Investigation of EBT3 radiochromic film's response to humidity

被引:21
作者
Leon-Marroquin, Elsa Y. [1 ]
Larraga-Gutierrez, Jose M. [2 ,3 ]
Alfredo Herrera-Gonzalez, J. [2 ,3 ]
Camacho-Lopez, Miguel A. [1 ]
Villarreal Barajas, Jose E. [4 ,5 ]
Garcia-Garduno, Olivia A. [2 ,3 ]
机构
[1] Univ Autonoma Estado Mexico, Fac Med, Lab Fotomed Biofoton & Espectroscopia Laser Pulso, Toluca, Mexico
[2] Inst Nacl Neurol & Neurocirug, Lab Fis Med, Mexico City, DF, Mexico
[3] Inst Nacl Neurol & Neurocirug, Unidad Radiocirugia, Mexico City, DF, Mexico
[4] Univ Calgary, Dept Oncol, Calgary, AB, Canada
[5] Univ Calgary, Dept Fis & Astron, Calgary, AB, Canada
关键词
EBT3 radiochromic film; humidity; net optical density; DOSIMETRY; ELECTRON; PHOTON;
D O I
10.1002/acm2.12337
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this work is to investigate the effects of immersing EBT3 radiochromic film in water and to evaluate its contribution to the total uncertainty in dose determination. Materials and methods: We used 3 cm x 3 cm EBT3 radiochromic films irradiated in the range of 0-70 Gy to study the impact of water immersion on the change in net optical density. These films were placed in a water container for a period of 24 h. The net optical density was measured before (0 h) and after of the immersion in water (1, 3, 6, 12, 18, and 24 h). The absorbance spectrum of the EBT3 radiochromic film was measured at 0 h and 24 h after immersion in water. The uncertainty in dose determination due to the effects of keeping the EBT3 radiochromic film submerged in water at 0, 1, and 24 h were recorded in the red, green, and blue channels. Results: We observed an increase in the net optical density as an effect on the film due to its immersion in water. The penetration of the water at the edges of the radiochromic film was observed to be a function of time during which the film remained in the water. On the other hand, the penetration of water at the edges of the film was found to be independent of irradiation dose. Conclusions: EBT3 radiochromic film is found more resistant to water penetration through the edges than its predecessors. However, there is evidence that suggest that liquid water damage the Nylon cover layer of the film by changing its optical properties. Therefore, it is recommended to build a new calibration curve for radiochromic films for a specific situation involving dose measurements in liquid water.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 50 条
[31]   Energy response of the GAFCHROMIC EBT3 in diagnosis range [J].
Gotanda, T. ;
Katsuda, T. ;
Gotanda, R. ;
Kuwano, T. ;
Akagawa, T. ;
Tanki, N. ;
Tabuchi, A. ;
Shimono, T. ;
Kawaji, Y. ;
Ideguchi, T. .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 :752-755
[32]   COMPARISON OF DIFFERENT TECHNIQUES FOR EVALUATION OF DOSE DISTRIBUTIONS IN RADIOTHERAPY USING RADIOCHROMIC EBT3 FILMS [J].
Dufek, V ;
Horakova, I ;
Koniarova, I .
RADIATION PROTECTION DOSIMETRY, 2019, 186 (2-3) :357-361
[33]   UNLAMINATED GAFCHROMIC EBT3 FILM FOR ULTRAVIOLET RADIATION MONITORING [J].
Welch, David ;
Randers-Pehrson, Gerhard ;
Spotnitz, Henry M. ;
Brenner, David J. .
RADIATION PROTECTION DOSIMETRY, 2017, 176 (04) :341-346
[34]   A comparison between radiochromic EBT2 film model and its predecessor EBT film model [J].
Carrasco, M. A. ;
Perucha, M. ;
Luis, F. J. ;
Baeza, M. ;
Herrador, M. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (04) :412-422
[35]   Growth kinetics of the EBT3 and EBT-XD films response in radiotherapy beams [J].
Momin, Shadab ;
Khan, Rao ;
Darafsheh, Arash .
OPTICS AND IONIZING RADIATION, 2020, 2020, 11224
[36]   On energy dependency, spectral properties, and orientation dependency of EBT3, EBT-XD, MD-V3, and HD-V2 radiochromic films [J].
Darafsheh, Arash .
PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (08)
[37]   Radiochromic EBT2 film dosimetry for low-energy protontherapy [J].
Angellier, G. ;
Gautier, M. ;
Herault, J. .
MEDICAL PHYSICS, 2011, 38 (11) :6171-6177
[38]   Adaptive calibration of Gafchromic EBT3 film using generalized additive neural networks [J].
Chang, Liyun ;
Chen, Pang-Yu ;
Yeh, Shyh-An ;
Kang, Chen-Lin ;
Su, Chun-Ting ;
Lee, Tsair-Fwu .
SCIENTIFIC REPORTS, 2025, 15 (01)
[39]   Optical Response of Expired EBT3 Film for Absorbed Dose Measurement in X-ray and Electron Beam Range [J].
Musa, Maisarah ;
Abu Mhanna, Hamad Yahia ;
Omar, Ahmad Fairuz ;
Radzi, Yasmin Md ;
Akhdar, Hanan Fawaz ;
Ishak, Nor Hafizah ;
Al Ewaidat, Haytham .
APPLIED SCIENCES-BASEL, 2022, 12 (08)
[40]   Spectroscopic parametrization of dose-dependent changes in EBT3 film [J].
Pecic, Stevan ;
Vicic, Milos ;
Kurij, Ljubomir ;
Belca, Ivan ;
Stojadinovic, Strahinja ;
Devic, Slobodan .
RADIATION PHYSICS AND CHEMISTRY, 2024, 223