Novel cation selective exhaustive injection-sweeping procedure for 5-nitroimidazole determination in waters by micellar electrokinetic chromatography using dispersive liquid-liquid microextraction

被引:29
|
作者
Hernandez-Mesa, Maykel [1 ]
Airado-Rodriguez, Diego [1 ]
Cruces-Blanco, Carmen [1 ]
Garcia-Campana, Ana M. [1 ]
机构
[1] Univ Granada, Fac Sci, Dept Analyt Chem, E-18071 Granada, Spain
关键词
5-Nitroimidazoles; Dispersive liquid-liquid microextraction; Cation selective exhaustive injection; Sweeping; Micellar electrokinetic chromatography; SOLID-PHASE EXTRACTION; CAPILLARY-ELECTROPHORESIS; NITROIMIDAZOLE RESIDUES; MASS-SPECTROMETRY; DETECTION LIMITS; METABOLITES; SAMPLES; METRONIDAZOLE; SENSITIVITY; DIMETRIDAZOLE;
D O I
10.1016/j.chroma.2014.03.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel method consisting of cation-selective exhaustive injection and sweeping (CSEI-sweeping) as on-line preconcentration followed by a micellar electrokinetic chromatography (MEKC) separation has been developed for the determination of 5-nitroimidazoles (5-NDZ) in environmental waters. Moreover, dispersive liquid-liquid microextraction (DLLME) has been proposed for first time as sample treatment technique prior to CSEI-sweeping-MEKC. DLLME was applied to 5 mL of sample. Dibromomethane (1156 mu L) and 2-butanol (1363 mu L) were employed as extractant and dispersive solvents, respectively. Salting-out effect was achieved by the addition of 16% (w/v) NaCl to the samples. After DLLME and organic solvent evaporation, the residue was redissolved in a low conductivity solvent (5 mM phosphoric acid with 5% of methanol) and electrokinetically injected at 9.8 kV for 632 s in a bare fused-silica capillary (57.2 cm, 50 mu m I.D.). Prior to the injection, the capillary was rinsed with 50 mM phosphate buffer pH 2.5, followed by a plug of a higher conductivity buffer (100 mM phosphate pH 2.5, 50 mbar, 264 s) and a plug of water (50 mbar, 2 s). Separation was carried out applying -30 kV at 20 degrees C in 44 mM phosphate buffer pH 2.5, containing 8% tetrahydrofuran and 123 mM sodium dodecyl sulfate. Analytical signals were monitored at 276 nm. Validation was performed in river and well waters, obtaining satisfactory results in terms of linearity, precision (% RSD generally lower than 10%) and trueness (recoveries higher than 70% in almost all cases). LODs ranged from 0.61 to 2.44 ng/mL. The combination of this microextraction technique with the proposed capillary electrophoresis methodology supposes a simple, sensitive and cheap alternative for 5-NDZ analyses, in accordance with the aims of green chemistry. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 50 条
  • [31] Dispersive liquid-liquid microextraction and solid-phase extraction of polar pesticides from natural water and their determination by micellar electrokinetic chromatography
    V. G. Amelin
    D. S. Bol’shakov
    A. V. Tret’yakov
    Journal of Analytical Chemistry, 2013, 68 : 386 - 397
  • [32] Determination of Nicotine in Tobacco by Chemometric Optimization and Cation-Selective Exhaustive Injection in Combination with Sweeping-Micellar Electrokinetic Chromatography
    Lin, Yi-Hui
    Feng, Chia-Hsien
    Wang, Shih-Wei
    Ko, Po-Yun
    Lee, Ming-Hsun
    Chen, Yen-Ling
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015
  • [33] On-line sample stacking for the analysis of glycyrrhiza flavonoids by anion selective exhaustive injection-sweeping micellar electrokinetic chromatography
    Chen Xin
    Yuan Hongping
    Cao Yuhua
    Chen Qiuyun
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (09) : 889 - 892
  • [34] Analysis of ephedra-alkaloids using sweeping and cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography methods
    Chiang, HY
    Sheu, SJ
    ELECTROPHORESIS, 2004, 25 (4-5) : 670 - 676
  • [35] Analysis of the herbicides paraquat, diquat and difenzoquat in drinking water by micellar electrokinetic chromatography using sweeping and cation selective exhaustive injection
    Núñez, O
    Kim, JB
    Moyano, E
    Galceran, MT
    Terabe, S
    JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (01) : 65 - 75
  • [36] Determination of Ecstasy Components in Human Urine by Gas Chromatography using a Dispersive Liquid-Liquid Microextraction Procedure
    Mashayekhi, Hossein Ali
    Rezaee, Mohammad
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2012, 23 (09) : 1698 - 1703
  • [37] Determination of chlorophenols in water using dispersive liquid-liquid microextraction coupled with water-in-oil microemulsion electrokinetic chromatography in normal stacking mode
    Shi, Ludi
    Wang, Jin
    Feng, Jing
    Zhao, Sihan
    Wang, Zhengmeng
    Tao, Hu
    Liu, Shuhui
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (12) : 2662 - 2670
  • [38] Determination of some sulfonylurea herbicides in soil by a novel liquid-phase microextraction combined with sweeping micellar electrokinetic chromatography
    Shuaihua Zhang
    Xiaofang Yin
    Qian Yang
    Chun Wang
    Zhi Wang
    Analytical and Bioanalytical Chemistry, 2011, 401 : 1071 - 1081
  • [39] Dispersive Liquid–Liquid Microextraction Combined With Micellar Electrokinetic Chromatography for the Determination of Some Photoinitiators in Fruit Juice
    Yaohai Zhang
    Bining Jiao
    Food Analytical Methods, 2015, 8 : 973 - 981
  • [40] Cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography for the analysis of methadone and its metabolites in serum of heroin addicts
    Wang, Chun-Chi
    Chen, Cheng-Chung
    Wang, Shang-Jang
    Wu, Shou-Mei
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (38) : 6832 - 6837