Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography

被引:61
作者
Marx, Axel
von Knoch, Marius
Pfoertner, Joerg
Wiese, Matthias
Saxler, Guido
机构
[1] Univ Duisburg Essen, Dept Orthopaed Surg, D-45122 Essen, Germany
[2] Univ Bochum, Dept Orthopaed Surg, D-44791 Bochum, Germany
关键词
hip arthroplasty; anteversion; planar radiography; CT-based navigation system;
D O I
10.1007/s00402-006-0163-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Anteroposterior pelvic radiographs are routinely used to monitor cup orientation in total hip arthroplasty (THA). Analysis of planar radiographs leads to a certain degree of measurement error for the cup anteversion (AV). With the current study, we wanted to clarify whether planar radiography can be used for accurate evaluation of the THA position. Materials and methods The postoperative orientation of pelvic implants in 42 patients was analyzed according to five documented mathematical algorithms using planar radiographs. Postoperative computed tomography (CT) pelvis scans were available for all patients. A CT-based navigation system was used to determine AV. Results The comparison showed that all five formulas presented substantial variations for the AV angle. Of these, Widmer's algorithm presented the smallest difference compared to the CT. Misinterpretation of postoperative planar radiographs is a common problem in THA. Conclusion Planar radiographs are too imprecise for exact evaluation of the correct cup AV after THA. CT-based analysis may be necessary if exact values are required.
引用
收藏
页码:487 / 492
页数:6
相关论文
共 30 条
  • [1] ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT
    ACKLAND, MK
    BOURNE, WB
    UHTHOFF, HK
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03): : 409 - 413
  • [2] Method for the evaluation of factors influencing the dislocation stability of total hip endoprotheses
    Bader, R
    Scholz, R
    Steinhauser, E
    Busch, R
    Mittlemeier, W
    [J]. BIOMEDIZINISCHE TECHNIK, 2004, 49 (05): : 137 - 144
  • [3] Bernsmann K, 2001, Z ORTHOP GRENZGEB, V139, P512
  • [4] 2,012 TOTAL HIP ARTHROPLASTIES - STUDY OF POSTOPERATIVE COURSE AND EARLY COMPLICATIONS
    COVENTRY, MB
    BECKENBAUGH, RD
    NOLAN, DR
    ILSTRUP, DM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (02) : 273 - 284
  • [5] Der G., 2002, HDB STAT ANAL USING, V2nd
  • [6] FACKLER CD, 1980, CLIN ORTHOP RELAT R, V151, P169
  • [7] RADIOGRAPHIC LOCALIZATION OF THE ACETABULAR COMPONENT OF A HIP PROSTHESIS
    GHELMAN, B
    [J]. RADIOLOGY, 1979, 130 (02) : 540 - 542
  • [8] GRUTZNER PA, 2004, INJURY S1, V35, pS5
  • [9] Accuracy of intraoperative assessment of acetabular prosthesis placement
    Hassan, DM
    Johnston, GHF
    Dust, WNC
    Watson, G
    Dolovich, AT
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (01) : 80 - 84
  • [10] HERRLIN K, 1988, ACTA RADIOL, V29, P357