Patient Radiation Exposure in a Modern, Large-Volume, Pediatric Cardiac Catheterization Laboratory

被引:56
作者
Glatz, Andrew C. [1 ,2 ,3 ]
Patel, Akash [1 ,2 ]
Zhu, Xiaowei [4 ]
Dori, Yoav [1 ,2 ]
Hanna, Brian D. [1 ,2 ]
Gillespie, Matthew J. [1 ,2 ]
Rome, Jonathan J. [1 ,2 ]
机构
[1] Childrens Hosp Philadelphia, Div Cardiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Pediat, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Univ Penn, Ctr Clin Epidemiol & Biostat, Perelman Sch Med, Philadelphia, PA 19104 USA
[4] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
关键词
Catheterization; Radiation; Pediatric; Risk factors; CANCER-RISKS; CHILDREN; REDUCTION; MORTALITY; SAFETY; DAMAGE;
D O I
10.1007/s00246-014-0869-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Radiation exposure from pediatric cardiac catheterization may be substantial, although published estimates vary. We sought to report patient radiation dose across a range of diagnostic and interventional cases in a modern, high-volume pediatric catheterization laboratory. We retrospectively reviewed diagnostic and interventional cases performed in our pediatric catheterization laboratory from 1 April 2009 to 30 September 2011 for which radiation usage data were available as reported by the Artis Zee(A (R)) (Siemens Medical Solutions) system. Electrophysiology cases were excluded. Radiation dose was quantified as air kerma dose (mGy) and dose-area product (DAP; mu Gy m(2)). The DAP was converted to an effective dose millisievert (mSv) using the Monte Carlo method. Radiation usage data were available from 2,265 diagnostic and interventional cases with an overall median air kerma dose of 135 mGy [interquartile range (IQR) 59-433], median DAP of 760 mu Gy m(2) (IQR 281-2,810), of which 75 % (IQR 59-90 %) was derived from fluoroscopy, and median effective dose of 6.2 mSv (IQR 2.7-14.1). Air kerma dose from a single camera > 2,000 mGy occurred in 1.8 % of cases. Significant differences in all measures of radiation exposure existed based on procedural and interventional types (p = 0.0001), with interventional cases associated with the highest effective dose after adjusting for patient weight category (p < 0.001). Patient weight, age, fluoroscopy time, and proportional use of digital acquisition were independent predictors of exposure (p a parts per thousand currency sign 0.001; R (2) = 0.59-0.64). In a modern, large-volume pediatric catheterization laboratory, the median effective dose is 6.2 mSv with a wide range of exposure based on patient- and procedure-specific factors. Radiation monitoring is an important component of a pediatric laboratory and further dose reduction strategies are warranted.
引用
收藏
页码:870 / 878
页数:9
相关论文
共 50 条
[21]   Study of radiation doses to personnel in a cardiac catheterization laboratory [J].
McKetty, MH .
HEALTH PHYSICS, 1996, 70 (04) :563-567
[22]   Radiation Reduction in Pediatric and Adult Congenital Patients During Cardiac Catheterization [J].
Mauriello, Daniel A. ;
Fetterly, Kenneth A. ;
Lennon, Ryan J. ;
Reeder, Guy S. ;
Taggart, Nathaniel W. ;
Hagler, Donald J. ;
Cetta, Frank ;
Cabalka, Allison K. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (05) :801-808
[23]   Radiation safety in the cardiac catheterization laboratory: Basic principles [J].
Balter, S .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 1999, 47 (02) :229-236
[24]   REVIEW OF RADIATION SAFETY IN THE CARDIAC-CATHETERIZATION LABORATORY [J].
JOHNSON, LW ;
MOORE, RJ ;
BALTER, S .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 25 (03) :186-194
[25]   Heparin Dosing in Obese Pediatric Patients in the Cardiac Catheterization Laboratory [J].
Moffett, Brady S. ;
Teruya, Jun ;
Petit, Christopher .
ANNALS OF PHARMACOTHERAPY, 2011, 45 (7-8) :876-880
[26]   Near Infrared Spectroscopy Monitoring in the Pediatric Cardiac Catheterization Laboratory [J].
Tanidir, Ibrahim Cansaran ;
Ozturk, Erkut ;
Ozyilmaz, Isa ;
Saygi, Murat ;
Kiplapinar, Neslihan ;
Haydin, Sertac ;
Guzeltas, Alper ;
Odemis, Ender .
ARTIFICIAL ORGANS, 2014, 38 (10) :838-844
[27]   Radiation Protocol for Three-Dimensional Rotational Angiography to Limit Procedural Radiation Exposure in the Pediatric Cardiac Catheterization Lab [J].
Haddad, Lauren ;
Waller, B. Rush ;
Johnson, Jason ;
Choudhri, Asim ;
McGhee, Vera ;
Zurakowski, David ;
Kuhls-Gilcrist, Andrew ;
Sathanandam, Shyam .
CONGENITAL HEART DISEASE, 2016, 11 (06) :637-646
[28]   Simulator training to minimize ionizing radiation exposure in the catheterization laboratory [J].
Katz, Aric ;
Shtub, Avraham ;
Solomonica, Amir ;
Poliakov, Adva ;
Roguin, Ariel .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (03) :303-310
[29]   Simulator training to minimize ionizing radiation exposure in the catheterization laboratory [J].
Aric Katz ;
Avraham Shtub ;
Amir Solomonica ;
Adva Poliakov ;
Ariel Roguin .
The International Journal of Cardiovascular Imaging, 2017, 33 :303-310
[30]   Determinants of operator and patient radiation exposure during cardiac catheterization: Insights from the RadiCure (RADIation reduction during cardiac catheterization using real-timE monitoring) trial [J].
Christopoulos, Georgios ;
Papayannis, Aristotelis C. ;
Alomar, Mohammed ;
Christakopoulos, Georgios E. ;
Kotsia, Anna ;
Michael, Tesfaldet T. ;
Rangan, Bavana V. ;
Roesle, Michele ;
Shorrock, Deborah ;
Makke, Lorenza ;
Maragkoudakis, Spyros ;
Mohammad, Atif ;
Sarode, Karan ;
Chambers, Charles E. ;
Banerjee, Subhash ;
Brilakis, Emmanouil S. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (07) :1046-1055