Solid phase microextraction (SPME)-transmission mode (TM) pushes down detection limits in direct analysis in real time (DART)

被引:92
作者
Gomez-Rios, German Augusto [1 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
DESORPTION ELECTROSPRAY-IONIZATION; TANDEM MASS-SPECTROMETRY; PAPER SPRAY; WHOLE-BLOOD; OPEN-AIR; DRUGS; SPOTS; SPME;
D O I
10.1039/c4cc05301j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new SPME device was developed and applied for quick solventless extraction/enrichment of small molecules from complex matrices. Subsequently, the device was coupled as a transmission mode substrate to DART resulting in limits of detection in the low pg mL(-1) level in less than 3 minutes with reproducibility below 5% RSD.
引用
收藏
页码:12937 / 12940
页数:4
相关论文
共 31 条
[1]   Low invasive in vivo tissue sampling for monitoring biomarkers and drugs during surgery [J].
Bojko, Barbara ;
Gorynski, Krzysztof ;
Gomez-Rios, German A. ;
Knaak, Jan M. ;
Machuca, Tiago ;
Cudjoe, Erasmus ;
Spetzler, Vinzent N. ;
Hsin, Michael ;
Cypel, Marcelo ;
Selzner, Markus ;
Liu, Mingyao ;
Keshjavee, Shaf ;
Pawliszyn, Janusz .
LABORATORY INVESTIGATION, 2014, 94 (05) :586-594
[2]   SPME - Quo vadis? [J].
Bojko, Barbara ;
Cudjoe, Erasmus ;
Gomez-Rios, German A. ;
Gorynski, Krzysztof ;
Jiang, Ruifen ;
Reyes-Garces, Nathaly ;
Risticevic, Sanja ;
Silva, Erica A. S. ;
Togunde, Oluranti ;
Vuckovic, Dajana ;
Pawliszyn, Janusz .
ANALYTICA CHIMICA ACTA, 2012, 750 :132-151
[3]   Introduction of solid-phase microextraction as a high-throughput sample preparation tool in laboratory analysis of prohibited substances [J].
Boyaci, Ezel ;
Gorynski, Krzysztof ;
Rodriguez-Lafuente, Angel ;
Bojko, Barbara ;
Pawliszyn, Janusz .
ANALYTICA CHIMICA ACTA, 2014, 809 :69-81
[4]   Recognition of beer brand based on multivariate analysis of volatile fingerprint [J].
Cajka, Tomas ;
Riddellova, Katerina ;
Tomaniova, Monika ;
Hajslova, Jana .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (25) :4195-4203
[5]   The Influence of Material and Mesh Characteristics on Transmission Mode Desorption Electrospray Ionization [J].
Chipuk, Joseph E. ;
Brodbelt, Jennifer S. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (04) :584-592
[6]   Transmission Mode Desorption Electrospray Ionization [J].
Chipuk, Joseph E. ;
Brodbelt, Jennifer S. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (11) :1612-1620
[7]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[8]   Ambient mass spectrometry [J].
Cooks, RG ;
Ouyang, Z ;
Takats, Z ;
Wiseman, JM .
SCIENCE, 2006, 311 (5767) :1566-1570
[9]  
Crawford E, 2011, BIOANALYSIS, V3, P1217, DOI [10.4155/BIO.11.99, 10.4155/bio.11.99]
[10]   Strategies for coupling solid-phase microextraction with mass spectrometry [J].
Deng, Jiewei ;
Yang, Yunyun ;
Wang, Xiaowei ;
Luan, Tiangang .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 55 :55-67