Two-phase flow metering of heavy oil using a Coriolis mass flow meter: A case study

被引:53
作者
Henry, Manus
Tombs, Michael
Duta, Mihaela
Zhou, Feibiao
Mercado, Ronaldo
Kenyery, Frank
Shen, Joseph
Morles, Martin
Garcia, Carlos
Langansan, Robbie
机构
[1] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[2] Univ Simon Bolivar, Lab Convers Energia Mecan, Caracas 1080, Venezuela
[3] Chevron Energy Technol Co, Houston, TX 77002 USA
[4] Invensys Proc Syst, Houston, TX 77041 USA
关键词
Coriolis mass flow metering; two-phase flow; high viscosity oil; heavy oil;
D O I
10.1016/j.flowmeasinst.2006.07.008
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The use of Coriolis mass flow metering for two-phase (gas/liquid) flow is an emerging theme of both academic research and industrial application. The key issues are maintaining flow-tube operation, and modelling and correcting for the errors induced in the mass flow and density measurements. Experimentally-derived data is used to illustrate that these errors vary most notably with gas void fraction (GVF) and liquid flow rate, but other factors such as flow-tube geometry and orientation, and fluid properties such as viscosity are also influential. While undoubtedly a universal two-phase flow correction model is the ultimate research goal, there is currently no obvious candidate to explain the range of behaviours observed. This paper describes and demonstrates an empirical methodology that has proven effective in developing good correction models for a given choice of Coriolis flow-tube and flow mixture. A growing proportion of the world's oil reserves may be described as "heavy", implying high density and high viscosity. Of the various metering challenges heavy oil poses, one of the most significant is its ready entrainment of gas, and the difficulties entailed in separating gas from the oil. Accurate two-phase measurement of heavy oil is therefore an especially desirable technical goal. Trials were carried out at the National Engineering Laboratory (NEL), Scotland on a 75 mm flowmeter using a high viscosity oil. Flowrates from 1 kg/s to 10 kg/s were examined, with gas void fraction (GVF) up to 80%. The resulting models were tested online in a commercial Coriolis mass flow meter and demonstrated good performance for both steady and slugging two-phase flows, with the corrected measurements typically within 1%-5% of the nominal mass flow and density. Field trials in Venezuela have confirmed the performance of this two-phase solution. While research continues into the development of a generic two-phase correction, this case study demonstrates that the current state of the art can provide, for economically important fluids, tailored models with good two-phase flow performance. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:399 / 413
页数:15
相关论文
共 16 条
[1]  
*BSI, 2005, 389 BS7986
[2]  
CLARK C, 2006, FLOW MEASUREMENT INS
[3]  
Hemp J., 2003, IEE SEM ADV COR MASS
[4]  
Hemp J., 1989, INT C MASS FLOW MEAS, P21
[5]  
Henry M., 2005, ATP INT, V3, P24
[6]  
Henry M, 2005, SENSOR VALIDATION PR, P39
[7]  
Henry M. P., 2003, U.S. Patent, Patent No. [6 505 519, 6505519]
[8]  
Henry M. P., 2005, U.S. Patent, Patent No. [695 076 0 B2, 6950760]
[9]   Response of a Coriolis mass flow meter to step changes in flow rate [J].
Henry, MP ;
Clark, C ;
Duta, M ;
Cheesewright, R ;
Tombs, M .
FLOW MEASUREMENT AND INSTRUMENTATION, 2003, 14 (03) :109-118
[10]  
HENRY MP, 2001, Patent No. 6311136