Research on reducing radiation exposure for clinical applications of X-ray attenuation

被引:1
|
作者
Jeon, Min-Cheol [1 ,2 ]
Han, Man-Seok [3 ]
So, Woon-Young [3 ]
Lee, Hyeon-Guck [4 ]
Kim, Yong-Kyun [5 ]
Lee, Seung-Yeol [2 ,6 ]
机构
[1] Chungnam Natl Univ, Dept Radiol, Chungnam Natl Univ Hosp, Taejon 301747, South Korea
[2] Chungnam Natl Univ, Dept Bio Med Engn, Taejon 301747, South Korea
[3] Kangwon Natl Univ, Dept Radiol Sci, Chunchon 220701, South Korea
[4] Eulji Univ Hosp, Dept Radiol, Taejon 302799, South Korea
[5] Daewon Univ Coll, Dept Radiotechnol, Jecheon 390702, South Korea
[6] Minist Food & Drug Safety, Radiat Safety Div, Cheongwon 363700, South Korea
关键词
Radiation exposure; Attenuation; Primary radiation; Secondary (scattered) radiation; Workers;
D O I
10.3938/jkps.64.596
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This study was aimed at identifing areas with low radiation exposure where workers could be taken in the examination room in case that they had to hold the patients by estimating the attenuation of primary radiation and measuring the spatial distribution of scattered radiation. The laboratory equipment included on the X-ray generator, a phantom (human phantom), and a dosimeter. The experiment measured the performance of the examination system (dose reproducibility), the dose of primary radiation (X-rays), and the dose of scattered radiation (secondary radiation). Both the primary and the scattered radiation were attenuated by a factor of tube in vacuum experimental tests of the inverse square law. In this study, the attenuation was 2 similar to 2.246 for primary radiation and 2 similar to 2.105 for secondary radiation. Natural attenuation occurred as the X-rays passed through air, and an attenuation equation was established in this study. The equation for primary radiation (1st dose) was y = A1* exp(-x/t1)+y0. The high-intensity contour of the direction for the cathode was wider than that of the direction for the anode, showing a wide range on the rear side of the cathode and on the rear side of the anode. We tried to find the positions where the workers' radiation exposure could be reduced. When the medical radiation workers have to hold the patient for an abdominal examination, they should be placed towards the tube anode and on the left side of the patient. For a lumbar-spine lateral examination, they should be placed towards the tube anode and behind the patient, and for a femur AP (anterior-posterior) examination, they should be placed towards the tube anode and on the right side of the patient.
引用
收藏
页码:596 / 602
页数:7
相关论文
共 50 条
  • [1] Research on reducing radiation exposure for clinical applications of X-ray attenuation
    Min-Cheol Jeon
    Man-Seok Han
    Woon-Young So
    Hyeon-Guck Lee
    Yong-Kyun Kim
    Seung-Yeol Lee
    Journal of the Korean Physical Society, 2014, 64 : 596 - 602
  • [2] POLYCHROMATIC X-RAY ATTENUATION CHARACTERISTICS AND WOOD DENSITOMETRY APPLICATIONS
    HOAG, ML
    KRAHMER, RL
    WOOD AND FIBER SCIENCE, 1991, 23 (01): : 23 - 31
  • [3] Radiation exposure in X-ray mammography -: A review.
    Säbel, M
    Aichinger, U
    Schulz-Wendtland, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (02): : 79 - 91
  • [4] Evaluation of X-ray table mattresses for radiation attenuation and impact on image quality
    Alresheedi, N.
    Walton, L.
    Hogg, P.
    Webb, J.
    Tootell, A.
    RADIOGRAPHY, 2021, 27 (01) : 215 - 220
  • [5] A survey on radiation exposure of primary operators from interventional X-ray procedures
    Kong, Yan
    Gao, Linfeng
    Zhuo, Weihai
    Qian, Aijun
    RADIATION MEASUREMENTS, 2013, 55 : 43 - 45
  • [6] Evaluation of a Novel Fascial Dilator Modified with Scale Marker in Percutaneous Nephrolithotomy for Reducing the X-Ray Exposure: A Randomized Clinical Study
    Zeng, Guohua
    Zhao, Zhijian
    Zhong, Wen
    Wu, Kaijun
    Chen, Wenzhong
    Wu, Wenqi
    Xiao, Chenlin
    Liu, Yongda
    JOURNAL OF ENDOUROLOGY, 2013, 27 (11) : 1335 - 1340
  • [7] Steady-State X-Ray Radiation-Induced Attenuation in Canonical Optical Fibers
    De Michele, Vincenzo
    Morana, Adriana
    Campanella, Cosimo
    Vidalot, Jeoffray
    Alessi, Antonino
    Boukenter, Aziz
    Cannas, Marco
    Paillet, Philippe
    Ouerdane, Youcef
    Girard, Sylvain
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2020, 67 (07) : 1650 - 1657
  • [8] Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study
    Haeusler, Uwe
    Czarwinski, Renate
    Brix, Gunnar
    EUROPEAN RADIOLOGY, 2009, 19 (08) : 2000 - 2008
  • [9] Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study
    Uwe Häusler
    Renate Czarwinski
    Gunnar Brix
    European Radiology, 2009, 19 : 2000 - 2008
  • [10] Effectiveness of a Real-Time X-ray Dosimetry Monitor in Reducing Radiation Exposure in Coronary Procedures: The ESPRESSO-Raysafe Randomized Trial
    Olschewski, Maximilian
    Ullrich, Helen
    Brandt, Moritz
    Steven, Sebastian
    Ahoopai, Majid
    Blessing, Recha
    Petrescu, Aniela
    Wenzel, Philip
    Munzel, Thomas
    Gori, Tommaso
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (22)