Procedural results and outcomes after extensive stent coverage with drug-eluting stent implantation in single coronary lesions

被引:2
作者
Mishra, Sundeep [1 ]
Wolfram, Roswitha M. [1 ]
Torguson, Rebecca [1 ]
Xue, Zhenyi [1 ]
Gevorkian, Natalie [1 ]
Chu, William W. [1 ]
Satler, Lowell F. [1 ]
Pichard, Augusto D. [1 ]
Suddath, William O. [1 ]
Kent, Kenneth M. [1 ]
Waksman, Ron [1 ]
机构
[1] Washington Hosp Ctr, Div Cardiol, Washington, DC 20010 USA
关键词
D O I
10.1016/j.amjcard.2006.02.040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Longer stent length has remained associated with the incidence of major adverse cardiac events (MACEs) in the drug-eluting stent (DES) era; therefore, we aimed to determine clinical outcomes after extensive stent coverage with DES implantations in single coronary lesion. We evaluated the data from 99 consecutive patients treated with extensive DES coverage, defined as >= 50 mm (mean 63.3 +/- 13.2, range 50 to 115), and a concurrent series of 466 patients with <= 24-mm DES length (mean 18.4 +/- 3.8, range 8 to 24). The periprocedural, 1-, and 6-month outcomes were compared between the 2 groups. The baseline characteristics were mostly comparable between the 2 groups, and procedural and in-hospital outcomes were similar. Although the incidence of death and myocardial infarction at follow-up were comparable, the combined end points of target lesion revascularization plus MACEs at 6 months occurred more often with extensive stent coverage. Multivariate analysis revealed stent length to be the only independent predictor of target lesion revascularization plus MACEs. Patients treated with extensive DES coverage had similar procedural success, major in-hospital complications, and death and myocardial infarction at follow-up, but had more combined adverse events because of an overall higher target lesion revascularization rate. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:357 / 361
页数:5
相关论文
共 19 条
  • [1] Predictors of restenosis after coronary stent implantation
    Bauters, C
    Hubert, E
    Prat, A
    Bougrimi, K
    Van Belle, E
    McFadden, EP
    Amouyel, P
    Lablanche, JM
    Bertrand, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) : 1291 - 1298
  • [2] Intraprocedural stent thrombosis during implantation of sirolimus-eluting stents
    Chieffo, A
    Bonizzoni, E
    Orlic, D
    Stankovic, G
    Rogacka, R
    Airoldi, F
    Mikhail, GW
    Montorfano, M
    Michev, I
    Carlino, M
    Colombo, A
    [J]. CIRCULATION, 2004, 109 (22) : 2732 - 2736
  • [3] Impact of overlapping drug-eluting stents in patients undergoing percutaneous coronary intervention
    Chu, WW
    Kuchulakanti, PK
    Torguson, R
    Wang, B
    Clavijo, LC
    Suddath, WO
    Pichard, AD
    Satler, LF
    Kent, KM
    Waksman, R
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 67 (04) : 595 - 599
  • [4] Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions
    Colombo, A
    Drzewiecki, J
    Banning, A
    Grube, E
    Hauptmann, K
    Silber, S
    Dudek, D
    Fort, S
    Schiele, F
    Zmudka, K
    Guagliumi, G
    Russell, ME
    [J]. CIRCULATION, 2003, 108 (07) : 788 - 794
  • [5] Cutlip DE, 2001, CIRCULATION, V103, P1967
  • [6] Very long sirolimus-eluting stent implantation for de novo coronary lesions
    Degertekin, M
    Arampatzis, CA
    Lemos, PA
    Saia, F
    Hoye, A
    Daemen, J
    Tanabe, K
    Lee, CH
    Hofma, SJ
    Sianos, G
    McFadden, E
    van der Giessen, W
    Smits, PC
    De Feyter, PJ
    van Domburg, RT
    Serruys, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (07) : 826 - 829
  • [7] Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents
    Finn, AV
    Kolodgie, FD
    Harnek, J
    Guerrero, LJ
    Acampado, E
    Tefera, K
    Skorija, K
    Weber, DK
    Gold, HK
    Virmani, R
    [J]. CIRCULATION, 2005, 112 (02) : 270 - 278
  • [8] Six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions
    Grube, E
    Silber, S
    Hauptmann, KE
    Mueller, R
    Buellesfeld, L
    Gerckens, U
    Russell, ME
    [J]. CIRCULATION, 2003, 107 (01) : 38 - 42
  • [9] Angiographic and intravascular ultrasound predictors of in-stent restenosis
    Kasaoka, S
    Tobis, JM
    Akiyama, T
    Reimers, B
    Di Mario, C
    Wong, ND
    Colombo, A
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (06) : 1630 - 1635
  • [10] Predictive factors of restenosis after coronary stent placement
    Kastrati, A
    Schomig, A
    Elezi, S
    Schuhlen, H
    Dirschinger, J
    Hadamitzky, M
    Wehinger, A
    Hausleiter, J
    Walter, H
    Neumann, FJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (06) : 1428 - 1436