Surface and pore diffusion in macroporous and gel-filled gigaporous stationary phases for protein chromatography

被引:22
作者
Farnan, D [1 ]
Frey, DD [1 ]
Horváth, C [1 ]
机构
[1] Yale Univ, Dept Chem Engn, Mason Lab 205, New Haven, CT 06520 USA
关键词
stationary phases; LC; diffusivity; proteins;
D O I
10.1016/S0021-9673(02)00428-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A recently introduced method [Biotechnol. Prog. 13 (1997) 429] for determining intraparticle mass transfer parameters in high speed liquid chromatography is considered in the present study for the case where the eluite adsorbs onto the stationary phase. The validity of the method was verified theoretically using simulated elution profiles and then applied to experimental data obtained using columns packed with either a macroporous or a gel-filled gigaporous stationary phase. For this purpose, experimental measurements were made using alpha-lactalbumin and bovine serum albumin as eluites at several retention factors. Apparent intraparticle diffusivities measured for the gel-filled gigaporous stationary phase were seen to increase with the retention factor, which indicates that for this material surface diffusion is a significant mechanism of mass transfer under retained conditions. Data obtained on the macroporous stationary phase revealed that the intraparticle diffusivity was independent of the retention factor, which suggests that pore diffusion remains the principal mass transfer mechanism even under conditions where proteins are adsorbed on the column packing. (C) 2002 Published by Elsevier Science B.V.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 22 条
[1]   FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[2]  
ARNOLD FH, 1985, CHEM ENG J, V30, P25
[3]   A BOUNDARY-LAYER MODEL OF FLUID-PARTICLE MASS TRANSFER IN FIXED BEDS [J].
CARBERRY, JJ .
AICHE JOURNAL, 1960, 6 (03) :460-463
[5]   ANALYTIC SOLUTION FOR CHROMATOGRAPHY WITH NONUNIFORM SORBENT PARTICLES [J].
CARTA, G ;
BAUER, JS .
AICHE JOURNAL, 1990, 36 (01) :147-150
[6]   DIFFUSION OF BROWNIAN SPHERES IN SEMIDILUTE POLYMER-SOLUTIONS [J].
CUKIER, RI .
MACROMOLECULES, 1984, 17 (02) :252-255
[7]   APPLICABILITY OF THE EXTERNAL-DIFFUSION MODEL IN ADSORPTION STUDIES [J].
DO, DD ;
RICE, RG .
CHEMICAL ENGINEERING SCIENCE, 1990, 45 (05) :1419-1421
[8]   Intraparticle mass transfer in high-speed chromatography of proteins [J].
Farnan, D ;
Frey, DD ;
Horvath, C .
BIOTECHNOLOGY PROGRESS, 1997, 13 (04) :429-439
[9]   Characterization of protein adsorption by composite silica-polyacrylamide gel anion exchangers .1. Equilibrium and mass transfer in agitated contactors [J].
Fernandez, MA ;
Carta, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 746 (02) :169-183
[10]   Characterization of protein adsorption by composite silica-polyacrylamide gel anion exchangers .2. Mass transfer in packed columns and predictability of breakthrough behavior [J].
Fernandez, MA ;
Laughinghouse, WS ;
Carta, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 746 (02) :185-198