Non-contrast-Enhanced Flow-Independent Peripheral MR Angiography with Balanced SSFP

被引:36
作者
Cukur, Tolga [1 ]
Lee, Jin H. [1 ]
Bangerter, Neal K. [2 ]
Hargreaves, Brian A. [2 ]
Nishimura, Dwight G. [1 ]
机构
[1] Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
peripheral angiography; non-contrast-enhanced; magnetic resonance angiography; SSFP; fat suppression; STATE FREE PRECESSION; STEADY-STATE; WATER SEPARATION; FAT; BLOOD;
D O I
10.1002/mrm.21921
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Flow-independent angiography is a non-contrast-enhanced technique that can generate vessel contrast even with reduced blood flow in the lower extremities. A method is presented for producing these angiograms with magnetization-prepared balanced steady-state free precession (bSSFP). Because bSSFP yields bright fat signal, robust fat suppression is essential for detailed depiction of the vasculature. Therefore, several strategies have been investigated to improve the reliability of fat suppression within short scan times. Phase-sensitive SSFP can efficiently suppress fat; however, partial volume effects due to fat and water occupying the same voxel can lead to the loss of blood signal. In contrast, alternating repetition time (ATR) SSFP minimizes this loss; however, the level of suppression is compromised by field inhomogeneity. Finally, a new double-acquisition ATR-SSFP technique reduces this sensitivity to off-resonance. In vivo results indicate that the two ATR-based techniques provide more reliable contrast when partial volume effects are significant. Magn Reson Med 61:1533-1539, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1533 / 1539
页数:7
相关论文
共 37 条
  • [11] Dual-acquisition phase-sensitive fat-water separation using balanced steady-state free precession
    Hargreaves, BA
    Bangerter, NK
    Shimakawa, A
    Vasanawala, SS
    Brittain, JH
    Nishimura, DG
    [J]. MAGNETIC RESONANCE IMAGING, 2006, 24 (02) : 113 - 122
  • [12] Fat-suppressed steady-state free precession imaging using phase detection
    Hargreaves, BA
    Vasanawala, SS
    Nayak, KS
    Hu, BS
    Nishimura, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) : 210 - 213
  • [13] Hargreaves BA., 2008, Proceedings of the 16th Annual Meeting of ISMRM, P1357
  • [14] Joint estimation of water/fat images and field inhomogeneity map
    Hernando, D.
    Haldar, J. P.
    Sutton, B. P.
    Ma, J.
    Kellman, P.
    Liang, Z. -P.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) : 571 - 580
  • [15] Fat and water separation in balanced steady-state free precession using the Dixon method
    Huang, TY
    Chung, HW
    Wang, FN
    Ko, CW
    Chen, CY
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 243 - 247
  • [16] ALTERED PHASE-ENCODING ORDER FOR REDUCED SENSITIVITY TO MOTION IN 3-DIMENSIONAL MR IMAGING
    KORIN, HW
    RIEDERER, SJ
    BAMPTON, AEH
    EHMAN, RL
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (06): : 687 - 693
  • [17] Lee T., 2003, Proceedings of the 11 th Annual Meeting of Proc Intl Soc Mag Reson Med, P131
  • [18] Alternating repetition time balanced steady state free precession
    Leupold, J
    Hennig, J
    Scheffler, K
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) : 557 - 565
  • [19] INTRACRANIAL VASCULAR-LESIONS - OPTIMIZATION AND CLINICAL-EVALUATION OF 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY
    MARCHAL, G
    BOSMANS, H
    VANFRAEYENHOVEN, L
    WILMS, G
    VANHECKE, P
    PLETS, C
    BAERT, AL
    [J]. RADIOLOGY, 1990, 175 (02) : 443 - 448
  • [20] Nephrogenic systemic fibrosis: Suspected causative role of gadodiamide used for contrast-enhanced magnetic resonance imaging
    Marckmann, Peter
    Skov, Lone
    Rossen, Kristian
    Dupont, Anders
    Damholt, Mette Brimnes
    Heaf, James Goya
    Thomsen, Henrik S.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2006, 17 (09): : 2359 - 2362