Selective electrochemical sensing of calcium dobesilate based on an ordered mesoporous carbon-modified pyrolytic graphite electrode

被引:13
|
作者
Hu, Guangzhi [1 ,2 ]
Ma, Yonggen [1 ,2 ]
Guo, Yong [1 ]
Shao, Shijun [1 ]
机构
[1] Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R China
[2] Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China
关键词
Ordered mesoporous carbon; Pyrolytic graphite electrode; Calcium dobesilate; Electrochemical sensor; DIABETIC-RETINOPATHY; PERFORMANCE; NANOTUBES; COMPOSITE;
D O I
10.1016/j.jelechem.2009.06.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cyclic voltammetric investigation of calcium dobesilate (CD) in aqueous acid media was carried out by using an ordered mesoporous carbon-modified pyrolytic graphite electrode (OMC/PGE). A pair of well-defined redox peaks of CD was observed at the OMC/PGE, showing its good elelctrochemial response towards CD. The anodic current is linear with CD concentration in the range of 1.0 X 10(-7)- 1.3 X 10(-3) Mol L-1, with a detection limit of 4.0 x 10(-8) mol L-1. Meanwhile, the proposed electrode can avoid some interference coexisting with CD, such as uric acid, serotonin, and ascorbic acid. The proposed method can be potentially applied for selective electrochemical sensing of CD in physiological condition. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:264 / 267
页数:4
相关论文
共 50 条
  • [1] Selective electrochemical sensing of calcium dobesilate based on the nano-Pd/CNTs modified pyrolytic graphite electrode
    Hu, Guangzhi
    Chen, Long
    Guo, Yong
    Shao, Shijun
    Wang, Xiaolai
    TALANTA, 2009, 78 (03) : 1211 - 1214
  • [2] An amperometric sensor for uric acid based on ordered mesoporous carbon-modified pyrolytic graphite electrode
    Yonggen Ma
    Guangzhi Hu
    Shijun Shao
    Yong Guo
    Chemical Papers, 2009, 63 : 641 - 645
  • [3] An amperometric sensor for uric acid based on ordered mesoporous carbon-modified pyrolytic graphite electrode
    Ma, Yonggen
    Hu, Guangzhi
    Shao, Shijun
    Guo, Yong
    CHEMICAL PAPERS, 2009, 63 (06): : 641 - 645
  • [4] Ultrasensitive electrochemical sensing of the anticancer drug tirapazamine using an ordered mesoporous carbon modified pyrolytic graphite electrode
    Hu, Guangzhi
    Guo, Yong
    Shao, Shijun
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (11): : 3391 - 3394
  • [5] Electrochemical properties and simultaneous determination of dihydroxybenzene isomers at ordered mesoporous carbon-modified electrode
    Bai, Jing
    Guo, Liping
    Ndamanisha, Jean Chrysostome
    Qi, Bin
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (12) : 2497 - 2503
  • [6] Electrochemical properties and simultaneous determination of dihydroxybenzene isomers at ordered mesoporous carbon-modified electrode
    Jing Bai
    Liping Guo
    Jean Chrysostome Ndamanisha
    Bin Qi
    Journal of Applied Electrochemistry, 2009, 39 : 2497 - 2503
  • [7] Electrochemical behavior of L-cysteine and its detection at ordered mesoporous carbon-modified glassy carbon electrode
    Zhou, Ming
    Ding, Jie
    Guo, Li-ping
    Shang, Qing-kun
    ANALYTICAL CHEMISTRY, 2007, 79 (14) : 5328 - 5335
  • [8] A highly selective amperometric sensor for ascorbic acid based on mesopore-rich active carbon-modified pyrolytic graphite electrode
    Hu, Guangzhi
    Guo, Yong
    Xue, Quanmin
    Shao, Shijun
    ELECTROCHIMICA ACTA, 2010, 55 (08) : 2799 - 2804
  • [9] Ordered mesoporous carbon as electrode modification material for selective and sensitive electrochemical sensing of melamine
    Guo, Zhuo
    Xu, Xian-feng
    Li, Jian
    Liu, Yu-wei
    Zhang, Jia
    Yang, Chen
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 200 : 101 - 108
  • [10] Polyphenol oxidase/gold nanoparticles/mesoporous carbon-modified electrode as an electrochemical sensing platform for rutin in dark teas
    Zhong, Tongsheng
    Guo, Qianqiong
    Yin, Zhifang
    Zhu, Xiaoyan
    Liu, Rong
    Liu, Aijuan
    Huang, Shasheng
    RSC ADVANCES, 2019, 9 (04) : 2152 - 2155