State Estimation of the Time-Varying and Spatially Localized Concentration of Signal Molecules from the Stochastic Adsorption Dynamics on the Carbon Nanotube-Based Sensors and Its Application to Tumor Cell Detection

被引:0
作者
Jang, Hong [1 ]
Lee, Jay H. [1 ]
Braatz, Richard D. [2 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Chem & Biomol Engn, Taejon 305701, South Korea
[2] MIT, Dept Chem Engn, Cambridge, MA 02139 USA
关键词
NITRIC-OXIDE; FLUORESCENT-PROBES; HYDROGEN-PEROXIDE; PARTICLE FILTERS; SMOOTH-MUSCLE; GROWTH; ROLES; PROLIFERATION; DEATH; ASSAY;
D O I
10.1371/journal.pone.0141930
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper addresses a problem of estimating time-varying, local concentrations of signal molecules with a carbon-nanotube (CNT)-based sensor array system, which sends signals triggered by monomolecular adsorption/desorption events of proximate molecules on the surfaces of the sensors. Such sensors work on nano-scale phenomena and show inherently stochastic non-Gaussian behavior, which is best represented by the chemical master equation (CME) describing the time evolution of the probabilities for all the possible number of adsorbed molecules. In the CME, the adsorption rate on each sensor is linearly proportional to the local concentration in the bulk phase. State estimators are proposed for these types of sensors that fully address their stochastic nature. For CNT-based sensors motivated by tumor cell detection, the particle filter, which is nonparametric and can handle non-Gaussian distributions, is compared to a Kalman filter that approximates the underlying distributions by Gaussians. In addition, the second-order generalized pseudo Bayesian estimation (GPB2) algorithm and the Markov chain Monte Carlo (MCMC) algorithm are incorporated into KF and PF respectively, for detecting latent drift in the concentration affected by different states of a cell.
引用
收藏
页数:21
相关论文
共 49 条
[41]   Vascular endothelial growth factor-induced endothelial cell migration and proliferation depend on a nitric oxide-mediated decrease in protein kinase Cδ activity [J].
Shizukuda, Y ;
Tang, SQ ;
Yokota, R ;
Ware, JA .
CIRCULATION RESEARCH, 1999, 85 (03) :247-256
[42]   H2O2 detection from intact mitochondria as a measure for one-electron reduction of dioxygen requires a non-invasive assay system [J].
Staniek, K ;
Nohl, H .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 1999, 1413 (02) :70-80
[43]  
Truskey G.A., 2009, TRANSPORT PHENOMENA, V2nd
[44]   Control of nano and microchemical systems [J].
Ulissi, Zachary W. ;
Strano, Michael S. ;
Braatz, Richard D. .
COMPUTERS & CHEMICAL ENGINEERING, 2013, 51 :149-156
[45]   Applicability of Birth-Death Markov Modeling for Single-Molecule Counting Using Single-Walled Carbon Nanotube Fluorescent Sensor Arrays [J].
Ulissi, Zachary W. ;
Zhang, Jingqing ;
Boghossian, Ardemis A. ;
Reuel, Nigel F. ;
Shimizu, Steven F. E. ;
Braatz, Richard D. ;
Strano, Michael S. .
JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2011, 2 (14) :1690-1694
[46]   Hydrogen peroxide sensing and signaling [J].
Veal, Elizabeth A. ;
Day, Alison M. ;
Morgan, Brian A. .
MOLECULAR CELL, 2007, 26 (01) :1-14
[47]   Fault Detection and Diagnosis Using Hidden Markov Disturbance Models [J].
Wong, Wee Chin ;
Lee, Jay H. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2010, 49 (17) :7901-7908
[48]   Realistic disturbance modeling using Hidden Markov Models: Applications in model-based process control [J].
Wong, Wee Chin ;
Lee, Jay H. .
JOURNAL OF PROCESS CONTROL, 2009, 19 (09) :1438-1450
[49]   Single Molecule Detection of Nitric Oxide Enabled by d(AT)15 DNA Adsorbed to Near Infrared Fluorescent Single-Walled Carbon Nanotubes [J].
Zhang, Jingqing ;
Boghossian, Ardemis A. ;
Barone, Paul W. ;
Rwei, Alina ;
Kim, Jong-Ho ;
Lin, Dahua ;
Heller, Daniel A. ;
Hilmer, Andrew J. ;
Nair, Nitish ;
Reuel, Nigel F. ;
Strano, Michael S. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (03) :567-581