Comprehensive two-dimensional gas chromatography under high outlet pressure conditions: A new approach to correct the flow-mismatch issue in the two dimensions

被引:9
作者
Peroni, Daniela [1 ]
Janssen, Hans-Gerd [1 ,2 ]
机构
[1] Univ Amsterdam, vant Hoff Inst Mol Sci, Analyt Chem Grp, NL-1090 GD Amsterdam, Netherlands
[2] Unilever R&D Discover Vlaardingen, Adv Measurement & Data Modelling, NL-3130 AC Vlaardingen, Netherlands
关键词
Comprehensive two-dimensional gas; chromatography (GC x GC); Optimum linear velocity; Flow mismatch; Increased outlet pressure; Restrictor;
D O I
10.1016/j.chroma.2014.01.051
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The typical column sets employed in comprehensive two-dimensional gas chromatography (GC x GC) suffer from the impossibility to fully exploit the efficiency of both dimensions simultaneously. Adding a restrictor at the end of the second dimension is a possible approach to adjust the linear velocity profile. Under these high outlet pressure conditions the second dimension becomes much slower while the effect on the primary column is limited. The gap in terms of optimum inlet pressures is thus reduced. A program written in Microsoft Excel (R) was used to calculate the efficiencies of the two dimensions in GC x GC at different outlet pressures. A GC x GC set-up with a restrictor at the end of the second dimension column was successfully installed. Experiments proved that this is a possible way to have a better exploitation of the columns. The chromatograms obtained for a number of applications confirm that the separations achieved at elevated outlet pressure are more efficient than those obtained with the same column set under atmospheric outlet conditions. The price to pay is that the separations become considerably slower. (C) 2014 Elsevier BM. All rights reserved.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 9 条
  • [1] Blumberg LM, 1997, HRC-J HIGH RES CHROM, V20, P597
  • [2] Blumberg LM, 1999, HRC-J HIGH RES CHROM, V22, P403
  • [3] High-speed gas chromatography: an overview of various concepts
    Cramers, CA
    Janssen, HG
    van Deursen, MM
    Leclercq, PA
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) : 315 - 329
  • [4] Giddings J.C., 1965, DYNAMICS CHROMATOGRA
  • [5] INTEGRAL PRESSURE RESTRICTOR FOR CAPILLARY SFC
    GUTHRIE, EJ
    SCHWARTZ, HE
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1986, 24 (06) : 236 - 241
  • [6] Janssen HG, 2009, COMP ANAL C, V55, P123, DOI 10.1016/S0166-526X(09)05506-8
  • [7] Theoretical and practical aspects of fast gas chromatography and method translation
    Klee, MS
    Blumberg, LM
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (05) : 234 - 247
  • [8] Qualitative and quantitative approaches in comprehensive two-dimensional gas chromatography
    Murray, Jacolin A.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1261 : 58 - 68
  • [9] Shellie R, 2004, J SEP SCI, V27, P504