Investigation of EBT3 radiochromic film's response to humidity

被引:21
作者
Leon-Marroquin, Elsa Y. [1 ]
Larraga-Gutierrez, Jose M. [2 ,3 ]
Alfredo Herrera-Gonzalez, J. [2 ,3 ]
Camacho-Lopez, Miguel A. [1 ]
Villarreal Barajas, Jose E. [4 ,5 ]
Garcia-Garduno, Olivia A. [2 ,3 ]
机构
[1] Univ Autonoma Estado Mexico, Fac Med, Lab Fotomed Biofoton & Espectroscopia Laser Pulso, Toluca, Mexico
[2] Inst Nacl Neurol & Neurocirug, Lab Fis Med, Mexico City, DF, Mexico
[3] Inst Nacl Neurol & Neurocirug, Unidad Radiocirugia, Mexico City, DF, Mexico
[4] Univ Calgary, Dept Oncol, Calgary, AB, Canada
[5] Univ Calgary, Dept Fis & Astron, Calgary, AB, Canada
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2018年 / 19卷 / 03期
关键词
EBT3 radiochromic film; humidity; net optical density; DOSIMETRY; ELECTRON; PHOTON;
D O I
10.1002/acm2.12337
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this work is to investigate the effects of immersing EBT3 radiochromic film in water and to evaluate its contribution to the total uncertainty in dose determination. Materials and methods: We used 3 cm x 3 cm EBT3 radiochromic films irradiated in the range of 0-70 Gy to study the impact of water immersion on the change in net optical density. These films were placed in a water container for a period of 24 h. The net optical density was measured before (0 h) and after of the immersion in water (1, 3, 6, 12, 18, and 24 h). The absorbance spectrum of the EBT3 radiochromic film was measured at 0 h and 24 h after immersion in water. The uncertainty in dose determination due to the effects of keeping the EBT3 radiochromic film submerged in water at 0, 1, and 24 h were recorded in the red, green, and blue channels. Results: We observed an increase in the net optical density as an effect on the film due to its immersion in water. The penetration of the water at the edges of the radiochromic film was observed to be a function of time during which the film remained in the water. On the other hand, the penetration of water at the edges of the film was found to be independent of irradiation dose. Conclusions: EBT3 radiochromic film is found more resistant to water penetration through the edges than its predecessors. However, there is evidence that suggest that liquid water damage the Nylon cover layer of the film by changing its optical properties. Therefore, it is recommended to build a new calibration curve for radiochromic films for a specific situation involving dose measurements in liquid water.
引用
收藏
页码:283 / 290
页数:8
相关论文
共 50 条
  • [21] Precise EBT3 Gafchromic film dosimetry for Grid therapy
    Gholami, Somayeh
    Nedaie, Hassan Ali
    Meigooni, Ali S.
    RADIATION MEASUREMENTS, 2019, 121 : 69 - 76
  • [22] A comprehensive study of the Gafchromic EBT2 radiochromic film. A comparison with EBT
    Andres, C.
    del Castillo, A.
    Tortosa, R.
    Alonso, D.
    Barquero, R.
    MEDICAL PHYSICS, 2010, 37 (12) : 6271 - 6278
  • [23] EBT3 Radiochromic film response in time-dependent thermal environment and water submersion conditions: Its clinical relevance and uncertainty estimation
    Trivedi, Gaurav
    Singh, Pushpendra P.
    Oinam, Arun S.
    RADIATION PHYSICS AND CHEMISTRY, 2025, 227
  • [24] Calibration of the EBT3 Gafchromic Film Using HNN Deep Learning
    Chang, Liyun
    Yeh, Shyh-An
    Ho, Sheng-Yow
    Ding, Hueisch-Jy
    Chen, Pang-Yu
    Lee, Tsair-Fwu
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [25] Dosimetric Investigation of Six Ru-106 Eye Plaques by EBT3 Radiochromic Films and Monte Carlo Simulation
    Arjmand M.
    Ghassemi F.
    Rafiepour P.
    Zeinali R.
    Riazi-Esfahani H.
    Beiki-Ardakani A.
    Journal of Biomedical Physics and Engineering, 2023, 13 (04): : 309 - 316
  • [26] A new analytical model for the response curve in megavoltage photon beams of the radiochromic EBT3 films measured with flatbed scanners
    Rodriguez, Cesar
    Garcia-Pinto, Diego
    Carlos Martinez, Luis
    Lopez-Fernandez, Alfonso
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (08):
  • [27] INVESTIGATION OF EBT3 RADIOCHROMIC FILM RESPONSE IN A HIGH-DOSE RANGE OF 6 MV PHOTON AND 6 MEV ELECTRON BEAMS USING A THREE-COLOR FLATBED SCANNER
    Duruer, Kerem
    Etiz, Durmus
    Yucel, Haluk
    EAST EUROPEAN JOURNAL OF PHYSICS, 2020, (03): : 11 - 18
  • [28] Absolute dose calibration of EBT3 Gafchromic films
    Campajola, L.
    Casolaro, P.
    Di Capua, F.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [29] Dosimetric accuracy of Gafchromic EBT2 and EBT3 film for in vivo dosimetry
    Moylan, Rebecca
    Aland, Trent
    Kairn, Tanya
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (03) : 331 - 337
  • [30] Calibrating page sized Gafchromic EBT3 films
    Crijns, W.
    Maes, F.
    van der Heide, U. A.
    Van den Heuvel, F.
    MEDICAL PHYSICS, 2013, 40 (01)