Initial Experience, Safety, and Feasibility of Left Bundle Branch Area Pacing A Multicenter Prospective Study

被引:102
作者
Padala, Santosh K. [1 ]
Master, Vivak M. [1 ]
Terricabras, Maria [2 ]
Chiocchini, Andrea [2 ]
Garg, Aatish [1 ]
Kron, Jordana [1 ]
Shepard, Richard [1 ]
Kalahasty, Gautham [1 ]
Azizi, Zahara [2 ]
Tsang, Bernice [2 ]
Khaykin, Yaariv [2 ]
Pantano, Alfredo [2 ]
Koneru, Jayanthi N. [1 ]
Ellenbogen, Kenneth A. [1 ]
Verma, Atul [2 ]
机构
[1] Virginia Commonwealth Univ, Pauley Heart Ctr, Div Cardiol, Gateway Bldg,3rd Floor,3-216, Richmond, VA 23219 USA
[2] Univ Toronto, Southlake Reg Hlth Ctr, Div Cardiol, Toronto, ON, Canada
关键词
conduction system pacing; His bundle pacing; left bundle branch area pacing; physiological pacing; CARDIAC RESYNCHRONIZATION; SHORT-TERM;
D O I
10.1016/j.jacep.2020.07.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to evaluate the safety and feasibility of conduction system pacing by performing left bundle branch area pacing (LBBAP). BACKGROUND There are limited data from single centers showing that LBBAP may circumvent the technical and electrophysiological challenges encountered with His bundle pacing. METHODS Patients referred for pacemaker implantation at 2 centers between February 1, 2019, and March 31, 2020, were considered for LBBAP. LBBAP was performed by implanting a lumen-less, exposed helix lead approximately 2 cm distal to the His bundle and deep into the septum using a specialized delivery sheath. Implant success rates, complications, and electrophysiological parameters were assessed. RESULTS LBBAP was successful in 305 of 341 patients (89%). Mean age was 72 +/- 12 years; 45% were women; and 39% had QRS duration (QRSd) >130 ms, 22% right bundle branch block, 11% left bundle branch block, and 6% intraventricutar conduction defect. Pacing indications were sinus node dysfunction in 28.7%, atrioventricular block in 52.5%, cardiac resynchronization therapy in 8.8%, and refractory atrial fibrillation in 10% of patients. Procedural duration was 74.7 +/- 34 min and fluoroscopic time was 10.4 +/- 8.1 min. The mean baseline QRSd and paced QRSd in the overall cohort was 114 +/- 29.8 ms versus 112 +/- 11.7 ms (p < 0.001) and in patients with infra-Hisian disease was 144.5 +/- 19 ms versus 115 +/- 12 ms (p < 0.001), respectively. Mean left ventricular activation time was 71.7 +/- 11 ms at high output and 74.7 +/- 11 ms at low output. LBB potentials were noted in 41% patients. Pacing threshold and R waves were 0.74 0.3 Vat 0.4 ms and 10.7 4.9 mV at time of implantation and were stable at 1-, 3-, 6-, and 12-month follow-ups. The only major complications were 3 LBBAP lead dislodgements, 2 within 24 h and 1 at 2 weeks. CONCLUSIONS LBBA pacing is safe, feasible, and a reliable alternative to His bundle pacing for providing physiological pacing. Randomized controlled studies are needed to confirm the safety, feasibility, and clinical outcomes of LBBAP. (C) 2020 by the American College of Cardiology Foundation.
引用
收藏
页码:1773 / 1782
页数:10
相关论文
共 30 条
[1]  
Abdelrahman M, 2018, J AM COLL CARDIOL, V71, P2581, DOI [10.1016/j.jacc.2018.02.048, 10.1016/S0735-1097(18)33122-X]
[2]   The Efficacy of His Bundle Pacing: Lessons Learned From Implementation for the First Time at an Experienced Electrophysiology Center [J].
Bhatt, Advay G. ;
Musat, Dan L. ;
Milstein, Nicolle ;
Pimienta, Jacqueline ;
Flynn, Laura ;
Sichrovsky, Tina ;
Preminger, Mark W. ;
Mittal, Suneet .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (11) :1397-1406
[3]   Evaluation of cardiac synchrony in left bundle branch pacing: Insights from echocardiographic research [J].
Cai, Binni ;
Huang, Xinyi ;
Li, Linlin ;
Guo, Jincun ;
Chen, Simei ;
Meng, Fanqi ;
Wang, Huimin ;
Lin, Biqin ;
Su, Maolong .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (02) :560-569
[4]   Acute Lead Dislodgements and In-Hospital Mortality in Patients Enrolled in the National Cardiovascular Data Registry Implantable Cardioverter Defibrillator Registry [J].
Cheng, Alan ;
Wang, Yongfei ;
Curtis, Jeptha P. ;
Varosy, Paul D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (20) :1651-1656
[5]   Inferior lead discordance in ventricular arrhythmias: A specific marker for certain arrhythmia locations [J].
Enriquez, Andres ;
Pathak, Rajeev K. ;
Santangeli, Pasquale ;
Liang, Jackson J. ;
Al Rawahi, Mohammed ;
Hayashi, Tatsuya ;
Muser, Daniele ;
Frankel, David S. ;
Supple, Gregory ;
Schaller, Robert ;
Lin, David ;
Nazarian, Saman ;
Zado, Erica ;
Marchlinski, Francis E. ;
Garcia, Fermin C. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (10) :1179-1186
[6]   Short-term and intermediate-term performance and safety of left bundle branch pacing [J].
Guo, Jincun ;
Li, Linlin ;
Meng, Fanqi ;
Su, Maolong ;
Huang, Xinyi ;
Chen, Simei ;
Li, Qiang ;
Chang, Dong ;
Cai, Binni .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) :1472-1481
[7]   Feasibility and cardiac synchrony of permanent left bundle branch pacing through the interventricular septum [J].
Hou, Xiaofeng ;
Qian, Zhiyong ;
Wang, Yao ;
Qiu, Yuanhao ;
Chen, Xing ;
Jiang, Hai ;
Jiang, Zeyu ;
Wu, Hongping ;
Zhao, Zhongqiang ;
Zhou, Weihua ;
Zou, Jiangang .
EUROPACE, 2019, 21 (11) :1694-1702
[8]   A beginner's guide to permanent left bundle branch pacing [J].
Huang, Weijian ;
Chen, Xueying ;
Su, Lan ;
Wu, Shengjie ;
Xia, Xue ;
Vijayaraman, Pugazhendhi .
HEART RHYTHM, 2019, 16 (12) :1791-1796
[9]   A Novel Pacing Strategy With Low and Stable Output: Pacing the Left Bundle Branch Immediately Beyond the Conduction Block [J].
Huang, Weijian ;
Su, Lan ;
Wu, Shengjie ;
Xu, Lei ;
Xiao, Fangyi ;
Zhou, Xiaohong ;
Ellenbogen, Kenneth A. .
CANADIAN JOURNAL OF CARDIOLOGY, 2017, 33 (12) :1736.e1-1736.e3
[10]   Programmed deep septal stimulation: A novel maneuver for the diagnosis of left bundle branch capture during permanent pacing [J].
Jastrzebski, Marek ;
Moskal, Pawel ;
Bednarek, Agnieszka ;
Kielbasa, Grzegorz ;
Kusiak, Aleksander ;
Sondej, Tomasz ;
Bednarski, Adam ;
Vijayaraman, Pugazhendhi ;
Czarnecka, Danuta .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (02) :485-493