Computerized detection of vertebral compression fractures on lateral chest radiographs: Preliminary results with a tool for early detection of osteoporosis

被引:22
作者
Kasai, Satoshi [1 ]
Li, Feng [1 ]
Shiraishi, Junji [1 ]
Li, Qiang [1 ]
Doi, Kunio [1 ]
机构
[1] Univ Chicago, Dept Radiol, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
关键词
osteoporosis; vertebral compression fracture; lateral chest radiograph; computer-aided diagnosis;
D O I
10.1118/1.2364053
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Vertebral fracture (or vertebral deformity) is a very common outcome of osteoporosis, which is one of the major public health concerns in the world. Early detection of vertebral fractures is important because timely pharmacologic intervention can reduce the risk of subsequent additional fractures. Chest radiographs are used routinely for detection of lung and heart diseases, and vertebral fractures can be visible on lateral chest radiographs. However, investigators noted that about 50% of vertebral fractures visible on lateral chest radiographs were underdiagnosed or under-reported, even when the fractures were severe. Therefore, our goal was to develop a computerized method for detection of vertebral fractures on lateral chest radiographs in order to assist radiologists' image interpretation and thus allow the early diagnosis of osteoporosis. The cases used in this study were 20 patients with severe vertebral fractures and 118 patients without fractures, as confirmed by the consensus of two radiologists. Radiologists identified the locations of fractured vertebrae, and they provided morphometric data on the vertebral shape for evaluation of the accuracy of detecting vertebral end plates by computer. In our computerized method, a curved search area, which included a number of vertebral end plates, was first extracted automatically, and was straightened so that vertebral end plates became oriented horizontally. Edge candidates were enhanced by use of a horizontal line-enhancement filter in the straightened image, and a multiple thresholding technique, followed by feature analysis, was used for identification of the vertebral end plates. The height of each vertebra was determined from locations of identified vertebral end plates, and fractured vertebrae were detected by comparison of the measured vertebral height with the expected height. The sensitivity of our computerized method for detection of fracture cases was 95% (19/20), with 1.03 (139/135) false-positive fractures per image. The accuracy of identifying vertebral end plates, marked by radiologists in a morphometric study, was 76.6% (400/522) and 70.9% (420/592) for cases used for training and those for testing, respectively. We prepared 32 additional fracture cases for a validation test, and we examined the detection accuracy of our computerized method. The sensitivity for these cases was 75% (24/32) at 1.03 (33/32) false-positive fractures per image. Our preliminary results show that the automated computerized scheme for detecting vertebral fractures on lateral chest radiographs has the potential to assist radiologists in detecting vertebral fractures. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4664 / 4674
页数:11
相关论文
共 43 条
  • [1] Automated computerized scheme for detection of unruptured intracranial aneurysms in three-dimensional magnetic resonance angiography
    Arimura, H
    Li, Q
    Korogi, Y
    Hirai, T
    Abe, H
    Yamashita, Y
    Katsuragawa, S
    Ikeda, R
    Doi, K
    [J]. ACADEMIC RADIOLOGY, 2004, 11 (10) : 1093 - 1104
  • [2] Effect of an artificial neural network on radiologists' performance in the differential diagnosis of interstitial lung disease using chest radiographs
    Ashizawa, K
    MacMahon, H
    Ishida, T
    Nakamura, K
    Vyborny, CJ
    Katsuragawa, S
    Doi, K
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (05) : 1311 - 1315
  • [3] Artificial neural networks in chest radiography: Application to the differential diagnosis of interstitial lung disease
    Ashizawa, K
    Ishida, T
    MacMahon, H
    Vyborny, CJ
    Katsuragawa, S
    Doi, K
    [J]. ACADEMIC RADIOLOGY, 1999, 6 (01) : 2 - 9
  • [4] Computer-aided detection with screening mammography in a university hospital setting
    Birdwell, RL
    Bandodkar, P
    Ikeda, DM
    [J]. RADIOLOGY, 2005, 236 (02) : 451 - 457
  • [5] Prevalent vertebral deformities predict hip fractures and new vertebral deformities but not wrist fractures
    Black, DM
    Arden, NK
    Palermo, L
    Pearson, J
    Cummings, SR
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (05) : 821 - 828
  • [6] Randomised trial of effect of alendronate on risk of fracture in women with existing vertebral fractures
    Black, DM
    Cummings, SR
    Karpf, DB
    Cauley, JA
    Thompson, DE
    Nevitt, MC
    Bauer, DC
    Genant, HK
    Haskell, WL
    Marcus, R
    Ott, SM
    Torner, JC
    Quandt, SA
    Reiss, TF
    Ensrud, KE
    [J]. LANCET, 1996, 348 (9041) : 1535 - 1541
  • [7] Computer-aided detection in diagnostic mammography: Detection of clinically unsuspected cancers
    Butler, SA
    Gabbay, RJ
    Kass, DA
    Siedler, DE
    O'Shaughnessy, KF
    Castellino, RA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) : 1511 - 1515
  • [8] IMPROVEMENT IN RADIOLOGISTS DETECTION OF CLUSTERED MICROCALCIFICATIONS ON MAMMOGRAMS - THE POTENTIAL OF COMPUTER-AIDED DIAGNOSIS
    CHAN, HP
    DOI, K
    VYBORNY, CJ
    SCHMIDT, RA
    METZ, CE
    LAM, KL
    OGURA, T
    WU, YZ
    MACMAHON, H
    [J]. INVESTIGATIVE RADIOLOGY, 1990, 25 (10) : 1102 - 1110
  • [9] A randomized trial of nasal spray salmon calcitonin in postmenopausal women with established osteoporosis: the prevent recurrence of osteoporotic fractures study
    Chesnut, CH
    Silverman, S
    Andriano, K
    Genant, H
    Gimona, A
    Harris, S
    Kiel, D
    LeBoff, M
    Maricic, M
    Miller, P
    Moniz, C
    Peacock, M
    Richardson, P
    Watts, N
    Baylink, D
    [J]. AMERICAN JOURNAL OF MEDICINE, 2000, 109 (04) : 267 - 276
  • [10] Impact of computer-aided detection in a regional screening mammography program
    Cupples, TE
    Cunningham, JE
    Reynolds, JC