Modeling the effect of computer-aided detection on the sensitivity of screening mammography

被引:0
|
作者
Nishikawa, Robert M.
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Committee Med Phys, Chicago, IL 60637 USA
来源
关键词
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We have developed a Monte Carlo model to examine the cancer detection rate in screening mammography. We simulated the situation where screening was implemented for 9 years and then CADe was implemented for an additional 9 years. We investigated the effectiveness of two different methods for measuring changes in cancer detection rate. The first method was a sequential method in which the radiologist first reads without CADe and then immediately reads with CADe. The second method is temporal comparison where the cancer detection rates for two periods of time are compared: one without the use of CADe and one when CADe is in use. The model predictions have important implications for clinical studies of CADe. The temporal method is unlikely to measure a real affect, because the effect is small. A sequential method can measure an increase in the number of cancers detected because of CADe, but it cannot measure an overall increase in the cancer detection rate of the screening program.
引用
收藏
页码:46 / 53
页数:8
相关论文
共 50 条
  • [31] How Widely Is Computer-Aided Detection Used in Screening and Diagnostic Mammography?
    Rao, Vijay M.
    Levin, David C.
    Parker, Laurence
    Cavanaugh, Barbara
    Frangos, Andrea J.
    Sunshine, Jonathan H.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2010, 7 (10) : 802 - 805
  • [32] False Positive Marks on Unsuspicious Screening Mammography with Computer-Aided Detection
    Mary C. Mahoney
    Karthikeyan Meganathan
    Journal of Digital Imaging, 2011, 24 : 772 - 777
  • [33] Impact of computer-aided detection (CAD) in a regional screening mammography program
    Cupples, TE
    RADIOLOGY, 2001, 221 : 520 - 520
  • [34] Computer-aided detection in oncologic imaging: Screening mammography as a case study
    Castellino, RA
    CANCER JOURNAL, 2002, 8 (02): : 93 - 99
  • [35] Diagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
    Lehman, Constance D.
    Wellman, Robert D.
    Buist, Diana S. M.
    Kerlikowske, Karla
    Tosteson, Anna N. A.
    Miglioretti, Diana L.
    JAMA INTERNAL MEDICINE, 2015, 175 (11) : 1828 - 1837
  • [36] A computer-aided design mammography screening system for detection and classification of microcalcifications
    Lee, SK
    Lo, CS
    Wang, CM
    Chung, PC
    Chang, CI
    Yang, CW
    Hsu, PC
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2000, 60 (01) : 29 - 57
  • [37] Computer-aided detection (CAD) in screening mammography: Sensitivity of commercial CAD systems for detecting architectural distortion
    Baker, JA
    Rosen, EL
    Lo, JY
    Gimenez, EI
    Welsh, R
    Soo, MS
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (04) : 1083 - 1088
  • [38] Legal Ramifications of Computer-Aided Detection in Mammography
    Mezrich, Jonathan L.
    Siegel, Eliot L.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2015, 12 (06) : 572 - 574
  • [39] Computer-Aided Detection Systems for Digital Mammography
    Perez-Diaz, Marlen
    Orozco-Morales, Ruben
    Suarez-Aday, Eduardo
    Pirchio, Rosana
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 265 - 271
  • [40] Fast detection of masses in computer-aided mammography
    Christoyianni, I
    Dermatas, E
    Kokkinakis, G
    IEEE SIGNAL PROCESSING MAGAZINE, 2000, 17 (01) : 54 - 64