Effect of Coronal Alignment on 10-Year Survivorship of a Single Contemporary Total Knee Arthroplasty

被引:14
作者
Tibbo, Meagan E. [1 ]
Limberg, Afton K. [1 ]
Perry, Kevin I. [1 ]
Pagnano, Mark W. [1 ]
Stuart, Michael J. [1 ]
Hanssen, Arlen D. [1 ]
Abdel, Matthew P. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55905 USA
关键词
mechanical axis; coronal alignment; total knee arthroplasty; survivorship; MECHANICAL AXIS ALIGNMENT; ROBOTIC TOTAL KNEE; FOLLOW-UP; FUNCTIONAL OUTCOMES; SURVIVAL; PROSTHESIS; IMPLANT; HIP;
D O I
10.3390/jcm10010142
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Debate remains regarding the utility of mechanical axis alignment as a predictor of durability after total knee arthroplasty (TKA). Our study aimed to assess the effects of coronal alignment on implant durability, clinical outcomes, and radiographic results with a single fixed-bearing TKA design. All patients undergoing primary cemented TKA of a single design (Stryker Triathlon) from 2005-2007 with >10 years of follow-up and available pre-operative and post-operative hip-knee-ankle radiographs were included (n = 89). Radiographs were measured to determine coronal alignment and assessed for loosening. Mean preoperative mechanical axis alignment was -6 degrees +/- 6.7 degrees (varus, range, -16 degrees-23 degrees), while mean post-operative alignment was -1 degrees +/- 2.7 degrees (varus, range, -3 degrees-15 degrees). The aligned group was defined as knees with a post-operative mechanical axis of 0 degrees +/- 3 degrees (n = 73) and the outlier group as those outside this range (n = 16). No patients underwent revision. Ten-year survivorship free from any reoperation was 99% and 100% in the aligned and outlier groups, respectively (p = 0.64). Knee Society scores improved significantly in both groups (p < 0.001) and did not differ at final follow-up (p = 0.15). No knees demonstrated radiographic evidence of loosening. Post-operative mechanical axis alignment within 3 degrees of neutral was not associated with improved implant durability, clinical outcomes, or radiographic results at 10 years following primary TKA.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
[31]   The accuracy of component alignment in custom cutting blocks compared with, conventional total knee arthroplasty instrumentation: Prospective control trial [J].
Chotanaphuti, Thanainit ;
Wangwittayakul, Visit ;
Khuangsirikul, Saradej ;
Foojareonyos, Trakul .
KNEE, 2014, 21 (01) :185-188
[32]   Clinical Results and Survivorship of the GENESIS II Total Knee Arthroplasty at a Minimum of 15 Years [J].
McCalden, Richard W. ;
Hart, Gavin P. ;
MacDonald, Steven J. ;
Naudie, Douglas D. ;
Howard, James H. ;
Bourne, Robert B. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (07) :2161-2166
[33]   Inverse kinematic total knee arthroplasty using conventional instrumentation restores constitutional coronal alignment [J].
Keyes, Sarah ;
Russell, Shane P. ;
Bertalan, Zsolt ;
Harty, James A. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (12) :3210-3219
[34]   The Impact of Coronal Plane Alignment on Polyethylene Wear and Damage in Total Knee Arthroplasty: A Retrieval Study [J].
Vandekerckhove, Pieter-Jan T. K. ;
Teeter, Matthew G. ;
Naudie, Douglas D. R. ;
Howard, James L. ;
MacDonald, Steven J. ;
Lanting, Brent A. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (06) :2012-2016
[35]   Clinical results and 10-year survivorship of the Synthes Epoca resurfacing total shoulder arthroplasty [J].
James Karssiens, Timothy ;
Zhou, Rui ;
Ritchie Gill, James ;
Paul Roberts, Christopher .
SHOULDER & ELBOW, 2022, 14 (06) :615-624
[36]   Clinical performance and survivorship of navigated floating platform mobile-bearing total knee arthroplasty: A minimum 10-year follow-up [J].
Kim, Sang-Min ;
Seo, Jai-Gon ;
Lim, Seung-Jae ;
Lim, Hyung-Tae ;
Cho, Chang-Ho ;
Moon, Young-Wan .
INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2017, 13 (03)
[37]   Coronal alignment classes after robotic-assisted total knee arthroplasty are not associated with variation in patient- reported outcome measurements: A single-center cohort study [J].
Kaneko, Takao ;
Yamamoto, Ayakane ;
Takada, Kazutaka ;
Yoshizawa, Shu .
KNEE, 2023, 41 :274-282
[38]   Effect of Femoral Resection on Coronal Overall Alignment after Conventional Total Knee Arthroplasty [J].
Zhao, Min-Wei ;
Wang, Lu ;
Zeng, Lin ;
Hu, Yu-Qing ;
Hu, Jin-Xin ;
Tian, Hua .
CHINESE MEDICAL JOURNAL, 2016, 129 (21) :2535-2539
[39]   Hindfoot alignment at one year after total knee arthroplasty [J].
Takenaka, Takashi ;
Ikoma, Kazuya ;
Ohashi, Suzuyo ;
Arai, Yuji ;
Hara, Yusuke ;
Ueshima, Keiichiro ;
Sawada, Koushiro ;
Shirai, Toshiharu ;
Fujiwara, Hiroyoshi ;
Kubo, Toshikazu .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (08) :2442-2446
[40]   Biomechanical Effect of Coronal Alignment and Ligament Laxity in Total Knee Arthroplasty: A Simulation Study [J].
Ro, Jaehun ;
Ro, Du Hyun ;
Kang, Yeokyung ;
Han, Hyuk-Soo ;
Shin, Choongsoo S. .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10