Research on reducing radiation exposure for clinical applications of X-ray attenuation

被引:1
作者
Jeon, Min-Cheol [1 ,2 ]
Han, Man-Seok [3 ]
So, Woon-Young [3 ]
Lee, Hyeon-Guck [4 ]
Kim, Yong-Kyun [5 ]
Lee, Seung-Yeol [2 ,6 ]
机构
[1] Chungnam Natl Univ, Dept Radiol, Chungnam Natl Univ Hosp, Taejon 301747, South Korea
[2] Chungnam Natl Univ, Dept Bio Med Engn, Taejon 301747, South Korea
[3] Kangwon Natl Univ, Dept Radiol Sci, Chunchon 220701, South Korea
[4] Eulji Univ Hosp, Dept Radiol, Taejon 302799, South Korea
[5] Daewon Univ Coll, Dept Radiotechnol, Jecheon 390702, South Korea
[6] Minist Food & Drug Safety, Radiat Safety Div, Cheongwon 363700, South Korea
关键词
Radiation exposure; Attenuation; Primary radiation; Secondary (scattered) radiation; Workers;
D O I
10.3938/jkps.64.596
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This study was aimed at identifing areas with low radiation exposure where workers could be taken in the examination room in case that they had to hold the patients by estimating the attenuation of primary radiation and measuring the spatial distribution of scattered radiation. The laboratory equipment included on the X-ray generator, a phantom (human phantom), and a dosimeter. The experiment measured the performance of the examination system (dose reproducibility), the dose of primary radiation (X-rays), and the dose of scattered radiation (secondary radiation). Both the primary and the scattered radiation were attenuated by a factor of tube in vacuum experimental tests of the inverse square law. In this study, the attenuation was 2 similar to 2.246 for primary radiation and 2 similar to 2.105 for secondary radiation. Natural attenuation occurred as the X-rays passed through air, and an attenuation equation was established in this study. The equation for primary radiation (1st dose) was y = A1* exp(-x/t1)+y0. The high-intensity contour of the direction for the cathode was wider than that of the direction for the anode, showing a wide range on the rear side of the cathode and on the rear side of the anode. We tried to find the positions where the workers' radiation exposure could be reduced. When the medical radiation workers have to hold the patient for an abdominal examination, they should be placed towards the tube anode and on the left side of the patient. For a lumbar-spine lateral examination, they should be placed towards the tube anode and behind the patient, and for a femur AP (anterior-posterior) examination, they should be placed towards the tube anode and on the right side of the patient.
引用
收藏
页码:596 / 602
页数:7
相关论文
共 50 条
[31]   Analysis of Patients' X-ray Exposure in 146 Percutaneous Radiologic Gastrostomies [J].
Petersen, Tim-Ole ;
Reinhardt, Martin ;
Fuchs, Jochen ;
Gosch, Dieter ;
Surov, Alexey ;
Stumpp, Patrick ;
Kahn, Thomas ;
Moche, Michael .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2017, 189 (09) :820-827
[32]   X-ray attenuation features of some tellurite glasses evaluated at medical diagnostic energies [J].
Al-Hadeethi, Y. ;
Sayyed, M., I .
APPLIED MATHEMATICS AND COMPUTATION, 2020, 365
[33]   Calculation of air kerma inside the radiation field of X-ray tube [J].
Nazemi, E. ;
Rokrok, B. ;
Movafeghi, A. ;
Dinca, M. ;
Kabir, M. .
RADIATION MEASUREMENTS, 2019, 124 :79-84
[34]   Bismuth and thorium fluorides as efficient X-ray radiation shielding materials [J].
Bukhvalova, Svetlana Yu ;
Asmolova, Nina F. ;
Lopatina, Tatiana, I ;
Bochkarev, Mikhail N. .
RADIATION PHYSICS AND CHEMISTRY, 2021, 182
[35]   Efficacy and User Experience of a Novel X-Ray Shield on Operator Radiation Exposure During Cardiac Catheterization: A Randomized Controlled Trial [J].
Davidsen, Cedric ;
Ytre-Hauge, Kristian ;
Samnoy, Andreas Tefre ;
Vikenes, Kjell ;
Lancellotti, Patrizio ;
Tuseth, Vegard .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (12) :745-753
[36]   Predicting Breast Attenuation in Patients Undergoing Myocardial Perfusion Scintigraphy: A Digital X-Ray Study [J].
Nurkalem, Zekeriya ;
Sahin, Sinan ;
Uslu, Nevzat ;
Emre, Ayse ;
Alper, Ahmet Taha ;
Gorgulu, Sevket ;
Yardi, Fehmi ;
Eren, Mehmet .
JOURNAL OF DIGITAL IMAGING, 2008, 21 (04) :446-451
[37]   Predicting Breast Attenuation in Patients Undergoing Myocardial Perfusion Scintigraphy: A Digital X-Ray Study [J].
Zekeriya Nurkalem ;
Sinan Sahin ;
Nevzat Uslu ;
Ayse Emre ;
Ahmet Taha Alper ;
Sevket Gorgulu ;
Fehmi Yardi ;
Mehmet Eren .
Journal of Digital Imaging, 2008, 21 :446-451
[38]   HEX: a safe research framework for hybrid EMT X-ray navigation [J].
Krumb, Henry J. J. ;
Dorweiler, Bernhard ;
Mukhopadhyay, Anirban .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (07) :1175-1183
[39]   Graphene-based nanocomposites as gamma- and X-ray radiation shield [J].
Filak-Medon, Karolina ;
Fornalski, Krzysztof W. ;
Bonczyk, Michal ;
Jakubowska, Alicja ;
Kempny, Kamila ;
Woloszczuk, Katarzyna ;
Filipczak, Krzysztof ;
Zeranska, Klaudia ;
Zdrojek, Mariusz .
SCIENTIFIC REPORTS, 2024, 14 (01)
[40]   Reducing radiation exposure in second-generation cryoballoon ablation without compromising clinical outcome [J].
Holl, Marijn J. ;
Bhagwandien, Rohit E. ;
Firouzi, Mehran ;
de Ruiter, Wouter A. ;
Szili-Torok, Tamas ;
Yap, Sing-Chien .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (02) :287-294