Accuracy of CT-guided biopsies in 359 patients with musculoskeletal lesions

被引:174
作者
Hau, MA
Kim, JI
Kattapuram, S
Hornicek, FJ
Rosenberg, AE
Gebhardt, MC
Mankin, HJ [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Orthopaed Surg,Oncol Serv, Boston, MA 02114 USA
[2] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Radiol, Boston, MA 02114 USA
[3] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Pathol, Boston, MA 02114 USA
关键词
biopsy; needle; bone; soft tissue; tumor; accuracy;
D O I
10.1007/s00256-002-0474-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The study was undertaken to assess the diagnostic accuracy and clinical usefulness of computed tomography (CT)-guided biopsies and fine needle aspirates of musculoskeletal lesions. The analysis compared the accuracy according to anatomical location, size, type of lesion, and histology. On the basis of the information obtained by reviewing the report of the CT biopsy and comparing it with the final diagnosis for 359 cases, the overall accuracy was determined to be 71%. The accuracy for 101 fine needle aspirations was 63% and for 258 CT-guided core biopsies was 74%. It is of note that the biopsies of 81 pelvic lesions had higher rates of diagnostic accuracy (81%) than those of 278 non-pelvic sites (68%), and especially 94 lesions of the spine (61%). The lowest success rates occurred in 26 patients with infectious diseases (50%). We conclude that these procedures remain the logical and safe choice for diagnostic studies of patients with lesions of the musculoskeletal system.
引用
收藏
页码:349 / 353
页数:5
相关论文
共 35 条
[1]  
BARTH RJ, 1992, SURGERY, V112, P536
[2]  
Bickels J, 1999, CLIN ORTHOP RELAT R, P212
[3]  
BRUGIERES P, 1991, J NEURORADIOLOGY, V18, P351
[4]   EFFECT OF BIOPSY-HOLE SHAPE AND SIZE ON BONE STRENGTH [J].
CLARK, CR ;
MORGAN, C ;
SONSTEGARD, DA ;
MATTHEWS, LS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (02) :213-217
[5]  
DENHEETEN GJ, 1985, J SURG ONCOL, V28, P247
[6]  
DESANTOS LA, 1979, CANCER, V43, P735, DOI 10.1002/1097-0142(197902)43:2<735::AID-CNCR2820430250>3.0.CO
[7]  
2-H
[8]   Accuracy of CT-guided needle biopsy of musculoskeletal neoplasms [J].
Dupuy, DE ;
Rosenberg, AE ;
Punyaratabandhu, T ;
Tan, MH ;
Mankin, HJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) :759-762
[9]   FINE-NEEDLE ASPIRATION BIOPSY OF BONE [J].
ELKHOURY, GY ;
TEREPKA, RH ;
MICKELSON, MR ;
RAINVILLE, KL ;
ZALESKI, MS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1983, 65 (04) :522-525
[10]   NEEDLE BIOPSY IN THE CLINICAL DIAGNOSIS OF TUMOURS [J].
ELLIS, F .
BRITISH JOURNAL OF SURGERY, 1947, 34 (135) :240-261