Reducing respiratory effect in motion correction for EPI images with sequential slice acquisition order

被引:5
作者
Cheng, Hu [1 ,2 ]
Puce, Aina [1 ,2 ]
机构
[1] Indiana Univ, Imaging Res Facil, Bloomington, IN USA
[2] Indiana Univ, Dept Psychol & Brain Sci, Bloomington, IN 47405 USA
关键词
Motion correction; Respiratory noise; fMRI; EPI; Sequential acquisition; FMRI; BRAIN; FLUCTUATIONS; NOISE;
D O I
10.1016/j.jneumeth.2014.02.007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Motion correction is critical for data analysis of fMRI time series. Most motion correction algorithms treat the head as a rigid body. Respiration of the subject, however, can alter the static magnetic field in the head and result in motion-like slice shifts for echo planar imaging (EPI). The delay of acquisition between slices causes a phase difference in respiration so that the shifts vary with slice positions. To characterize the effect of respiration on motion correction, we acquired fast sampled fMRI data using multi-band EPI and then simulated different acquisition schemes. Our results indicated that respiration introduces additional noise after motion correction. The signal variation between volumes after motion correction increases when the effective TR increases from 675 ms to 2025 ms. This problem can be corrected if slices are acquired sequentially. For EPI with a sequential acquisition scheme, we propose to divide the image volumes into several segments so that slices within each segment are acquired close in time and then perform motion correction on these segments separately. We demonstrated that the temporal signal-to-noise ratio (TSNR) was increased when the motion correction was performed on the segments separately rather than on the whole image. This enhancement of TSNR was not evenly distributed across the segments and was not observed for interleaved acquisition. The level of increase was higher for superior slices. On superior slices the percentage of TSNR gain was comparable to that using image based retrospective correction for respiratory noise. Our results suggest that separate motion correction on segments is highly recommended for sequential acquisition schemes, at least for slices distal to the chest. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:83 / 89
页数:7
相关论文
共 22 条
[1]   Separating respiratory-variation-related neuronal-activity-related fluctuations in fluctuations from fMRI [J].
Birn, RM ;
Diamond, JB ;
Smith, MA ;
Bandettini, PA .
NEUROIMAGE, 2006, 31 (04) :1536-1548
[2]   Respiratory noise correction using phase information [J].
Cheng, Hu ;
Li, Yu .
MAGNETIC RESONANCE IMAGING, 2010, 28 (04) :574-582
[3]   Multiplexed Echo Planar Imaging for Sub-Second Whole Brain FMRI and Fast Diffusion Imaging [J].
Feinberg, David A. ;
Moeller, Steen ;
Smith, Stephen M. ;
Auerbach, Edward ;
Ramanna, Sudhir ;
Glasser, Matt F. ;
Miller, Karla L. ;
Ugurbil, Kamil ;
Yacoub, Essa .
PLOS ONE, 2010, 5 (12)
[4]  
Glover GH, 2000, MAGNET RESON MED, V44, P162, DOI 10.1002/1522-2594(200007)44:1<162::AID-MRM23>3.0.CO
[5]  
2-E
[6]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[7]   RETROSPECTIVE ESTIMATION AND CORRECTION OF PHYSIOLOGICAL FLUCTUATION IN FUNCTIONAL MRI [J].
HU, XP ;
LE, TH ;
PARRISH, T ;
ERHARD, P .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :201-212
[8]   Physiological noise in oxygenation-sensitive magnetic resonance imaging [J].
Krüger, G ;
Glover, GH .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) :631-637
[9]   Non-white noise in fMRI: Does modelling have an impact? [J].
Lund, TE ;
Madsen, KH ;
Sidaros, K ;
Luo, WL ;
Nichols, TE .
NEUROIMAGE, 2006, 29 (01) :54-66
[10]   Prospective motion correction in brain imaging: A review [J].
Maclaren, Julian ;
Herbst, Michael ;
Speck, Oliver ;
Zaitsev, Maxim .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (03) :621-636