. Later in the cardiac cycle they sample the cosine-modulated signal and compute myocardial strain from the signal phase. The sampled signal generally includes three distinct echoes. 1) a displacement-encoded stimulated echo, 2) the complex conjugate of the displacement-encoded echo, and 3) an echo arising from T-1 relaxation. If the T-1-relaxation and complex conjugate echoes are suppressed, then a phase image representing just the displacement-encoded echo can be reconstructed. In the present study, the use of cosine and sine modulation to eliminate (CANSEL) the T-1-relaxation and complex conjugate echoes was investigated. With the use of CANSEL, it was demonstrated that DENSE accurately measures through-plane as well as in-plane components of tissue motion. Also, DENSE with CANSEL artifact suppression can provide increased signal-to-noise ratio (SNR) secondary to reduced intravoxel dephasing by using relatively low displacement-encoding frequencies. For applications that employ DENSE imaging with multiple acquisitions, the CANSEL technique can suppress artifact-generating echoes without placing constraints on the displacement-encoding frequency and direction. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:774 / 781
页数:8
相关论文
共 18 条
  • [1] Mixed echo train acquisition displacement encoding with stimulated echoes: An optimized DENSE method for in vivo functional imaging of the human heart
    Aletras, AH
    Wen, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) : 523 - 534
  • [2] Aletras AH, 1999, J MAGN RESON, V140, P41, DOI 10.1006/jmre/1999.1821
  • [3] DENSE: Displacement encoding with stimulated echoes in cardiac functional MRI
    Aletras, AH
    Ding, SJ
    Balaban, RS
    Wen, H
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1999, 137 (01) : 247 - 252
  • [4] MR IMAGING OF MOTION WITH SPATIAL MODULATION OF MAGNETIZATION
    AXEL, L
    DOUGHERTY, L
    [J]. RADIOLOGY, 1989, 171 (03) : 841 - 845
  • [5] SUPPRESSION OF ARTIFACTS IN 2-DIMENSIONAL J SPECTROSCOPY
    BODENHAUSEN, G
    FREEMAN, R
    TURNER, DL
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1977, 27 (03) : 511 - 514
  • [6] EPSTEIN FH, 2003, P 11 AN M ISMRM TOR, P1566
  • [7] IMPROVED MYOCARDIAL TAGGING CONTRAST
    FISCHER, SE
    MCKINNON, GC
    MAIER, SE
    BOESIGER, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 191 - 200
  • [8] LIMITATIONS OF STIMULATED ECHO ACQUISITION MODE (STEAM) TECHNIQUES IN CARDIAC APPLICATIONS
    FISCHER, SE
    STUBER, M
    SCHEIDEGGER, MB
    BOESIGER, P
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) : 80 - 91
  • [9] Complementary displacement-encoded MRI for contrast-enhanced infarct detection and quantification of myocardial function in mice
    Gilson, WD
    Yang, ZQ
    French, BA
    Epstein, FH
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 744 - 752
  • [10] CRITICAL FACTORS IN DESIGN OF SENSITIVE HIGH-RESOLUTION NUCLEAR MAGNETIC-RESONANCE SPECTROMETERS
    HOULT, DI
    RICHARDS, RE
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1975, 344 (1638): : 311 - 340