Robustness study of the different immittance spectra and frequency ranges in bioimpedance spectroscopy analysis for assessment of total body composition

被引:22
作者
Buendia, R. [1 ,2 ,3 ]
Seoane, F. [1 ,3 ]
Bosaeus, I. [4 ]
Gil-Pita, R. [2 ]
Johannsson, G. [5 ]
Ellegard, L. [5 ]
Lindecrantz, K. [1 ,6 ]
机构
[1] KTH Royal Inst Technol, Dept Med Sensors Signals & Syst, SE-14152 Stockholm, Sweden
[2] Univ Alcala de Henares, Dept Signal Theory & Commun, E-28871 Madrid, Spain
[3] Univ Boras, Sch Engn, SE-50190 Boras, Sweden
[4] Univ Gothenburg, Sahlgrenska Acad, Sahlgrenska Univ Hosp, Dept Clin Nutr, SE-40530 Gothenburg, Sweden
[5] Sahlgrens Univ Hosp, Dept Internal Med, Endocrine Sect, Gothenburg, Sweden
[6] Karolinska Inst, Dept Clin Sci Intervent & Technol, SE-14186 Stockholm, Sweden
关键词
bioimpedance; bioconductance; measurement artefacts; body composition; IMPEDANCE SPECTROSCOPY; POTASSIUM; ADULTS;
D O I
10.1088/0967-3334/35/7/1373
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The estimation of body fluids is a useful and common practice for assessment of disease status and therapy outcomes. Electrical bioimpedance spectroscopy (EBIS) methods are noninvasive, inexpensive and efficient alternatives for determination of body fluids. One of the main source of errors in EBIS measurements in the estimation of body fluids is capacitive coupling. In this paper an analysis of capacitive coupling in EBIS measurements was performed and the robustness of the different immittance spectra against it tested. On simulations the conductance (G) spectrum presented the smallest overall error, among all immittance spectra, in the estimation of the impedance parameters used to estimate body fluids. Afterwards the frequency range of 10-500 kHz showed to be the most robust band of the G spectrum. The accuracy of body fluid estimations from the resulting parameters that utilized G spectrum and parameters provided by the measuring device were tested on EBIS clinical measurements from growth hormone replacement therapy patients against estimations performed with dilution methods. Regarding extracellular fluid, the correlation between each EBIS method and dilution was 0.93 with limits of agreement of 1.06 +/- 2.95 l for the device, 1.10 +/- 2.94 l for G [10-500 kHz] and 1.04 +/- 2.94 l for G [5-1000 kHz]. Regarding intracellular fluid, the correlation between dilution and the device was 0.91, same as for G [10-500 kHz] and 0.92 for G [5- 1000 kHz]. Limits of agreement were 0.12 +/- 4.46 l for the device, 0.09 +/- 4.45 for G [10- 500 kHz] and 0.04 +/- 4.58 for G [5-1000 kHz]. Such close results between the EBIS methods validate the proposed approach of using G spectrum for initial Cole characterization and posterior clinical estimation of body fluids status.
引用
收藏
页码:1373 / 1395
页数:23
相关论文
共 29 条
  • [1] Cole Equation and Parameter Estimation from Electrical Bioimpedance Spectroscopy Measurements - A Comparative Study
    Ayllon, David
    Seoane, Fernando
    Gil-Pita, Roberto
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3779 - 3782
  • [2] Batra S P, 2012, ACEEE INT J ELECT PO, V3, P12
  • [3] Measurement errors in multifrequency bioelectrical impedance analyzers with and without impedance electrode mismatch
    Bogonez-Franco, P.
    Nescolarde, L.
    Bragos, R.
    Rosell-Ferrer, J.
    Yandiola, I.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2009, 30 (07) : 573 - 587
  • [4] Sources of error in bioimpedance spectroscopy
    Bolton, MP
    Ward, LC
    Khan, A
    Campbell, I
    Nightingale, P
    Dewit, O
    Elia, M
    [J]. PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) : 235 - 245
  • [5] BODY-COMPOSITION - PREDICTION OF NORMAL BODY POTASSIUM, BODY-WATER AND BODY-FAT IN ADULTS ON THE BASIS OF BODY HEIGHT, BODY-WEIGHT AND AGE
    BRUCE, A
    ANDERSSON, M
    ARVIDSSON, B
    ISAKSSON, B
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1980, 40 (05) : 461 - 473
  • [6] Experimental validation of a method for removing the capacitive leakage artifact from electrical bioimpedance spectroscopy measurements
    Buendia, R.
    Seoane, F.
    Gil-Pita, R.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (11)
  • [7] Buendia R, 2010, P 32 ANN C IEEE ENG, V1, P6563
  • [8] Buéndía R, 2011, IEEE ENG MED BIO, P1843, DOI 10.1109/IEMBS.2011.6090524
  • [9] Buendia Ruben., 2019, Journal of Electrical Bioimpedance, V2, P72, DOI DOI 10.5617/JEB.197
  • [10] Cole K. S., 1940, Cold Spring Harbor Symposia on Quantitative Biology, V8, P110