Comparative Evaluation of Foveal Avascular Zone on Two Optical Coherence Tomography Angiography Devices

被引:10
|
作者
Dave, Prachi A. [1 ]
Dansingani, Kunal K. [2 ]
Jabeen, Ayesha [3 ]
Jabeen, Asiya [3 ]
Ali, M. Hasnat [3 ]
Vupparaboina, Kiran Kumar [3 ]
Peguda, Hari Kumar [3 ]
Pappurru, Rajeev Reddy [3 ]
Agrawal, Rupesh [4 ]
Chhablani, Jay [3 ]
机构
[1] Dr Shroffs Char Eye Hosp, New Delhi, India
[2] Univ Nebraska Med Ctr, Truhlsen Eye Inst, Omaha, NE USA
[3] Srimati Kanuri Santhamma Ctr Vitreo Retinal Dis, LV Prasad Eye Inst, KAR Campus, Hyderabad, Telangana, India
[4] Tan Tock Seng Hosp, Natl Healthcare Grp, Eye Inst, Singapore, Singapore
关键词
DIABETIC-RETINOPATHY; QUANTIFICATION; AREA;
D O I
10.1097/OPX.0000000000001238
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE: This study compares foveal avascular zone (FAZ) geometry in healthy eyes as imaged by two commercially available optical coherence tomography angiography (OCTA) devices. Foveal avascular zone measurements are repeatable and reproducible with each OCTA device, but interdevice agreement was poor. We provide conversion factors between devices. PURPOSE: The purpose of this study was to perform comparative evaluation of FAZ geometry in healthy eyes as imaged by two commercially available OCTA devices. METHODS: Ninety-six eyes of 48 healthy subjects were imaged prospectively on each of two OCTA devices (DRI-OCT [Topcon Corporation, Tokyo, Japan]; Cirrus 5000 [Carl Zeiss Meditec Inc., Dublin, CA]). The FAZ was evaluated in the superficial capillary plexus layer of 6 x 6-mm foveal scans by two masked observers. Intraobserver and interobserver agreement was determined using intraclass correlation by using linear mixed models and Bland-Altman plots. K-means clustering was used to provide conversion values between two devices. Foveal avascular zone acircularity was calculated using scans from each device and compared. RESULTS: The intraobserver repeatability for DRI-OCT was 0.95 (95% confidence interval [CI], 0.90 to 0.98) for observer A and 0.92 (95% CI, 0.83 to 0.96) for observer B. Intraobserver repeatability for Cirrus 5000 was 0.988 (95% CI, 0.972 to 0.995) for observer A and 0.993 (95% CI, 0.983 to 0.997) for observer B. The interobserver variability between observers A and B for DRI-OCT was 0.87 (0.73 to 0.94) and for Cirrus 5000 was 0.984 (95% CI, 0.964 to 0.993). Poor interdevice agreement (0.205 [95% CI, -0.202 to 0.554]) was noted, and conversion formulas were devised to convert FAZ area measurements from one device to another. No significant correlation was found when comparing FAZ acircularity indices between devices (P = .39). CONCLUSIONS: Repeatable and reproducible FAZ area measurements were obtained with each respective OCTA device, but interdevice agreement was poor, yet quantifiable and systematic with calculable conversion factors between devices.
引用
收藏
页码:602 / 607
页数:6
相关论文
共 50 条
  • [31] An Optical Coherence Tomography Angiography Study of the Relationship Between Foveal Avascular Zone Size and Retinal Vessel Density
    Kwon, Junki
    Choi, Jaewan
    Shin, Joong Won
    Lee, Jiyun
    Kook, Michael S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (10) : 4143 - 4153
  • [32] Interocular symmetry of the foveal avascular zone area in healthy eyes: a swept-source optical coherence tomography angiography study
    Liu, Mengxuan
    Fujiwara, Atsushi
    Morizane, Yuki
    Kawasaki, Ryo
    Kimura, Shuhei
    Morizane-Hosokawa, Mio
    Shiode, Yusuke
    Hirano, Masayuki
    Doi, Shinichiro
    Toshima, Shinji
    Takahashi, Kosuke
    Hosogi, Mika
    Ma, Xiang
    Shiraga, Fumio
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2020, 64 (02) : 171 - 179
  • [33] The quantitative measurements of choroidal thickness and volume in diabetic retinopathy using optical coherence tomography and optical coherence tomography angiography; correlation with vision and foveal avascular zone
    Fariba Ghassemi
    Sahar Berijani
    Ameneh Babeli
    Houshang Faghihi
    Alireza Gholizadeh
    Siamak Sabour
    BMC Ophthalmology, 22
  • [34] The quantitative measurements of choroidal thickness and volume in diabetic retinopathy using optical coherence tomography and optical coherence tomography angiography; correlation with vision and foveal avascular zone
    Ghassemi, Fariba
    Berijani, Sahar
    Babeli, Ameneh
    Faghihi, Houshang
    Gholizadeh, Alireza
    Sabour, Siamak
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [35] Factors affecting foveal avascular zone in healthy eyes: An examination using swept source optical coherence tomography angiography
    Fujiwara, Atsushi
    Morizane, Yuki
    Hosokawa, Mio
    Kimura, Shuhei
    Shiode, Yusuke
    Hirano, Masayuki
    Doi, Shinichiro
    Toshima, Shinji
    Takahashi, Kosuke
    Hosogi, Mika
    Shiraga, Fumio
    PLOS ONE, 2017, 12 (11):
  • [36] Alterations of the Foveal Avascular Zone Measured by Optical Coherence Tomography Angiography in Glaucoma Patients With Central Visual Field Defects
    Kwon, Junki
    Choi, Jaewan
    Shin, Joong Won
    Lee, Jiyun
    Kook, Michael S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (03) : 1637 - 1645
  • [37] Improved Automated Foveal Avascular Zone Measurement in Cirrus Optical Coherence Tomography Angiography Using the Level Sets Macro
    Lin, Aidi
    Fang, Danqi
    Li, Cuilian
    Cheung, Carol Y.
    Chen, Haoyu
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (12): : 1 - 10
  • [38] Analysis of foveal avascular zone by using spectral-domain optical coherence tomography angiography in healthy Indian eyes
    Gupta, Priyadarshi
    Thakar, Meenakshi
    Rajurkar, Ketaki
    Jaisingh, Kirti
    Shaw, Ekta
    Dipu, Taw Anne
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (06) : 838 - 843
  • [39] Evaluation of foveal avascular zone changes in patients with type 1 diabetes using optical coherence topography angiography
    El Din, Eman F. S.
    Ahmed, Essam E. D. S.
    Bayoumy, Ahmed S. M.
    Ahmed, Marwa El Sayed
    Gad, Elham A. El Azim
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (04) : 259 - 264
  • [40] Automatic segmentation of foveal avascular zone based on adaptive watershed algorithm in retinal optical coherence tomography angiography images
    Liu, Jian
    Yan, Shixin
    Lu, Nan
    Yang, Dongni
    Fan, Chunhui
    Lv, Hongyu
    Wang, Shuanglian
    Zhu, Xin
    Zhao, Yuqian
    Wang, Yi
    Ma, Zhenhe
    Yu, Yao
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2022, 15 (01)