EVALUATION OF SIMPLE AND LOOPED SUTURE AND NEW MATERIAL FOR FLEXOR TENDON REPAIR

被引:19
作者
Brockardt, C. J. [1 ]
Sullivan, L. G. [1 ]
Watkins, B. E. [1 ]
Wongworawat, M. D. [1 ]
机构
[1] Loma Linda Univ, Dept Orthopaed Surg, Loma Linda, CA 92354 USA
关键词
tendon repair; suture; looped; Fiberwire; Kessler; cruciate; BIOMECHANICAL EVALUATION; GAP FORMATION; CORE SUTURES; STRENGTH; RESISTANCE;
D O I
10.1177/1753193408097319
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Flexor tendon repair strength is proportional to the number of suture strands crossing the repair site but it is not clear if each strand needs to result from a separate pass through the tendon. We examined whether one throw of looped suture across a repair site equals two separate throws of suture and whether fewer passes with stronger material such as Fiberwire is equivalent to more passes with a comparatively weaker material such as Supramid. When evaluating the repairs for force required to generate a 2 mm gap and for gap formed at the instant prior to failure, looped suture cannot substitute for two separate passes of suture (Supramid Kessler looped vs. separate passes, 14 N vs. 35 N and 8.8 mm vs. 4.1 mm, respectively; Fiberwire Kessler looped vs. separate passes, 25 N vs. 43 N and 7.6 mm vs. 4.6 mm, respectively; all p < 0.05). Two-stranded Fiberwire Kessler repair equalled four-stranded cruciate repair with Supramid for all tested parameters (force at 2 mm gap: 17 N vs. 22 N, respectively; force at failure: 42 N vs. 46 N; and gap formed prior to instant of failure: 6.9 mm vs. 5.6 mm; ail p > 0.05).
引用
收藏
页码:329 / 332
页数:4
相关论文
共 16 条
[1]   Comparative biomechanical performances of 4-strand core suture repairs for zone II flexor tendon lacerations [J].
Angeles, JG ;
Heminger, H ;
Mass, DP .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (03) :508-517
[2]  
AOKI M, 1995, CLIN ORTHOP RELAT R, P205
[3]   COMPARISON OF A SUTURE TECHNIQUE WITH THE MODIFIED KESSLER METHOD - RESISTANCE TO GAP FORMATION [J].
BARMAKIAN, JT ;
LIN, H ;
GREEN, SM ;
POSNER, MA ;
CASAR, RS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (05) :777-781
[4]   Biomechanical evaluation of a four-strand modification of the Tang method of tendon repair [J].
Cao, Y ;
Tang, JB .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2005, 30B (04) :374-378
[5]   Effect of peripheral suture depth on strength of tendon repairs [J].
Diao, E ;
Hariharan, JS ;
Soejima, O ;
Lotz, JC .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (02) :234-239
[6]   The effect of gap formation at the repair site on the strength and excursion of intrasynovial flexor tendons - An experimental study on the early stages of tendon-healing in dogs [J].
Gelberman, RH ;
Boyer, MI ;
Brodt, MD ;
Winters, SC ;
Silva, MJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (07) :975-982
[7]  
IONA LE, 1997, BR J PLAST SURG, V50, P236
[8]   A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair [J].
Lawrence, TA ;
Davis, TRC .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04) :836-841
[9]  
McLarney E, 1999, J HAND SURG-AM, V24A, P295
[10]   Flexor tendon repairs: The impact of fiberwire on grasping and locking core sutures [J].
Miller, Brian ;
Dodds, Seth D. ;
deMars, Adam ;
Zagoreas, Niko ;
Waitayawinyu, Thanapong ;
Trumble, Thomas E. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (05) :591-596