Effect of Coronal Alignment on 10-Year Survivorship of a Single Contemporary Total Knee Arthroplasty

被引:14
作者
Tibbo, Meagan E. [1 ]
Limberg, Afton K. [1 ]
Perry, Kevin I. [1 ]
Pagnano, Mark W. [1 ]
Stuart, Michael J. [1 ]
Hanssen, Arlen D. [1 ]
Abdel, Matthew P. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55905 USA
关键词
mechanical axis; coronal alignment; total knee arthroplasty; survivorship; MECHANICAL AXIS ALIGNMENT; ROBOTIC TOTAL KNEE; FOLLOW-UP; FUNCTIONAL OUTCOMES; SURVIVAL; PROSTHESIS; IMPLANT; HIP;
D O I
10.3390/jcm10010142
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Debate remains regarding the utility of mechanical axis alignment as a predictor of durability after total knee arthroplasty (TKA). Our study aimed to assess the effects of coronal alignment on implant durability, clinical outcomes, and radiographic results with a single fixed-bearing TKA design. All patients undergoing primary cemented TKA of a single design (Stryker Triathlon) from 2005-2007 with >10 years of follow-up and available pre-operative and post-operative hip-knee-ankle radiographs were included (n = 89). Radiographs were measured to determine coronal alignment and assessed for loosening. Mean preoperative mechanical axis alignment was -6 degrees +/- 6.7 degrees (varus, range, -16 degrees-23 degrees), while mean post-operative alignment was -1 degrees +/- 2.7 degrees (varus, range, -3 degrees-15 degrees). The aligned group was defined as knees with a post-operative mechanical axis of 0 degrees +/- 3 degrees (n = 73) and the outlier group as those outside this range (n = 16). No patients underwent revision. Ten-year survivorship free from any reoperation was 99% and 100% in the aligned and outlier groups, respectively (p = 0.64). Knee Society scores improved significantly in both groups (p < 0.001) and did not differ at final follow-up (p = 0.15). No knees demonstrated radiographic evidence of loosening. Post-operative mechanical axis alignment within 3 degrees of neutral was not associated with improved implant durability, clinical outcomes, or radiographic results at 10 years following primary TKA.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [31] Inverse kinematic total knee arthroplasty using conventional instrumentation restores constitutional coronal alignment
    Keyes, Sarah
    Russell, Shane P.
    Bertalan, Zsolt
    Harty, James A.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (12) : 3210 - 3219
  • [32] The Impact of Coronal Plane Alignment on Polyethylene Wear and Damage in Total Knee Arthroplasty: A Retrieval Study
    Vandekerckhove, Pieter-Jan T. K.
    Teeter, Matthew G.
    Naudie, Douglas D. R.
    Howard, James L.
    MacDonald, Steven J.
    Lanting, Brent A.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (06) : 2012 - 2016
  • [33] Clinical results and 10-year survivorship of the Synthes Epoca resurfacing total shoulder arthroplasty
    James Karssiens, Timothy
    Zhou, Rui
    Ritchie Gill, James
    Paul Roberts, Christopher
    [J]. SHOULDER & ELBOW, 2022, 14 (06) : 615 - 624
  • [34] Clinical performance and survivorship of navigated floating platform mobile-bearing total knee arthroplasty: A minimum 10-year follow-up
    Kim, Sang-Min
    Seo, Jai-Gon
    Lim, Seung-Jae
    Lim, Hyung-Tae
    Cho, Chang-Ho
    Moon, Young-Wan
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2017, 13 (03)
  • [35] Coronal alignment classes after robotic-assisted total knee arthroplasty are not associated with variation in patient- reported outcome measurements: A single-center cohort study
    Kaneko, Takao
    Yamamoto, Ayakane
    Takada, Kazutaka
    Yoshizawa, Shu
    [J]. KNEE, 2023, 41 : 274 - 282
  • [36] Hindfoot alignment at one year after total knee arthroplasty
    Takenaka, Takashi
    Ikoma, Kazuya
    Ohashi, Suzuyo
    Arai, Yuji
    Hara, Yusuke
    Ueshima, Keiichiro
    Sawada, Koushiro
    Shirai, Toshiharu
    Fujiwara, Hiroyoshi
    Kubo, Toshikazu
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) : 2442 - 2446
  • [37] Effect of Femoral Resection on Coronal Overall Alignment after Conventional Total Knee Arthroplasty
    Zhao, Min-Wei
    Wang, Lu
    Zeng, Lin
    Hu, Yu-Qing
    Hu, Jin-Xin
    Tian, Hua
    [J]. CHINESE MEDICAL JOURNAL, 2016, 129 (21) : 2535 - 2539
  • [38] Biomechanical Effect of Coronal Alignment and Ligament Laxity in Total Knee Arthroplasty: A Simulation Study
    Ro, Jaehun
    Ro, Du Hyun
    Kang, Yeokyung
    Han, Hyuk-Soo
    Shin, Choongsoo S.
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [39] Survivorship of Metaphyseal Sleeves in Revision Total Knee Arthroplasty
    Chalmers, Brian P.
    Desy, Nicholas M.
    Pagnano, Mark W.
    Trousdale, Robert T.
    Taunton, Michael J.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (05) : 1565 - 1570
  • [40] CompressA® Knee Arthroplasty Has 80% 10-year Survivorship and Novel Forms of Bone Failure
    Healey, John H.
    Morris, Carol D.
    Athanasian, Edward A.
    Boland, Patrick J.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (03) : 774 - 783