Adoption of Robotic vs Fluoroscopic Guidance in Total Hip Arthroplasty: Is Acetabular Positioning Improved in the Learning Curve?

被引:85
|
作者
Kamara, Eli [1 ]
Robinson, Jonathon [2 ]
Bas, Marcel A. [1 ]
Rodriguez, Jose A. [1 ]
Hepinstall, Matthew S. [1 ]
机构
[1] Lenox Hill Hosp, Dept Orthopaed Surg, 130 East 77th St,11th Floor, New York, NY 10075 USA
[2] Mt Sinai Hosp, Dept Orthopaed Surg, New York, NY 10029 USA
关键词
hip replacement; hip arthroplasty; robot; fluoroscopy; learning curve; acetabular component position; DIRECT ANTERIOR APPROACH; COMPONENT ORIENTATION; POSTERIOR APPROACH; POLYETHYLENE WEAR; REVISION HIP; FOLLOW-UP; SAFE ZONE; REPLACEMENT; RISK; OSTEOARTHRITIS;
D O I
10.1016/j.arth.2016.06.039
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Acetabulum positioning affects dislocation rates, component impingement, bearing surface wear rates, and need for revision surgery. Novel techniques purport to improve the accuracy and precision of acetabular component position, but may have a significant learning curve. Our aim was to assess whether adopting robotic or fluoroscopic techniques improve acetabulum positioning compared to manual total hip arthroplasty (THA) during the learning curve. Methods: Three types of THAs were compared in this retrospective cohort: (1) the first 100 fluoroscopically guided direct anterior THAs (fluoroscopic anterior [FA]) done by a surgeon learning the anterior approach, (2) the first 100 robotic-assisted posterior THAs done by a surgeon learning robotic-assisted surgery (robotic posterior [RP]), and (3) the last 100 manual posterior (MP) THAs done by each surgeon (200 THAs) before adoption of novel techniques. Component position was measured on plain radiographs. Radiographic measurements were taken by 2 blinded observers. The percentage of hips within the surgeons' "target zone" (inclination, 30 degrees-50 degrees ; anteversion, 10 degrees-30 degrees) was calculated, along with the percentage within the "safe zone" of Lewinnek (inclination, 30 degrees-50 degrees; anteversion, 5 degrees-25 degrees) and Callanan (inclination, 30 degrees-45 degrees; anteversion, 5 degrees-25 degrees). Relative risk (RR) and absolute risk reduction (ARR) were calculated. Variances (square of the standard deviations) were used to describe the variability of cup position. Results: Seventy-six percentage of MP THAs were within the surgeons' target zone compared with 84% of FA THAs and 97% of RP THAs. This difference was statistically significant, associated with a RR reduction of 87% (RR, 0.13 [0.04-0.40]; P < .01; ARR, 21%; number needed to treat, 5) for RP compared to MP THAs. Compared to FA THAs, RP THAs were associated with a RR reduction of 81% (RR, 0.19 [0.06-0.62]; P < .01; ARR, 13%; number needed to treat, 8). Variances were lower for acetabulum inclination and anteversion in RP THAs (14.0 and 19.5) as compared to the MP (37.5 and 56.3) and FA (24.5 and 54.6) groups. These differences were statistically significant (P < .01). Conclusion: Adoption of robotic techniques delivers significant and immediate improvement in the precision of acetabular component positioning during the learning curve. While fluoroscopy has been shown to be beneficial with experience, a learning curve exists before precision improves significantly. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:125 / 130
页数:6
相关论文
共 50 条
  • [31] Accuracy and safety of a new robotic arm for both femoral and acetabular side in total hip arthroplasty: a cadaveric study
    Lu, Xinzhe
    Zhang, Zian
    Wang, Wenzhe
    Xu, Hao
    Zhang, Haining
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [32] Acetabular Component Positioning in Total Hip Arthroplasty: An Evidence-Based Analysis
    Moskal, Joseph T.
    Capps, Susan G.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08) : 1432 - 1437
  • [33] Effect of Acetabular Component Positioning on Functional Outcomes in Primary Total Hip Arthroplasty
    Goyal, Prateek
    Lau, Adrian
    Naudie, Douglas D.
    Teeter, Matthew G.
    Lanting, Brent A.
    Howard, James L.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (03) : 843 - 848
  • [34] The Learning Curve Associated with Robotic Total Knee Arthroplasty
    Sodhi, Nipun
    Khlopas, Anton
    Piuzzi, Nicolas S.
    Sultan, Assem A.
    Marchand, Robert C.
    Malkani, Arthur L.
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2018, 31 (01) : 17 - 21
  • [35] Learning curve for active robotic total knee arthroplasty
    Mahure, Siddharth A.
    Teo, Greg Michael
    Kissin, Yair D.
    Stulberg, Bernard N.
    Kreuzer, Stefan
    Long, William J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (08) : 2666 - 2676
  • [36] Learning curve for active robotic total knee arthroplasty
    Siddharth A. Mahure
    Greg Michael Teo
    Yair D. Kissin
    Bernard N. Stulberg
    Stefan Kreuzer
    William J. Long
    Knee Surgery, Sports Traumatology, Arthroscopy, 2022, 30 : 2666 - 2676
  • [37] Utility of Intraoperative Fluoroscopic Positioning of Total Hip Arthroplasty Components Using a Posterior and Direct Anterior Approach
    Belyea, Christopher M.
    Lansford, Jefferson L.
    Yim, Duke G.
    MILITARY MEDICINE, 2022, 187 (1-2) : E11 - E16
  • [38] A Comparison of Component Positioning Between Fluoroscopy-Assisted and Robotic-Assisted Total Hip Arthroplasty
    Stewart, Nathaniel J.
    Stewart, James L.
    Brisbin, Abra
    JOURNAL OF ARTHROPLASTY, 2022, 37 (08) : 1602 - +
  • [39] TECHNIQUES FOR OPTIMIZING ACETABULAR COMPONENT POSITIONING IN TOTAL HIP ARTHROPLASTY Defining a Patient-Specific Functional Safe Zone
    Feng, James E.
    Anoushiravani, Afshin A.
    Eftekhary, Nima
    Wiznia, Daniel
    Schwarzkopf, Ran
    Vigdorchik, Jonathan M.
    JBJS REVIEWS, 2019, 7 (02)
  • [40] Contemporary analysis of the learning curve for robotic-assisted total hip arthroplasty emerging technologies
    Hecht, Christian J.
    Porto, Joshua R.
    Sanghvi, Parshva A.
    Homma, Yasuhiro
    Sculco, Peter K.
    Kamath, Atul F.
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)