Using a constrained formulation based on probability summation to fit receiver operating characteristic (ROC) curves

被引:0
作者
Swensson, RG [1 ]
King, JL [1 ]
Good, WF [1 ]
Gur, D [1 ]
机构
[1] Univ Pittsburgh, Dept Radiol, Pittsburgh, PA 15261 USA
来源
MEDICAL IMAGING 2000: IMAGE PERCEPTION AND PERFORMANCE | 2000年 / 3981卷
关键词
ROC curves; ROC analysis; accuracy; observer performance; detection; localization;
D O I
10.1117/12.383102
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A constrained ROC formulation from probability summation is proposed for measuring observer ;performance in detecting abnormal findings on medical images. This assumes the observer's detection or rating decision on each image is determined by a latent variable that characterizes the specific finding (type and location) considered most likely to be a target abnormality. For positive cases, this "maximum-suspicion" variable is assumed to be either the value for the actual target or for the most suspicious non-target finding, whichever is the greater (more suspicious). Unlike the usual ROC formulation, this constrained formulation guarantees a "well-behaved" ROC curve that always equals or exceeds chance-level decisions and cannot exhibit an upward "hook." Its estimated parameters specify the accuracy for separating positive from negative cases, and they also predict accuracy in locating or identifying the actual abnormal findings. The present maximum-likelihood procedure [runs on PC with Windows 95 or NT] fits this constrained formulation to rating-ROC data using normal distributions with two free parameters. Fits of the conventional and constrained ROC formulations are compared for continuous and discrete-scale ratings of chest films in a variety of detection problems, both for localized lesions (nodules, rib fractures) and for diffuse abnormalities (interstitial disease, infiltrates or pneumothorax). The two fitted ROC curves are nearly identical unless the conventional ROC has an ill behaved "hook," below the constrained ROC.
引用
收藏
页码:145 / 153
页数:9
相关论文
共 19 条
[1]   SATISFACTION OF SEARCH IN DIAGNOSTIC-RADIOLOGY [J].
BERBAUM, KS ;
FRANKEN, EA ;
DORFMAN, DD ;
ROOHOLAMINI, SA ;
KATHOL, MH ;
BARLOON, TJ ;
BEHLKE, FM ;
SATO, Y ;
LU, CH ;
ELKHOURY, GY ;
FLICKINGER, FW ;
MONTGOMERY, WJ .
INVESTIGATIVE RADIOLOGY, 1990, 25 (02) :133-140
[2]  
BUNCH PC, 1977, P SOC PHOTO-OPT INS, V127, P124
[3]   FREE-RESPONSE METHODOLOGY - ALTERNATE ANALYSIS AND A NEW OBSERVER-PERFORMANCE EXPERIMENT [J].
CHAKRABORTY, DP ;
WINTER, LHL .
RADIOLOGY, 1990, 174 (03) :873-881
[4]   MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA [J].
DORFMAN, DD ;
ALF, E .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) :487-&
[5]   Proper receiver operating characteristic analysis: The bigamma model [J].
Dorfman, DD ;
Berbaum, KS ;
Metz, CE ;
Lenth, RV ;
Hanley, JA ;
AbuDagga, H .
ACADEMIC RADIOLOGY, 1997, 4 (02) :138-149
[6]   MAXIMUM LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL DETECTION THEORY - A DIRECT SOLUTION [J].
DORFMAN, DD ;
ALF, E .
PSYCHOMETRIKA, 1968, 33 (01) :117-&
[7]  
Egan JP., 1975, SIGNAL DETECTION THE
[8]  
GOOD WF, 1999, SPIE P, V3663, P8
[9]   SOME ASPECTS OF ROC CURVE-FITTING - NORMAL AND LOGISTIC MODELS [J].
GREY, DR ;
MORGAN, BJT .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1972, 9 (01) :128-&
[10]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36