Real-time in-vivo μ-imaging with Medipix2

被引:22
作者
Dammer, J. [1 ]
Frallicciardi, P. M. [2 ,3 ]
Jakubek, J. [1 ]
Jakubek, M. [1 ]
Pospisil, S. [1 ]
Prenerova, E. [4 ]
Vavrik, D. [1 ]
Volter, L. [5 ]
Weyda, F. [5 ,6 ]
Zemek, R. [5 ]
机构
[1] Czech Tech Univ, Inst Expt & Appl Phys, CZ-12800 Prague 2, Czech Republic
[2] Univ Naples Federico 2, Dept Sci Fis, Naples, Italy
[3] Ist Nazl Fis Nucl, Sez Napoli, I-80125 Naples, Italy
[4] Lab Plant Protect Olesna, CZ-39843 Bernartice U Milevska, Czech Republic
[5] Acad Sci Czech Republic, Inst Entomol, Ctr Biol, CZ-37005 Ceske Budejovice, Czech Republic
[6] Univ S Bohemia, Fac Sci, CZ-37005 Ceske Budejovice, Czech Republic
关键词
X-ray imaging; Digital radiography; Computed tomography (CT); Photon and X-ray detectors;
D O I
10.1016/j.nima.2009.03.154
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An X-ray micro-radiographic system based on the Medipix2 semiconductor pixel detector for dynamic high spatial resolution and for high contrast imaging has been developed. Our system is based on a micro-focus and nano-focus X-ray tube and the hybrid single-photon counting silicon pixel detector Medipix2 (matrix 256 x 256 sq. pixels of 55 mu m pitch). This compact table-top system stands promising as a new tool in the field of small animal imaging as well as in the in-vivo observation of dynamic processes inside living organisms. The main advantages of these Medipix2 pixel detectors include: high sensitivity to low-energy X-ray photons; position sensitive and noiseless single-photon detection with preselected photon energies: single-quantum counting in each pixel performed by digital counter (therefore there is no dark current); digital integration (providing unlimited dynamic range and absolute linearity in device response to number of photons, high sensitivity and high contrast): real-time digital information, high-speed digital communication and data transfer. We improve the picture quality with the help of statistical data analysis and extended the calibration of individual pixels response. 2D and 3D radiographic images of samples demonstrate the potential and applicability of our system for precise in-vivo X-ray high-resolution dynamic diagnostic and biological studies. Obtained results are shown on small animal and organic samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 207
页数:3
相关论文
共 8 条
[1]  
Dammer J, 2007, AIP CONF PROC, V958, P136, DOI 10.1063/1.2825765
[2]  
Hanus R., 2007, J MICROSCOPY, V576, P223
[3]   Data processing and image reconstruction methods for pixel detectors [J].
Jakubek, Jan .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 576 (01) :223-234
[4]   Phase contrast enhanced high resolution X-ray imaging and tomography of soft tissue [J].
Jakubek, Jan ;
Granja, Carlos ;
Dammer, Jiri ;
Hanus, Robert ;
Holy, Tomas ;
Pospisil, Stanislav ;
Tykva, Richard ;
Uher, Josef ;
Vykydal, Zdenek .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) :69-72
[5]   Experimental system for high resolution X-ray transmission radiography [J].
Jakubek, Jan ;
Holy, Tomas ;
Jakubek, Martin ;
Vavrik, Daniel ;
Vykydal, Zdenek .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) :278-281
[6]   Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode [J].
Llopart, X ;
Campbell, M ;
Dinapoli, R ;
Segundo, DS ;
Pemigotti, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2279-2283
[7]  
Weyda F., 2002, Antenna, V26, P249
[8]  
Weyda F., 2006, P 17 CZECH SLOV PLAN, P541