Utility of Bruch membrane opening-based optic nerve head parameters in myopic subjects

被引:25
作者
Sastre-Ibanez, Marina [1 ,2 ,3 ]
Martinez-de-la-Casa, Jose M. [1 ,2 ,3 ]
Rebolleda, Gema [4 ]
Cifuentes-Canorea, Pilar [1 ,2 ,3 ]
Nieves-Moreno, Maria [1 ,2 ,3 ]
Morales-Fernandez, Laura [1 ,2 ,3 ]
Saenz-Frances, Federico [1 ,2 ,3 ]
Garcia-Feijoo, Julian [1 ,2 ,3 ]
机构
[1] San Carlos Clin Hosp, Dept Ophthalmolgy, Madrid, Spain
[2] Univ Complutense Madrid, Dept Ophthalmol, Fac Med, Madrid, Spain
[3] San Carlos Clin Hosp IdISSC, Hlth Res Inst, Madrid, Spain
[4] Ramon & Cajal Hosp, Dept Ophthalmolgy, Madrid, Spain
关键词
Bruch membrane opening; Myopia; Optic nerve head; Optical coherence tomography; Retinal nerve fiber layer; FIBER LAYER MEASUREMENTS; VISUAL-FIELD DEFECTS; COHERENCE TOMOGRAPHY; GLAUCOMA; THICKNESS; DISC;
D O I
10.5301/ejo.5001022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate whether the new rim analysis software with spectral-domain optical coherence tomography (SD-OCT) shows advantages over the retinal nerve fiber layer (RNFL) thickness in patients with moderate myopia. Methods: In this prospective cross-sectional study, we studied 65 healthy subjects, 37 with spherical refractive errors in the range of -3 to -6 D (moderate, G1) and 28 with less than -3 D (low/non-myopic, G0). All patients were examined with Heidelberg Spectralis SD-OCT, including Glaucoma Premium Module Edition (GPME) software. With GPME, we analyzed the neuroretinal rim (Bruch membrane opening-minimum rim width [BMO-MRW]) and RNFL. Results: The average age of subjects was 30.2 +/- 9.3 years for G0 and 29.9 +/- 7.1 years for G1 (p = 0.903). Mean sphere was -0.5 +/- 0.3 D (-1.25 to 0 D) G0 and -3.9 +/- 0.3 D (-6.00 to -3 D) G1 (p<0.001). The RNFL thickness comparison between G0 and G1 showed a significantly lower thickness in G1 (p = 0.018). The BMO-MRW measurements were similar in both groups (p = 0.331). With the BMO-MRW examination, the number of sectors classified as pathologic per subject in G1 were significantly lower compared to RNFL analysis (p = 0.023). Conclusions: Ring analysis based on BMO-MRW measurements shows a lower rate of false-positives compared to RNFL thickness when studying healthy moderate myopic eyes and it would be advisable to take this into consideration when analyzing these patients.
引用
收藏
页码:42 / 46
页数:5
相关论文
共 21 条
[1]  
Airakinsen P J., 1996, The Glaucomas (Basic Sciences), V1, P617
[2]   Sensitivity and specificity of the StratusOCT for perimetric glaucoma [J].
Budenz, DL ;
Michael, A ;
Chang, RT ;
McSoley, J ;
Katz, J .
OPHTHALMOLOGY, 2005, 112 (01) :3-9
[3]   From Clinical Examination of the Optic Disc to Clinical Assessment of the Optic Nerve Head: A Paradigm Change [J].
Chauhan, Balwantray C. ;
Burgoyne, Claude F. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (02) :218-227
[4]   Enhanced Detection of Open-angle Glaucoma with an Anatomically Accurate Optical Coherence Tomography-Derived Neuroretinal Rim Parameter [J].
Chauhan, Balwantray C. ;
O'Leary, Neil ;
AlMobarak, Faisal A. ;
Reis, Alexandre S. C. ;
Yang, Hongli ;
Sharpe, Glen P. ;
Hutchison, Donna M. ;
Nicolela, Marcelo T. ;
Burgoyne, Claude F. .
OPHTHALMOLOGY, 2013, 120 (03) :535-543
[5]  
Chen Teresa C, 2009, Trans Am Ophthalmol Soc, V107, P254
[6]   OPTIC DISK MORPHOMETRY IN HIGH MYOPIA [J].
JONAS, JB ;
GUSEK, GC ;
NAUMANN, GOH .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1988, 226 (06) :587-590
[7]   Effect of Myopia on the Thickness of the Retinal Nerve Fiber Layer Measured by Cirrus HD Optical Coherence Tomography [J].
Kang, Shin Hee ;
Hong, Seung Woo ;
Im, Seong Kyu ;
Lee, Sang Hyup ;
Ahn, Myung Douk .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (08) :4075-4083
[8]  
Katz J, 1997, INVEST OPHTH VIS SCI, V38, P334
[9]   Retinal nerve fiber layer measurements in myopia: An optical coherence tomography study [J].
Leung, Christopher Kai-Shun ;
Mohamed, Shaheeda ;
Leung, King Sai ;
Cheung, Carol Yim-Lui ;
Chan, Sylvia Lai-wa ;
Cheng, Daphne Ka-yee ;
Lee, August Ki-cheung ;
Leung, Gloria Yuk-oi ;
Rao, Srinivas Kamalakara ;
Lam, Dennis Shun Chiu .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (12) :5171-5176
[10]   Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography A Variability and Diagnostic Performance Study [J].
Leung, Christopher Kai-shun ;
Cheung, Carol Yim-lui ;
Weinreb, Robert N. ;
Qiu, Quanliang ;
Liu, Shu ;
Li, Haitao ;
Xu, Guihua ;
Fan, Ning ;
Huang, Lina ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2009, 116 (07) :1257-1263