Numerical analysis of a thermally enhanced domestic hot water tank

被引:44
|
作者
Nabavitabatabayi, Mohammadreza [1 ]
Haghighat, Fariborz [1 ]
Moreau, Alain [2 ]
Sra, Paul [3 ]
机构
[1] Concordia Univ, Dept Bldg Civil & Environm Engn, Montreal, PQ, Canada
[2] Lab Technol Energie Hydro Quebec, Shawinigan, PQ, Canada
[3] Publ Works & Govt Serv Canada, Real Property Branch, Gatineau, PQ, Canada
关键词
Model; PCM; Dispersion of nano-particles; Hot water tank; Load management; Power shifting; PHASE-CHANGE MATERIALS; STORAGE; PERFORMANCE;
D O I
10.1016/j.apenergy.2014.04.081
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Phase change materials (PCMs) have the ability to absorb and release a large amount of thermal energy over the phase transition. This might be an innovative solution to shift the power demand to off peak period and reduce the stress on the electrical grid. Limited research work has been carried out to investigate the impact of PCMs and/or enhanced PCM on the thermal performance of hot water tank. Numerical simulations have been carried out to thoroughly investigate the impact of a number of design and operational parameters on the thermal performance of hot water tank. Although PCMs offer the potential of having higher thermal inertia, the low thermal conductivity squanders that potential. The addition of either pure or enhanced PCMs shifts the power demand to the off-peak periods. This is mainly due to the high thermal inertia of PCMs which keeps the water temperature from plummeting. The simulation results demonstrate that the integration of enhanced PCMs to the hot water tank could shift the power demand to the off-peak for a longer period of time compared to pure PCMs due to the higher thermal conductivity and the enhanced heat transfer rate. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [1] Genetic optimization of a PCM enhanced storage tank for Solar Domestic Hot Water Systems
    Padovan, Roberta
    Manzan, Marco
    SOLAR ENERGY, 2014, 103 : 563 - 573
  • [2] Experimental investigation on the effect of the ratio of tank volume to total capsulized paraffin volume on hot water output for a mantled hot water tank
    Erdemir, Dogan
    Ozbekler, Ahmet
    Altuntop, Necdet
    SOLAR ENERGY, 2022, 239 : 294 - 306
  • [3] Phase change materials in hot water tank for shifting peak power demand
    Nkwetta, Dan Nchelatebe
    Vouillamoz, Pierre-Edouard
    Haghighat, Fariborz
    El Mankibi, Mohamed
    Moreau, Alain
    Desai, Kashyap
    SOLAR ENERGY, 2014, 107 : 628 - 635
  • [4] DOMESTIC HOT WATER STORAGE TANK: DESIGN AND ANALYSIS FOR IMPROVING THERMAL STRATIFICATION
    Devore, Nathan
    Yip, Henry
    Rhee, Jinny
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 10, 2013, : 171 - 178
  • [5] Domestic Hot Water Storage Tank: Design and Analysis for Improving Thermal Stratification
    Devore, Nathan
    Yip, Henry
    Rhee, Jinny
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2013, 135 (04):
  • [6] Design and investigation of single tank phase change thermal storage domestic hot water system
    Mao, Qianjun
    Li, Ying
    Chen, Min
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 25
  • [7] Numerical modeling of latent heat thermal energy storage integrated with heat pump for domestic hot water production
    Inkeri, E.
    Tynjala, T.
    Nikku, M.
    APPLIED THERMAL ENGINEERING, 2022, 214
  • [8] NUMERICAL INVESTIGATION OF THE EFFECT OF THE TANK DIAMETER TO TANK LENGTH RATIO ON THE THERMAL PERFORMANCE OF A HORIZONTAL MANTLED HOT WATER TANK
    Erdemir, Dogan
    HEAT TRANSFER RESEARCH, 2019, 50 (08) : 773 - 797
  • [9] Effect of phase change material on thermal stratification of solar hot water tank with a mantle: A numerical analysis
    Izgi, Burak
    Arslan, Mevluet
    JOURNAL OF ENERGY STORAGE, 2022, 52
  • [10] Experimental validation of a tool for the numerical simulation of a commercial hot water storage tank
    Mongibello, Luigi
    Bianco, Nicola
    Di Somma, Marialaura
    Graditi, Giorgio
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105