Patient Radiation Exposure in a Modern, Large-Volume, Pediatric Cardiac Catheterization Laboratory

被引:54
|
作者
Glatz, Andrew C. [1 ,2 ,3 ]
Patel, Akash [1 ,2 ]
Zhu, Xiaowei [4 ]
Dori, Yoav [1 ,2 ]
Hanna, Brian D. [1 ,2 ]
Gillespie, Matthew J. [1 ,2 ]
Rome, Jonathan J. [1 ,2 ]
机构
[1] Childrens Hosp Philadelphia, Div Cardiol, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Pediat, Perelman Sch Med, Philadelphia, PA 19104 USA
[3] Univ Penn, Ctr Clin Epidemiol & Biostat, Perelman Sch Med, Philadelphia, PA 19104 USA
[4] Childrens Hosp Philadelphia, Dept Radiol, Philadelphia, PA 19104 USA
关键词
Catheterization; Radiation; Pediatric; Risk factors; CANCER-RISKS; CHILDREN; REDUCTION; MORTALITY; SAFETY; DAMAGE;
D O I
10.1007/s00246-014-0869-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Radiation exposure from pediatric cardiac catheterization may be substantial, although published estimates vary. We sought to report patient radiation dose across a range of diagnostic and interventional cases in a modern, high-volume pediatric catheterization laboratory. We retrospectively reviewed diagnostic and interventional cases performed in our pediatric catheterization laboratory from 1 April 2009 to 30 September 2011 for which radiation usage data were available as reported by the Artis Zee(A (R)) (Siemens Medical Solutions) system. Electrophysiology cases were excluded. Radiation dose was quantified as air kerma dose (mGy) and dose-area product (DAP; mu Gy m(2)). The DAP was converted to an effective dose millisievert (mSv) using the Monte Carlo method. Radiation usage data were available from 2,265 diagnostic and interventional cases with an overall median air kerma dose of 135 mGy [interquartile range (IQR) 59-433], median DAP of 760 mu Gy m(2) (IQR 281-2,810), of which 75 % (IQR 59-90 %) was derived from fluoroscopy, and median effective dose of 6.2 mSv (IQR 2.7-14.1). Air kerma dose from a single camera > 2,000 mGy occurred in 1.8 % of cases. Significant differences in all measures of radiation exposure existed based on procedural and interventional types (p = 0.0001), with interventional cases associated with the highest effective dose after adjusting for patient weight category (p < 0.001). Patient weight, age, fluoroscopy time, and proportional use of digital acquisition were independent predictors of exposure (p a parts per thousand currency sign 0.001; R (2) = 0.59-0.64). In a modern, large-volume pediatric catheterization laboratory, the median effective dose is 6.2 mSv with a wide range of exposure based on patient- and procedure-specific factors. Radiation monitoring is an important component of a pediatric laboratory and further dose reduction strategies are warranted.
引用
收藏
页码:870 / 878
页数:9
相关论文
共 50 条
  • [1] Patient Radiation Exposure in a Modern, Large-Volume, Pediatric Cardiac Catheterization Laboratory
    Andrew C. Glatz
    Akash Patel
    Xiaowei Zhu
    Yoav Dori
    Brian D. Hanna
    Matthew J. Gillespie
    Jonathan J. Rome
    Pediatric Cardiology, 2014, 35 : 870 - 878
  • [2] Characterization of radiation exposure and effect of a radiation monitoring policy in a large volume pediatric cardiac catheterization lab
    Verghese, George R.
    McElhinney, Doff B.
    Strauss, Keith J.
    Bergersen, Lisa
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (02) : 294 - 301
  • [3] Relationship of Beam Angulation and Radiation Exposure in the Cardiac Catheterization Laboratory
    Agarwal, Shikhar
    Parashar, Akhil
    Bajaj, Navkaranbir Singh
    Khan, Imran
    Ahmad, Imran
    Heupler, Fredrick A., Jr.
    Bunte, Matthew
    Modi, Dhruv K.
    Tuzcu, E. Murat
    Kapadia, Samir R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (05) : 558 - 566
  • [4] Measures to Reduce Radiation in a Modern Cardiac Catheterization Laboratory
    Agarwal, Shikhar
    Parashar, Akhil
    Ellis, Stephen G.
    Heupler, Frederick A., Jr.
    Lau, Evan
    Tuzcu, E. Murat
    Kapadia, Samir R.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (04) : 447 - +
  • [5] Radiation protection in the cardiac catheterization laboratory
    Biso, Sylvia Marie R.
    Vidovich, Mladen, I
    JOURNAL OF THORACIC DISEASE, 2020, 12 (04) : 1648 - 1655
  • [6] Radiation Dose to the Pediatric Cardiac Catheterization and Intervention Patient
    Chida, Koichi
    Ohno, Tadayuki
    Kakizaki, Shuhei
    Takegawa, Mika
    Yuuki, Hiroko
    Nakada, Mitsuru
    Takahashi, Shoki
    Zuguchi, Masayuki
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (05) : 1175 - 1179
  • [7] Review Transesophageal echocardiography in the pediatric interventional cardiac catheterization laboratory
    Hunter, Katie
    Cibiras, John
    Bingler, Michael
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2020, 58
  • [8] Occupational and patient radiation doses in a modern cardiac electrophysiology laboratory
    Wunderle, Kevin A.
    Chung, Mina K.
    Rayadurgam, Sripriya
    Miller, Mark A.
    Obuchowski, Nancy A.
    Lindsay, Bruce D.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 56 (02) : 183 - 190
  • [9] Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization
    Bacher, K
    Bogaert, E
    Lapere, R
    De Wolf, D
    Thierens, H
    CIRCULATION, 2005, 111 (01) : 83 - 89
  • [10] Quantification of Temporal, Procedural, and Hardware-Related Factors Influencing Radiation Exposure During Pediatric Cardiac Catheterization
    Smith, Benjamin G.
    Tibby, Shane M.
    Qureshi, Shakeel A.
    Rosenthal, Eric
    Krasemann, Thomas
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (06) : 931 - 936