Biomechanical comparison of medial sustainable nail and proximal femoral nail antirotation in the treatment of an unstable intertrochanteric fracture

被引:27
|
作者
Nie, S. [1 ]
Li, M. [1 ]
Ji, H. [2 ,3 ,4 ]
Li, Z. [1 ]
Li, W. [1 ]
Zhang, H. [1 ]
Licheng, Z. [1 ]
Tang, P. [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Orthopaed, Beijing, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Beijing, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Dept Anesthesia, Beijing, Peoples R China
[4] Chinese Peoples Liberat Army Gen Hosp, Operat Ctr, Beijing, Peoples R China
来源
BONE & JOINT RESEARCH | 2020年 / 9卷 / 12期
关键词
Unstable intertrochanteric fracture; Biomechanical; Cephalomedullary nail; CEPHALOMEDULLARY NAIL; FEMUR FRACTURES; HIP-FRACTURES; AUGMENTATION;
D O I
10.1302/2046-3758.912.BJR-2020-0284.R1
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Aims Restoration of proximal medial femoral support is the keystone in the treatment of intertrochanteric fractures. None of the available implants are effective in constructing the medial femoral support. Medial sustainable nail (MSN-II) is a novel cephalomedullary nail designed for this. In this study, biomechanical difference between MSN-II and proximal femoral nail anti-rotation (PFNA-II) was compared to determine whether or not MSN-II can effectively reconstruct the medial femoral support. Methods A total of 36 synthetic femur models with simulated intertrochanteric fractures without medial support (AO/OTA 31-A2.3) were assigned to two groups with 18 specimens each for stabilization with MSN-II or PFNA-II. Each group was further divided into three subgroups of six specimens according to different experimental conditions respectively as follows: axial loading test; static torsional test; and cyclic loading test. Results The mean axial stiffness, vertical displacement, and maximum failure load of MSN-II were 258.47 N/mm (SD 42.27), 2.99 mm (SD 0.56), and 4,886 N (SD 525.31), respectively, while those of PFNA-II were 170.28 N/mm (SD 64.63), 4.86 mm (SD 1.66), and 3,870.87 N (SD 552.21), respectively. The mean torsional stiffness and failure torque of MSN-II were 1.72 N m/degrees (SD 0.61) and 16.54 N m (SD 7.06), respectively, while those of PFNA-II were 0.61 N m/degrees (SD 0.39) and 6.6 N m (SD 6.65), respectively. The displacement of MSN-II in each cycle point was less than that of PFNA-II in cyclic loading test. Significantly higher stiffness and less displacement were detected in the MSN-II group (p < 0.05). Conclusion The biomechanical performance of MSN-II was better than that of PFNA-II, suggesting that MSN-II may provide more effective mechanical support in the treatment of unstable intertrochanteric fractures.
引用
收藏
页码:840 / 847
页数:8
相关论文
共 50 条
  • [1] BIOMECHANICAL STUDY ON PROXIMAL FEMORAL NAIL ANTIROTATION (PFNA) FOR INTERTROCHANTERIC FRACTURE
    Wang, Lizhen
    Zhao, Feng
    Han, Jingyun
    Wang, Chao
    Fan, Yubo
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2012, 12 (04)
  • [2] A comparative biomechanical study of proximal femoral nail (InterTAN) and proximal femoral nail antirotation for intertrochanteric fractures
    Yanfeng Huang
    Chunlin Zhang
    Yi Luo
    International Orthopaedics, 2013, 37 : 2465 - 2473
  • [3] Comparison of proximal femoral nail antirotation and total hip arthroplasty in the treatment of femoral intertrochanteric fracture
    Li, Xuejun
    Xu, Jian
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2022, 38 (04) : 1016 - 1020
  • [4] A comparative biomechanical study of proximal femoral nail (InterTAN) and proximal femoral nail antirotation for intertrochanteric fractures
    Huang, Yanfeng
    Zhang, Chunlin
    Luo, Yi
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (12) : 2465 - 2473
  • [5] A comparison between proximal femoral nail antirotation (PFNA) and inter Tan nail for the surgical treatment of unstable intertrochanteric fracture: A case series
    Chen Guobin
    Yu Cui
    Zhao Maoquan
    Xiao Qishu
    ASIAN JOURNAL OF SURGERY, 2021, 44 (08) : 1095 - 1096
  • [6] The Asia proximal femoral nail antirotation versus the standard proximal femoral antirotation nail for unstable intertrochanteric fractures in elderly Chinese patients
    Li, J.
    Cheng, L.
    Jing, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (02) : 143 - 146
  • [7] MANAGEMENT OF UNSTABLE INTERTROCHANTERIC FRACTURE BY PROXIMAL FEMORAL NAIL
    Yadav, Sidharth
    Golhar, Anil V.
    Agrawal, Ritul
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (15): : 4084 - 4102
  • [8] A novel intramedullary nail design of intertrochanteric fracture fixation improved by proximal femoral nail antirotation
    She, Ze
    Yang, Fan
    Zhang, Siyuan
    Yang, Liang
    Wang, Xin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2023,
  • [9] A comparison of the InterTan nail and proximal femoral fail antirotation in the treatment of reverse intertrochanteric femoral fractures
    Imerci, Ahmet
    Aydogan, Nevres H.
    Tosun, Kursad
    ACTA ORTHOPAEDICA BELGICA, 2018, 84 (02): : 123 - 131
  • [10] Biomechanical evaluation of a new intramedullary nail compared with proximal femoral nail antirotation and InterTAN for the management of femoral intertrochanteric fractures
    Wang, Chaofeng
    Duan, Ning
    Li, Zhong
    Ma, Teng
    Zhang, Kun
    Wang, Qian
    Huang, Qiang
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12