Promoting meconium clearance from the lungs of the neonatal piglet with asymmetric high frequency oscillation

被引:9
作者
Patrinos, ME
Balaraman, V
Ku, T
Meister, J
Rubin, BK
Stenzler, A
Easa, D
机构
[1] KAPIOLANI MED CTR,CLIN RES CTR,DEPT PEDIAT,HONOLULU,HI 96826
[2] UNIV HAWAII,JOHN A BURNS SCH MED,HONOLULU,HI 96826
[3] CARDINAL GLENNON MEM HOSP CHILDREN,DEPT PEDIAT,ST LOUIS,MO 63104
[4] ST LOUIS UNIV,CTR HLTH SCI,ST LOUIS,MO 63104
[5] SENSORMED CORP,YORBA LINDA,CA 92887
关键词
LIQUID FLOW MECHANISM; BRONCHIAL-SECRETIONS; ASPIRATION SYNDROME; MUCUS CLEARANCE; TRANSPORT; MODEL; VENTILATION; REMOVAL;
D O I
10.1203/00006450-199709000-00015
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
To investigate the role of high frequency oscillation (HFO) in promoting meconium clearance from the airway, we used a commercially available ventilator configured with maximal expiratory flow exceeding inspiratory flow (asymmetric HFO or AHFO). We hypothesized that AHFO would move meconium in an expiratory direction (toward the ventilator). We first tested our hypothesis in vitro and, later, in vivo using the neonatal piglet. In vitro experiments using a Plexiglas airway confirmed meconium movement in an expiratory direction when bias ratio was greater than or equal to 2. For in vivo experiments, each piglet received a 3 mL/kg intratracheal bolus of a 44 g/100 mL meconium mixture followed by 45 min of mechanical ventilation. Then, in part 1, the piglet was placed in a 15 degrees head down tilt position and randomized to either AHFO [ratio of inspiratory time/expiratory time (I:E) of 70:30] or HFO (I:E ratio of 30:70). After 30 min of either AHFO or HFO, the piglet was crossed over to the alternate strategy for an additional 30 min. For part 2, we maintained the piglet on either AHFO or HFO continuously for 4 h. Results demonstrate that, although there was a tendency for larger volumes of meconium to be aspirated from the airway during AHFO in part 1 experiments, there was no difference found in part 2. We also found no significant differences in blood gases or hemodynamic measurements between AHFO and HFO during the prolonged observation period in part 2 of our study. We conclude that AHFO is of no benefit in the treatment of meconium aspiration syndrome.
引用
收藏
页码:342 / 347
页数:6
相关论文
共 17 条
[1]   REMOVAL OF BRONCHIAL-SECRETIONS BY 2-PHASE GAS-LIQUID TRANSPORT [J].
BENJAMIN, RG ;
CHAPMAN, GA ;
KIM, CS ;
SACKNER, MA .
CHEST, 1989, 95 (03) :658-663
[2]   REMOVING MECONIUM FROM INFANT TRACHEAS - WHAT WORKS BEST [J].
BENT, RC ;
WISWELL, TE ;
CHANG, A .
AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1992, 146 (09) :1085-1089
[3]   MUCUS TRANSPORT BY HIGH-FREQUENCY NONSYMMETRICAL OSCILLATORY AIR-FLOW [J].
CHANG, HK ;
WEBER, ME ;
KING, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 65 (03) :1203-1209
[4]   CARDIORESPIRATORY EFFECTS OF CHANGING INSPIRATORY TO EXPIRATORY RATIO DURING HIGH-FREQUENCY OSCILLATION IN AN ANIMAL-MODEL OF RESPIRATORY-FAILURE [J].
COURTNEY, SE ;
WEBER, KR ;
SPOHN, WA ;
BENDER, CV ;
MALIN, SW ;
GOTSHALL, RW .
PEDIATRIC PULMONOLOGY, 1992, 13 (02) :113-116
[5]   DIFFERENTIAL-EFFECTS OF OXYGEN AND BAROTRAUMA ON LUNG INJURY IN THE NEONATAL PIGLET [J].
DAVIS, JM ;
DICKERSON, B ;
METLAY, L ;
PENNEY, DP .
PEDIATRIC PULMONOLOGY, 1991, 10 (03) :157-163
[6]  
EASA D, 1993, PEDIATR RES, V33, P365
[7]  
Findlay RD, 1996, PEDIATRICS, V97, P48
[8]   REMOVAL OF EXCESSIVE BRONCHIAL-SECRETIONS BY ASYMMETRIC HIGH-FREQUENCY OSCILLATIONS [J].
FREITAG, L ;
LONG, WM ;
KIM, CS ;
WANNER, A .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (02) :614-619
[9]   INCREASE IN MUCOCILIARY CLEARANCE IN NORMAL MAN INDUCED BY ORAL HIGH-FREQUENCY OSCILLATION [J].
GEORGE, RJD ;
JOHNSON, MA ;
PAVIA, D ;
AGNEW, JE ;
CLARKE, SW ;
GEDDES, DM .
THORAX, 1985, 40 (06) :433-437
[10]   CRITERIA FOR MUCUS TRANSPORT IN THE AIRWAYS BY 2-PHASE GAS-LIQUID FLOW MECHANISM [J].
KIM, CS ;
RODRIGUEZ, CR ;
ELDRIDGE, MA ;
SACKNER, MA .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (03) :901-907