Upgrade of single chamber pacemakers with transvenous leads to dual chamber pacemakers in pediatric and young adult patients

被引:12
作者
Silvetti, MS [1 ]
Drago, F [1 ]
机构
[1] Bambino Gesu Pediat Hosp, Dipartimento Med Chirurg Cardiol Pediat, IRCCS, I-00165 Rome, Italy
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2004年 / 27卷 / 08期
关键词
cardiac pacing; children; endocardial pacing; pacemaker upgrade; pacing complications;
D O I
10.1111/j.1540-8159.2004.00590.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Children with single chamber pacemakers, in adolescence and young adulthood, may be upgraded to dual chamber systems, but there are no published data about indications, timing, and complications. Upgrading was attempted in 18 patients with transvenous pacing leads. A retrospective analysis of all collected data was performed. At initial pacemaker implantation (mean +/- SD, 9.3 +/- 4.1 years), the pacing mode was VVIR (n = 13 patients) and AAI/AAIR (n = 5 patients). After 72 +/- 41 months of follow-up, at the age of 15.5 +/- 5.2 years, upgrade was undertaken because of the patient's age at elective generator replacement (n = 3 patients), ventricular dysfunction (n = 7), syncope/presyncope (n = 3) in patients with VVIR pacing, atrioventricular block (n = 2), and/or drug refractory supraventricular tachyarrhythmias (n = 4) in patients with atrial pacing. In comparison with single chamber pacemaker implantations, the average procedural time and the average fluoroscopy time were not significantly longer. All suitable preexisting leads were incorporated in the new pacing system. Leads were inserted via the ipsiluteral subclavian vein in 16 patients. Venous occlusion was found in two patients: in the first the procedure was not performed; in the second, the contralateral vein was used and the old lead was abandoned. There were no procedural complications. During a follow-up of 14 11 months, ventricular dysfunction worsened in five of seven patients; other patients benefitted symptomatically. In conclusion, pacemaker upgrade is technically challenging but feasible and safe and may be beneficial for some patients.
引用
收藏
页码:1094 / 1098
页数:5
相关论文
共 20 条
[1]   Clinical study of the laser sheath for lead extraction: The total experience in the United States [J].
Byrd, CL ;
Wilkoff, BL ;
Love, CJ ;
Sellers, TD ;
Reiser, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (05) :804-808
[2]   Experience with a low profile bipolar, active fixation pacing lead in pediatric patients [J].
Campbell, RM ;
Raviele, AA ;
Hulse, EJ ;
Auld, DO ;
McRae, GJ ;
Tam, VKH ;
Kanter, KR .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (08) :1152-1157
[3]  
de Voogt WG, 1999, AM J CARDIOL, V83, p187D
[4]   Risk factors for venous obstruction in children with transvenous pacing leads [J].
Figa, FH ;
McCrindle, BW ;
Bigras, JL ;
Hamilton, RM ;
Gow, RM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (08) :1902-1909
[5]  
Friedman RA, 1996, PACE, V19, P778
[6]   Congenital complete atrioventricular block [J].
Friedman, RA ;
Fenrich, AL ;
Kertesz, NJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (11) :1681-1688
[7]  
GILLETTE PC, 1991, PACE, V14, P633
[8]   Ventricular pacemaker upgrade: experience, complications and recommendations [J].
Hildick-Smith, DJR ;
Lowe, MD ;
Newell, SA ;
Schofield, PM ;
Shapiro, LM ;
Stone, DL ;
Grace, AA ;
Petch, MC .
HEART, 1998, 79 (04) :383-387
[9]   Single versus dual chamber pacing in the young: Noninvasive comparative evaluation of cardiac function [J].
Horenstein, MS ;
Karpawich, PP ;
Tantengco, MVT .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (05) :1208-+
[10]   Complications related to permanent pacemaker therapy [J].
Kiviniemi, MS ;
Pirnes, MA ;
Eränen, HJK ;
Kettunen, RVJ ;
Hartikainen, JEK .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (05) :711-720