Research on reducing radiation exposure for clinical applications of X-ray attenuation

被引:1
作者
Jeon, Min-Cheol [1 ,2 ]
Han, Man-Seok [3 ]
So, Woon-Young [3 ]
Lee, Hyeon-Guck [4 ]
Kim, Yong-Kyun [5 ]
Lee, Seung-Yeol [2 ,6 ]
机构
[1] Chungnam Natl Univ, Dept Radiol, Chungnam Natl Univ Hosp, Taejon 301747, South Korea
[2] Chungnam Natl Univ, Dept Bio Med Engn, Taejon 301747, South Korea
[3] Kangwon Natl Univ, Dept Radiol Sci, Chunchon 220701, South Korea
[4] Eulji Univ Hosp, Dept Radiol, Taejon 302799, South Korea
[5] Daewon Univ Coll, Dept Radiotechnol, Jecheon 390702, South Korea
[6] Minist Food & Drug Safety, Radiat Safety Div, Cheongwon 363700, South Korea
关键词
Radiation exposure; Attenuation; Primary radiation; Secondary (scattered) radiation; Workers;
D O I
10.3938/jkps.64.596
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This study was aimed at identifing areas with low radiation exposure where workers could be taken in the examination room in case that they had to hold the patients by estimating the attenuation of primary radiation and measuring the spatial distribution of scattered radiation. The laboratory equipment included on the X-ray generator, a phantom (human phantom), and a dosimeter. The experiment measured the performance of the examination system (dose reproducibility), the dose of primary radiation (X-rays), and the dose of scattered radiation (secondary radiation). Both the primary and the scattered radiation were attenuated by a factor of tube in vacuum experimental tests of the inverse square law. In this study, the attenuation was 2 similar to 2.246 for primary radiation and 2 similar to 2.105 for secondary radiation. Natural attenuation occurred as the X-rays passed through air, and an attenuation equation was established in this study. The equation for primary radiation (1st dose) was y = A1* exp(-x/t1)+y0. The high-intensity contour of the direction for the cathode was wider than that of the direction for the anode, showing a wide range on the rear side of the cathode and on the rear side of the anode. We tried to find the positions where the workers' radiation exposure could be reduced. When the medical radiation workers have to hold the patient for an abdominal examination, they should be placed towards the tube anode and on the left side of the patient. For a lumbar-spine lateral examination, they should be placed towards the tube anode and behind the patient, and for a femur AP (anterior-posterior) examination, they should be placed towards the tube anode and on the right side of the patient.
引用
收藏
页码:596 / 602
页数:7
相关论文
共 50 条
[41]   Reducing radiation exposure in second-generation cryoballoon ablation without compromising clinical outcome [J].
Marijn J. Holl ;
Rohit E. Bhagwandien ;
Mehran Firouzi ;
Wouter A. de Ruiter ;
Tamas Szili-Torok ;
Sing-Chien Yap .
Journal of Interventional Cardiac Electrophysiology, 2021, 60 :287-294
[42]   Comparison of lead attenuation and lead hardening equivalence of materials used in respect of diagnostic X-ray shielding [J].
Okunade, AA .
APPLIED RADIATION AND ISOTOPES, 2002, 57 (06) :819-824
[43]   X-ray spectra reconstruction from analysis of attenuation data: A Back Scattering Thomson source application [J].
Endrizzi, Marco ;
Delogu, Pasquale ;
Stefanini, Arnaldo .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 608 (01) :S78-S82
[44]   Impact of X-Ray Exposure From Computed Tomography on Wearable Insulin Delivery Devices [J].
Dong, Frank ;
Johnson, Paul ;
Fong, Grant ;
Nguyen, Alex ;
Lauand, Felipe ;
Vienneau, Todd .
JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2024, 18 (06) :1387-1391
[45]   A more accurate and safer method for the measurement of scattered radiation in X-ray examination rooms [J].
Nakamura, Tokiko ;
Shoichi, Suzuki ;
Takei, Yasutaka ;
Kobayashi, Masanao ;
Cruz, Vergil ;
Kobayashi, Ikuo ;
Asegawa, Satoshi ;
Kato, Kyoichi .
RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (01) :69-75
[46]   Development of novel X-ray radiation shielding tiles using cupola furnace slag [J].
Thakur, Krishna Kumar ;
Rahman, Atikur .
EMERGING MATERIALS RESEARCH, 2025, 14 (02) :1-11
[47]   A more accurate and safer method for the measurement of scattered radiation in X-ray examination rooms [J].
Tokiko Nakamura ;
Suzuki Shoichi ;
Yasutaka Takei ;
Masanao Kobayashi ;
Vergil Cruz ;
Ikuo Kobayashi ;
Satoshi Asegawa ;
Kyoichi Kato .
Radiological Physics and Technology, 2020, 13 :69-75
[48]   X-ray radiation shielding and microscopic studies of flexible and moldable bandage by in situ synthesized cerium oxide nanoparticles/MWCNTS nanocomposite for healthcare applications [J].
Verma, Sarika ;
Dhangar, Manish ;
Bajpai, Harsh ;
Chaturvedi, Kamna ;
Mohapatra, Ranjan K. ;
Khan, Mohd. Akram ;
Azam, Mohammad ;
Al-Resayes, Saud I. ;
Srivastava, Avanish Kumar .
RSC ADVANCES, 2023, 13 (13) :8594-8605
[49]   Ultra-short-period WC/SiC multilayer coatings for x-ray applications [J].
Fernandez-Perea, Monica ;
Pivovaroff, Mike J. ;
Soufli, Regina ;
Alameda, Jennifer ;
Mirkarimi, Paul ;
Descalle, Marie-Anne ;
Baker, Sherry L. ;
McCarville, Tom ;
Ziock, Klaus ;
Hornback, Donald ;
Romaine, Suzanne ;
Bruni, Ric ;
Zhong, Zhong ;
Honkimaeki, Veijo ;
Ziegler, Eric ;
Christensen, Finn E. ;
Jakobsen, Anders C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 710 :114-119
[50]   Usefulness of a lead-acrylic shield for reducing lens dose of assistant in x-ray CT examination [J].
Ito, Hajime ;
Matsubara, Kosuke ;
Kobayashi, Ikuo ;
Sakai, Takayuki ;
Isobe, Tomonori ;
Yanagawa, Noriyuki ;
Ochi, Shigehiro .
JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)