Flexible fiberoptic bronchoscopic removal of a fractured synthetic tracheostomy tube in a 3-year-old child

被引:5
|
作者
Ng, DK [1 ]
Cherk, SW [1 ]
Law, AK [1 ]
机构
[1] Kwong Wah Hosp, Dept Pediat, Hong Kong, Hong Kong, Peoples R China
关键词
flexible fiberoptic bronchoscopy; tracheostomy; foreign body; spinal muscular atrophy;
D O I
10.1002/ppul.10111
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
We report on a 3-year-old boy, who was tracheotomized for prolonged ventilatory support in response to respiratory failure due to spinal muscular atrophy. He aspirated a fractured synthetic tracheostomy tube. It was successfully removed by flexible fiberoptic bronchoscopy. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:141 / 143
页数:3
相关论文
共 4 条
  • [1] Flexible Bronchoscopic Removal of a Fractured Metallic Tracheostomy Tube
    Herrag, Mohammed
    Sajiai, Hafsa
    Rochdi, Youssef
    Lahmiti, Saad
    Dannaoui, Youssra
    Raji, Abdelaziz
    Yazidi, Abdelhaq Alaoui
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2011, 18 (02) : 164 - 167
  • [2] Penetrating transorbital injury by a coloring pencil in a 3-year-old child: A case report
    Huang, Tengyue
    Ling, Jun
    Liu, Ming
    Qiu, Chuanzhen
    Ding, Guanfu
    Huang, Jun
    Krischek, Boris
    Yang, Shaochun
    Zheng, Feng
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019,
  • [3] INADVERTENT REMOVAL OF FOREIGN-BODY VIA A FLEXIBLE FIBEROPTIC BRONCHOSCOPE IN A 4-YEAR-OLD BOY
    AKHTER, J
    GASPAR, M
    BASSUK, A
    ROBERTS, J
    PEDIATRIC PULMONOLOGY, 1994, 18 (01) : 51 - 52
  • [4] Esophagoaortic perforation by foreign body (coin) causing sudden death in a 3-year-old child
    Dahiya, M
    Denton, JS
    AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 1999, 20 (02) : 184 - 188