共 50 条
Novel cation selective exhaustive injection-sweeping procedure for 5-nitroimidazole determination in waters by micellar electrokinetic chromatography using dispersive liquid-liquid microextraction
被引:29
|作者:
Hernandez-Mesa, Maykel
[1
]
Airado-Rodriguez, Diego
[1
]
Cruces-Blanco, Carmen
[1
]
Garcia-Campana, Ana M.
[1
]
机构:
[1] Univ Granada, Fac Sci, Dept Analyt Chem, E-18071 Granada, Spain
关键词:
5-Nitroimidazoles;
Dispersive liquid-liquid microextraction;
Cation selective exhaustive injection;
Sweeping;
Micellar electrokinetic chromatography;
SOLID-PHASE EXTRACTION;
CAPILLARY-ELECTROPHORESIS;
NITROIMIDAZOLE RESIDUES;
MASS-SPECTROMETRY;
DETECTION LIMITS;
METABOLITES;
SAMPLES;
METRONIDAZOLE;
SENSITIVITY;
DIMETRIDAZOLE;
D O I:
10.1016/j.chroma.2014.03.026
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
A novel method consisting of cation-selective exhaustive injection and sweeping (CSEI-sweeping) as on-line preconcentration followed by a micellar electrokinetic chromatography (MEKC) separation has been developed for the determination of 5-nitroimidazoles (5-NDZ) in environmental waters. Moreover, dispersive liquid-liquid microextraction (DLLME) has been proposed for first time as sample treatment technique prior to CSEI-sweeping-MEKC. DLLME was applied to 5 mL of sample. Dibromomethane (1156 mu L) and 2-butanol (1363 mu L) were employed as extractant and dispersive solvents, respectively. Salting-out effect was achieved by the addition of 16% (w/v) NaCl to the samples. After DLLME and organic solvent evaporation, the residue was redissolved in a low conductivity solvent (5 mM phosphoric acid with 5% of methanol) and electrokinetically injected at 9.8 kV for 632 s in a bare fused-silica capillary (57.2 cm, 50 mu m I.D.). Prior to the injection, the capillary was rinsed with 50 mM phosphate buffer pH 2.5, followed by a plug of a higher conductivity buffer (100 mM phosphate pH 2.5, 50 mbar, 264 s) and a plug of water (50 mbar, 2 s). Separation was carried out applying -30 kV at 20 degrees C in 44 mM phosphate buffer pH 2.5, containing 8% tetrahydrofuran and 123 mM sodium dodecyl sulfate. Analytical signals were monitored at 276 nm. Validation was performed in river and well waters, obtaining satisfactory results in terms of linearity, precision (% RSD generally lower than 10%) and trueness (recoveries higher than 70% in almost all cases). LODs ranged from 0.61 to 2.44 ng/mL. The combination of this microextraction technique with the proposed capillary electrophoresis methodology supposes a simple, sensitive and cheap alternative for 5-NDZ analyses, in accordance with the aims of green chemistry. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文