Accuracy and time efficiency for the detection of thoracic cage fractures - Volume rendering compared with transverse computed tomography images

被引:38
作者
Alkadhi, H [1 ]
Wildermuth, S [1 ]
Marincek, B [1 ]
Boehm, T [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, Dept Med Radiol, CH-8091 Zurich, Switzerland
关键词
multidetector-row computed tomography; volume rendering; thoracic cage fractures;
D O I
10.1097/00004728-200405000-00013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare the accuracy and time efficiency of volume rendering (VR) compared with transverse images of multidetector-row computed tomography data to identify thoracic cage fractures. Methods: Computed tomography scans of 50 patients with acute blunt chest trauma were retrospectively analyzed by using VR and transverse images. The number, location, and type of rib and sternal fractures revealed by these viewing methods were compared, and the time needed for diagnosis was measured. Results: Thirty of 50 patients had a total of 178 rib fractures. The mean sensitivity, specificity, and accuracy for their detection were similar for transverse (96%, 100%, and 99%) and VR (98%, 100%, and 100%) images. Three sternal fractures were correctly diagnosed with VR, and I was missed on transverse images by both readers. The time to read VR images (mean of 105 seconds) was significantly reduced compared with the time needed for transverse image reading (mean of 167 seconds; P < 0.001). Conclusion: Volume rendering of computed tomography data depicts thoracic cage fractures with a high accuracy similar to that of transverse images but is considerably faster.
引用
收藏
页码:378 / 385
页数:8
相关论文
共 16 条
[1]   Sternal fractures: Retrospective analysis of 100 cases [J].
Athanassiadi, K ;
Gerazounis, M ;
Moustardas, M ;
Metaxas, E .
WORLD JOURNAL OF SURGERY, 2002, 26 (10) :1243-1246
[2]   Sonography compared with radiography in revealing acute rib fracture [J].
Griffith, JF ;
Rainer, TH ;
Ching, ASC ;
Law, KL ;
Cocks, RA ;
Metreweli, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (06) :1603-1609
[3]  
KUHLMAN JE, 1988, ORTHOPEDICS, V11, P1561
[4]   Skeletal 3-D CT: Advantages of volume rendering over surface rendering [J].
Kuszyk, BS ;
Heath, DG ;
Bliss, DF ;
Fishman, EK .
SKELETAL RADIOLOGY, 1996, 25 (03) :207-214
[5]   Whole-body computed tomography in polytrauma:: techniques and management [J].
Linsenmaier, U ;
Krötz, M ;
Häuser, H ;
Rock, C ;
Rieger, J ;
Bohndorf, K ;
Pfeifer, KJ ;
Reiser, M .
EUROPEAN RADIOLOGY, 2002, 12 (07) :1728-1740
[6]   ADULT ANKLE FRACTURES - COMPARISON OF PLAIN FILMS AND INTERACTIVE 2-DIMENSIONAL AND 3-DIMENSIONAL CT SCANS [J].
MAGID, D ;
MICHELSON, JD ;
NEY, DR ;
FISHMAN, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (05) :1017-1023
[7]   Costal cartilage fractures as revealed on CT and sonography [J].
Malghem, J ;
Vande Berg, BC ;
Lecouvet, FE ;
Maldague, BE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :429-432
[8]   Helical CT in emergency radiology [J].
Novelline, RA ;
Rhea, JT ;
Rao, PM ;
Stuk, JL .
RADIOLOGY, 1999, 213 (02) :321-339
[9]   Three-dimensional volume rendering of multidetector-row CT data:: applicable for emergency radiology [J].
Philipp, MO ;
Kubin, K ;
Mang, T ;
Hörmann, M ;
Metz, VM .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (01) :33-38
[10]   Volume-rendered three-dimensional spiral CT: Musculoskeletal applications [J].
Pretorius, ES ;
Fishman, EK .
RADIOGRAPHICS, 1999, 19 (05) :1143-1160