Determination of pyridoxal in human serum by matrix isopotential synchronous fluorescence spectrometry

被引:5
|
作者
Nevado, JJB
Pulgarin, JAM
Laguna, MAG
机构
[1] Dept. of Analyt. Chem. and Foods T., University of Castilla-La Mancha
关键词
pyridoxal; human serum; matrix isopotential synchronous fluorescence spectrometry;
D O I
10.1016/0731-7085(96)01780-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of pyridoxal in human serum was performed using a fluorimetric technique that is useful for the determination of compounds in samples with unknown background fluorescence, based on synchronous scans through a trajectory joining points of equal intensity of a fluorescence matrix three-dimensional spectrum. This technique, called matrix isopotential synchronous fluorescence can be improved by means of the application of derivatives. The determination of pyridoxal in human serum was performed with this technique without any prior separation steps. The validity, applicability and simplicity of the method were demonstrated. The measurements were performed in aqueous medium at pH 7.0 adjusted by adding 0.05 M phosphate buffer solution. A complete statistical analysis of the experimental data was performed and the results showed that correlation coefficients are between 0.9901 and 0.9958 for all the calibration graphs, and in all cases the intercepts on the ordinate were negligible. The experimental F (1.72) is smaller than theoretical value (3.89) as expected from an analysis of variance. The reproducibility of the method was tested and the results were a standard deviation of 0.0117 mu g ml(-1) and a relative error of 4.91%.
引用
收藏
页码:1487 / 1494
页数:8
相关论文
共 50 条
  • [31] Simultaneous determination of aspirin and salicyclic acid by synchronous fluorescence spectrometry
    Wei, YF
    Li, XH
    Ma, DM
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (04) : 588 - 590
  • [32] Determination of Isoliquiritigenin and Its Distribution in Mice by Synchronous Fluorescence Spectrometry
    Han, Bo
    Chen, Wen
    Zheng, Qiusheng
    Wang, Xinchun
    Yan, Huan
    Li, Le
    Aisa, Hajakber
    ANALYTICAL SCIENCES, 2011, 27 (11) : 1115 - 1119
  • [33] Simultaneous determination of salicylamide and salsalate in serum and urine by first derivative variable-angle synchronous fluorescence spectrometry
    Pulgarín, JAM
    Bermejo, LFG
    ANALYTICAL BIOCHEMISTRY, 1998, 265 (02) : 331 - 339
  • [34] Determination of human albumin in serum and urine samples by constant-energy synchronous fluorescence method
    Madrakian, Tayyebeh
    Bagheri, Habibollah
    Afkhami, Abbas
    LUMINESCENCE, 2015, 30 (05) : 576 - 582
  • [35] DETERMINATION OF IRON IN SERUM BY ATOMIC FLUORESCENCE FLAME SPECTROMETRY
    RIPPETOE, WE
    MUSCAT, VI
    VICKERS, TJ
    ANALYTICAL CHEMISTRY, 1974, 46 (06) : 796 - 796
  • [36] Determination of Amaranth in cocktail by synchronous three-dimensional fluorescence spectrometry
    Zhu, Chun
    Song, Xin-Shu
    Zhu, Cong-Hai
    Chen, Guo-Qing
    Zhu, Tuo
    MODERN PHYSICS LETTERS B, 2018, 32 (34-36):
  • [37] Determination of trace amounts of anthracene in phenanthrene by derivative synchronous fluorescence spectrometry
    Furusawa, M
    Tachibana, M
    Sugime, S
    Sakurai, S
    NIPPON KAGAKU KAISHI, 1998, (03) : 211 - 214
  • [38] Investigation of the interaction between N,N′-di(4-chlorophenyl)thiourea and human serum albumin by fluorescence spectroscopy:: Synchronous fluorescence determination of human serum albumin
    Cui, Feng-Ling
    Wang, Jun-Li
    Cui, Yan-Rui
    Li, Jian-Ping
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (02) : 533 - 539
  • [39] Second-derivative synchronous fluorescence spectroscopy for the simultaneous determination of naproxen and salicylic acid in human serum
    Konstantianos, DG
    Ioannou, PC
    ANALYST, 1996, 121 (07) : 909 - 912
  • [40] SIMULTANEOUS DETERMINATION OF CEPHRADINE AND CEPHALEXIN IN SERUM BY DERIVATIVE SYNCHRONOUS FLUORESCENCE SPECTROSCOPY
    IZQUIERDO, P
    GUTIERREZ, MC
    GOMEZHENS, A
    PEREZBENDITO, D
    ANALYTICAL LETTERS, 1990, 23 (03) : 487 - 505