MEASUREMENT OF PERSONAL DOSE EQUIVALENT OF X AND GAMMA RADIATION BY RING DOSIMETER: RESULTS OF INTERCOMPARISON MEASUREMENTS

被引:0
|
作者
Adamowicz, Malgorzata [1 ]
Papierz, Sylwia [1 ]
Kacprzyk, Janusz [1 ]
Kaminski, Zbigniew [1 ]
Zmyslony, Marek [1 ]
机构
[1] Nofer Inst Occupat Med, Dept Radiat Protect, PL-91348 Lodz, Poland
关键词
interlaboratory comparisons; X-ray and gamma radiation; personal dose equivalent; ring dosimeter; thermoluminescence detectors;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The aim of the study was to present the results of the interlaboratory comparisons for ring dosimeters and to confirm that the applied method is suitable for measuring the personal dose equivalent H-p(0.07). In addition, calibration procedures used in dosimetric measurements in persons occupationally exposed to ionizing photon radiation X and gamma were presented. Materials and Methods: Ring dosimeters made of flexible plastics with the diameter of approximately 20 mm, equipped with two thermoluminescence (TL) detectors type MTS-N, were the subject of interlaboratory comparisons. Irradiated detectors were red out using a new manual TLD's reader (FIMEL, France). All TLD exposures were done for validation of TLD readers and were performed using the reference X-ray and gamma beams with the ISO rod phantom. The methodology of performed exposures corresponded with the methods applied by the European Radiation Dosimetry Group (EURADOS), the European organizer ofinterlaboratory comparisons. RESULTS: The energy, dose and angular characteristics of the ring dosimeter allowed to elaborate the formula for estimating and verifying the personal dose equivalent H-p(0.07). The test was performed to check and confirm the correctness of the estimated characteristics. The test results were satisfactory, and thus the readiness to implement TLD reader in the used method and to participate in interlaboratory comparisons was confirmed. Conclusions: According to the requirements of the Polish Centre for Accreditation, the laboratory was participating in the interlaboratory comparison organized by EURADOS in terms of the personal dose equivalent H-p(0.07). The result of the comparison was satisfactory, therefore the correctness of the testing procedure was confirmed.
引用
收藏
页码:631 / 637
页数:7
相关论文
共 50 条
  • [1] Intercomparison on measurements of the quantity personal dose equivalent, Hp(0.07), by extremity ring dosimeters in medical fields
    Carinou, E.
    Donadille, L.
    Ginjaume, M.
    Jankowski, J.
    Rimpler, A.
    Merce, A. Sans
    Vanhavere, F.
    Denoziere, M.
    Daures, J.
    Bordy, J. M.
    Itie, C.
    Covens, P.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 565 - 570
  • [2] Ambient dose equivalent measurement with a CsI(Tl) based electronic personal dosimeter
    Park, Kyeongjin
    Kim, Jinhwan
    Lim, Kyung Taek
    Kim, Junhyeok
    Chang, Hojong
    Kim, Hyunduk
    Sharma, Manish
    Cho, Gyuseong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (08) : 1991 - 1997
  • [3] Intercomparison on measurements of the quantity personal dose equivalent Hp(d) in mixed (neutron-gamma) fields -: An IAEA project
    Suarez, R. Cruz
    Schuhmacher, H.
    Pochat, J. L.
    Zimba, Andreas
    Mrabit, K.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 61 - 68
  • [4] MEASUREMENT OF THE EFFECTIVE DOSE EQUIVALENT IN A NUCLEAR-REACTOR ENVIRONMENT WITH A PERSONAL THERMOLUMINESCENT DOSIMETER
    WALSH, ML
    JOHNS, HE
    HEALTH PHYSICS, 1984, 46 (01): : 55 - 64
  • [5] THERMOLUMINESCENCE DOSIMETER FOR PERSONAL DOSE-EQUIVALENT ASSESSMENT
    DASILVA, TA
    DAROSA, LAR
    CAMPOS, LL
    RADIATION PROTECTION DOSIMETRY, 1995, 58 (01) : 17 - 21
  • [6] MEASUREMENT OF THE EFFECTIVE DOSE EQUIVALENT IN A NUCLEAR-REACTOR ENVIRONMENT WITH A PERSONAL THERMOLUMINESCENT DOSIMETER - REPLY
    WALSH, ML
    HEALTH PHYSICS, 1985, 49 (02): : 316 - 317
  • [7] INTERCOMPARISON ON MEASUREMENTS OF THE QUANTITY PERSONAL DOSE EQUIVALENT Hp(10) IN PHOTON FIELDS IN THE AFRICAN REGION
    Msimang, Z.
    Cruz-Suarez, R.
    Zeger, J.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 282 - 286
  • [8] Intercomparison 2013 on measurements of the personal dose equivalent Hp(10) in photon fields in the African region
    Arib, M.
    Herrati, A.
    Dari, F.
    Ma, J.
    Lounis-Mokrani, Z.
    RADIATION PROTECTION DOSIMETRY, 2015, 163 (03) : 276 - 283
  • [9] MEASUREMENT OF THE EFFECTIVE DOSE EQUIVALENT IN A NUCLEAR-REACTOR ENVIRONMENT WITH A PERSONAL THERMOLUMINESCENT DOSIMETER - COMMENT
    SUTHERLAND, JK
    HEALTH PHYSICS, 1985, 49 (02): : 315 - 316
  • [10] RESULTS OF THE IAEA/RCA PERSONAL DOSIMETER INTERCOMPARISON IN THE ASIAN AND PACIFIC REGION
    MURAKAMI, H
    MINAMI, K
    GRIFFITH, RV
    RADIATION PROTECTION DOSIMETRY, 1994, 54 (01) : 19 - 23