Comparative analysis of renal flow using contrast power Doppler and gray-scale ultrasound

被引:0
|
作者
Sehgal, CM
Arger, PH
Bovee, KC
Pugh, CR
Kirchofer, JI
机构
来源
PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES - MEDICAL IMAGING 1997 | 1997年 / 3033卷
关键词
D O I
10.1117/12.274046
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our previous studies have shown that renal perfusion can be visualized by imaging the transit of a contrast agent through the parenchyma of the organ using gray scale (GS) and power Doppler (PD) ultrasound. However, the relative merits and the sensitivities of the two imaging methods are not known. This study compares the effectiveness of the two modes in visualizing kidney perfusion at the clinical dose of contrast agents. Gray scale and power Doppler images of the dog kidneys (N = 5) were recorded using a clinical ultrasound scanner at 4-7 MHz. A fixed longitudinal plane of the kidney was imaged by mounting the transducer on the animal with a specially designed holder. A dose of 0.1 ml/kg of Echogen (Sonus Pharmaceuticals, Costa Mesa, CA) was injected intravenously and GS and PD images were recorded simultaneously on two separate time-encoded video tapes during the passage of the contrast agent through the kidneys. The enhancement of GS and PD images was assessed qualitatively by three radiologists. The quantitative assessment was made by measuring the regional and global enhancements of digitized B-scan and PD images. Regional measurements were made by comparing brightness of the post contrast images with that of a pre-contrast reference image pixel by pixel. Student t-test (p less than or equal to 0.01) was used to determine the statistical significance of the change. The regions representing statistically significant differences were encoded on the image in color with brightness proportional to the magnitude of change. The regions with no significant change were represented in gray scale. This generated a series of new images, referred to as StatMap, with color representing regions of perfusion. Changes in power Doppler images were visually detectable with high confidence in all five dogs by all three radiologists. There was no perceptible changes in B-scans. Computer analysis of PD images yielded characteristic indicator dilution curves in all five dogs with an initial rise time of 2-5 sec and a peak at 7-20 sec. The enhancement in PD lasted for 97-400 seconds. The peak to pre-injection Doppler power ratio was 2.41 +/- 0.85. There were no detectable changes in gray scale images except in one dog which exhibited a small change (similar to 2% of the base line value). The StatMap images of PD exhibited perfusion over the entire kidney, whereas the GS images showed perfusion to be sparsely distributed. The qualitative and quantitative analyses show PD to be more sensitive to contrast enhancement than B-scan imaging, making the former more suitable for visualizing renal perfusion.
引用
收藏
页码:209 / 214
页数:6
相关论文
共 50 条
  • [2] Gray-Scale and Power Doppler Ultrasound Findings Predictive of Cubital Tunnel Syndrome Severity
    Lee, Tony Y.
    Dy, Christopher J.
    Ray, Wilson Z.
    Colorado, Berdale S.
    Brogan, David M.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2024, 19 (03): : 392 - 399
  • [3] CEREBELLAR AND SPINAL HEMANGIOBLASTOMAS - EVALUATION WITH INTRAOPERATIVE GRAY-SCALE AND COLOR DOPPLER FLOW ULTRASOUND
    AVILA, NA
    SHAWKER, TH
    CHOYKE, PL
    OLDFIELD, EH
    RADIOLOGY, 1993, 188 (01) : 143 - 147
  • [4] Color Doppler and gray-scale ultrasound evaluation of the postpartum uterus
    Van den Bosch, T
    Van Schoubroeck, D
    Lu, C
    De Brabanter, J
    Van Huffel, S
    Timmerman, D
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2002, 20 (06) : 586 - 591
  • [5] Contrast-enhanced ultrasonography compared to gray-scale and power doppler in the diagnosis of peripheral lymphadenopathy
    Slaisova, Radka
    Benda, Karel
    Jarkovsky, Jiri
    Petrasova, Hana
    Szturz, Petr
    Valek, Vlastimil
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (04) : 693 - 698
  • [6] FOLLOW-UP-STUDY OF RENAL-TRANSPLANTS BY DUPLEX DOPPLER AND GRAY-SCALE ULTRASOUND
    JANSEN, O
    ROB, PM
    SCHMIDTKE, V
    MARIENHOFF, N
    RINAST, E
    WEISS, HD
    EUROPEAN JOURNAL OF RADIOLOGY, 1992, 15 (01) : 26 - 31
  • [7] Gray Scale Ultrasound, Color Doppler Ultrasound, and Contrast-Enhanced Ultrasound in Renal Parenchymal Diseases
    Quaia, Emilio
    Correas, Jean Michel
    Mehta, Maithili
    Murchison, John T.
    Gennari, Antonio Giulio
    van Beek, Edwin J. R.
    ULTRASOUND QUARTERLY, 2018, 34 (04) : 250 - 267
  • [8] Gray-scale, Doppler and contrast-enhanced ultrasound in pancreatic allograft surveillance: A systematic literature review
    Morelli, Luca
    Guadagni, Simone
    Gianardi, Desiree
    Furbetta, Niccolo
    Di Franco, Gregorio
    Palmeri, Matteo
    Bianchini, Matteo
    Pisano, Roberta
    Borrelli, Valerio
    Campatelli, Alessandro
    Mosca, Franco
    Di Candio, Giulio
    TRANSPLANTATION REVIEWS, 2019, 33 (03) : 166 - 172
  • [9] Using gray-scale and color and power Doppler sonography to detect prostatic cancer
    Halpern, EJ
    Strup, SE
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (03) : 623 - 627
  • [10] Contribution of power Doppler and gray-scale ultrasound of the median nerve in evaluation of carpal tunnel syndrome
    Mohamed, Rania E.
    Amin, Mohamed A.
    Aboelsafa, Ashraf A.
    Elsayed, Salwa E.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (01): : 191 - 201