Impedimetric Aptasensor with Femtomolar Sensitivity Based on the Enlargement of Surface-Charged Gold Nanoparticles

被引:148
作者
Deng, Chunyan [1 ]
Chen, Jinhua [1 ]
Nie, Zhou [1 ]
Wang, Mengdong [1 ]
Chu, Xiaochen [1 ]
Chen, Xiaoli [1 ]
Xiao, Xilin [1 ]
Lei, Chunyang [1 ]
Yao, Shouzhuo [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
ROLLING CIRCLE AMPLIFICATION; IN-VITRO SELECTION; ELECTROCHEMICAL DETECTION; IMPEDANCE SPECTROSCOPY; INSOLUBLE PRODUCT; DNA; REAGENTLESS; PROTEINS; PRECIPITATION; BIOSENSOR;
D O I
10.1021/ac800958a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and ultrasensitive label-free electrochemical impedimetric aptasensor for thrombin based on the cascaded signal amplification was reported. The sandwich system of aptamer/thrombin/aptamer-functionalized Au nanoparticles (Apt-AuNPs) was fabricated as the sensing platform. The change of the interfacial feature of the electrode was characterized by electrochemical impedance analysis with the redox probe [Fe(CN)(6)](3-/4-). For improving detection sensitivity, the three-level cascaded impedimetric signal amplification was developed: (1) Apt-AuNPs as the first-level signal enhancer; (2) the steric-hindrance between the enlarged Apt-AuNPs as the second-level signal amplification; (3) the electrostatic-repulsion between sodium dodecylsulfate (SDS) stabilized Apt-AuNPs and the redox probe [Fe(CN)6]3-/4- as the third-level signal amplification. Enlargement of Apt-AuNPs integrated with negatively charged surfactant (SDS) capping could not only improve the detection sensitivity of the impedimetric aptasensor for thrombin but also present a simple and general signal-amplification model for impedimetric sensor. The aptasensor based on the enlargement of negatively charged Apt-AuNPs showed an increased response of the electron-transfer resistance to the increase of thrombin concentration through a wide detection range from 100 fM to 100 nM. The linear detection range was 0.05-35 nM, and thrombin was easily detectable to a concentration of 100 fM. The aptasensor also has good selectivity and reproducibility.
引用
收藏
页码:739 / 745
页数:7
相关论文
共 44 条
[1]   Chronopotentiometry and Faradaic impedance spectroscopy as signal transduction methods for the biocatalytic precipitation of an insoluble product on electrode supports: routes for enzyme sensors, immunosensors and DNA sensors [J].
Alfonta, L ;
Bardea, A ;
Khersonsky, O ;
Katz, E ;
Willner, I .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (9-12) :675-687
[2]  
BELLE JTL, 2007, ANAL CHEM, V79, P6959
[3]   Label-free protein recognition using an aptamer-based impedance measurement assay [J].
Cai, H ;
Lee, TMH ;
Hsing, IM .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) :433-437
[4]   Aptamer-based biosensors for label-free voltammetric detection of lysozyme [J].
Cheng, Alan K. H. ;
Ge, Bixia ;
Yu, Hua-Zhong .
ANALYTICAL CHEMISTRY, 2007, 79 (14) :5158-5164
[5]   INVITRO SELECTION OF RNA MOLECULES THAT BIND SPECIFIC LIGANDS [J].
ELLINGTON, AD ;
SZOSTAK, JW .
NATURE, 1990, 346 (6287) :818-822
[6]   BLOCKING ORIENTED MONOLAYERS OF ALKYL MERCAPTANS ON GOLD ELECTRODES [J].
FINKLEA, HO ;
AVERY, S ;
LYNCH, M ;
FURTSCH, T .
LANGMUIR, 1987, 3 (03) :409-413
[7]   Selection and analytical applications of aptamers [J].
Hamula, Camille L. A. ;
Guthrie, Jeffrey W. ;
Zhang, Hongquan ;
Li, Xing-Fang ;
Le, X. Chris .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (07) :681-691
[8]   Quantum-dot/aptamer-based ultrasensitive multi-analyte electrochemical biosensor [J].
Hansen, JA ;
Wang, J ;
Kawde, AN ;
Xiang, Y ;
Gothelf, KV ;
Collins, G .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (07) :2228-2229
[9]   Ultrasensitive electrochemical detection of proteins by amplification of aptamer-nanoparticle bio bar codes [J].
He, Pingli ;
Shen, Li ;
Cao, Yunhe ;
Lia, Defa .
ANALYTICAL CHEMISTRY, 2007, 79 (21) :8024-8029
[10]   Aptamer-modified gold nanoparticles for colorimetric determination of platelet-derived growth factors and their receptors [J].
Huang, CC ;
Huang, YF ;
Cao, ZH ;
Tan, WH ;
Chang, HT .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5735-5741