Reactor core power measurement using Cherenkov radiation and its application in Tehran Research Reactor

被引:14
作者
Arkani, M. [1 ]
Gharib, M. [1 ]
机构
[1] Atom Energy Org Iran, NSTRI, Reactor & Accelerator Res & Dev Sch, Tehran 14395836, Iran
关键词
D O I
10.1016/j.anucene.2009.03.009
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Cherenkov radiation is a process that could be used as an extra channel for power measurement to enhance redundancy and diversity of a reactor. This is especially easy to establish in a pool type research reactor. A simple photo diode array is used in Tehran Research Reactor to measure and display power in parallel with the existing conventional detectors. Experimental measurements on this channel showed that a good linearity exists above 100 kW range. The system has been in use for more than a year and has shown reliability and precision. Nevertheless, the system is subject to further modifications, in particular for application to lower power ranges. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:896 / 900