CFRP strengthening for punching shear of interior slab-column connections

被引:33
|
作者
Sharaf, Mohamed H.
Soudki, Khaled A. [1 ]
Van Dusen, Michael
机构
[1] Univ Waterloo, Dept Civil Engn, Waterloo, ON N2L 3G1, Canada
[2] Halsall Associates Ltd, Toronto, ON M4P 1E4, Canada
关键词
Concrete slabs; Concrete; reinforced; Fiber reinforced polymers; Reinforcement; Shear;
D O I
10.1061/(ASCE)1090-0268(2006)10:5(410)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the results of an experimental investigation studying the effect of retrofitting interior slab-column connections against punching shear failure with externally bonded carbon fiber reinforced polymer (CFRP) strips. Six full-scale, 2000 mm-square x 150-mm-thick slab specimens were constructed. The effect of varying the CFRP strengthening amount and configuration on the load-carrying capacity of the slab specimens was investigated. Specimens were supported along their edges and tested to failure. Strengthened slabs showed an increase in stiffness between 29 and 60% and in punching capacity between 6 and 16% with respect to the control unstrengthened slab. An analytical model was refined to predict the punching shear capacity of the specimens strengthened with CFRP strips. The model takes into account both the configuration and amount of CFRP strips. The proposed model shows good agreement with the experimental results.
引用
收藏
页码:410 / 418
页数:9
相关论文
共 50 条
  • [31] Punching shear capacity of RC slab-CFT column connections
    Chen, Cheng-Cheng
    Giduquio, Marnie B.
    Chang, Shih-Chieh Liu
    Cheng, Min-Yuan
    ENGINEERING STRUCTURES, 2020, 218 (218)
  • [32] Retrofit of slab column interior connections using shear bolts
    Adetifa, B
    Polak, MA
    ACI STRUCTURAL JOURNAL, 2005, 102 (02) : 268 - 274
  • [33] Experimental study on punching shear behavior of hollow floor slab-column reinforced connection
    Pang, Rui
    Dang, Longji
    Ni, Hongmei
    Liang, Shuting
    Li, Qianqian
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (07) : 1531 - 1543
  • [34] Effects of high temperature on residual punching strength of slab-column connections after cooling and enhanced post-punching load resistance
    Zhang, Chunyu
    Ma, Wenchen
    Liu, Xiang
    Tian, Ying
    Orton, Sarah L.
    ENGINEERING STRUCTURES, 2019, 199
  • [35] Evaluation of Steel Fiber Reinforcement for Punching Shear Resistance in Slab-Column Connections-Part II: Lateral Displacement Reversals
    Cheng, Min-Yuan
    Parra-Montesinos, Gustavo J.
    ACI STRUCTURAL JOURNAL, 2010, 107 (01) : 110 - 118
  • [36] Punching shear tests and design of UHTCC-enhanced RC slab-column joints with shear reinforcements
    Yu, Zhe-Xin
    Tong, Gen-Shu
    Tong, Jing-Zhong
    Huang, Xiao-Ning
    Li, Qing-Hua
    Xu, Shi-Lang
    MAGAZINE OF CONCRETE RESEARCH, 2024, 76 (19) : 1106 - 1120
  • [37] Finite element analysis of interior slab-column connections strengthened by steel angle plates
    Taresh, Hussein R.
    Yatim, Mohd Yazmil Md
    Azmi, Mohd Reza
    STRUCTURAL CONCRETE, 2021, 22 (02) : 676 - 690
  • [38] Rehabilitation of reinforced concrete slab-column connections
    El-Salakawy, EF
    Polak, MA
    Soudki, KA
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2002, 29 (04) : 602 - 611
  • [39] Punching shear of slab- column connections with beams attached to one or two sides
    Sharaky, Said T.
    El Salam, Adel Abd
    Nafie, Amr
    Al Kersh, Mohamad A.
    STRUCTURES, 2023, 57
  • [40] Improving predictive accuracy for punching shear strength in fiber-reinforced polymer concrete slab-column connections via robust deep learning
    Babiker, Ammar
    Abbas, Yassir M.
    Khan, Mohammad Iqbal
    Khatib, Jamal M.
    STRUCTURES, 2024, 70