摘要
Transition from low dose rate brachytherapy to high dose rate brachytherapy at our department necessitated the performance of dose verification test, which served as an end-to-end quality assurance procedure to verify and validate dose delivery in intracavitary brachytherapy of the cervix and the vaginal walls based on the Manchester system. An in-house water phantom was designed and constructed from Perspex sheets to represent the cervix region of a standard adult patient. The phantom was used to verify the whole dose delivery chain such as calibration of the cobalt-60 source in use, applicator, and source localization method, the output of treatment planning with dedicated treatment planning system, and actual dose delivery process. Since the above factors would influence the final dose delivered, doses were measured with calibrated gafchromic EBT3 films at various points within the in-house phantom for a number of clinical implants that were used to treat a patient based on departmental protocol. The measured doses were compared to those of the treatment planning system. The discrepancies between measured doses and their corresponding calculated doses obtained with the treatment planning system ranged from -29.67 to 40.34% (mean of +/- 13.27%). These compared similarly to other studies.
引用
收藏
页码:243 / 250
页数:8
相关论文
共 21 条
[1]   Evaluation of treatment planning system of brachytherapy according to dose to the rectum delivered [J].
Allahverdi, Mahmoud ;
Sarkhosh, Mina ;
Aghili, Mahdi ;
Jaberi, Ramin ;
Adelnia, Akbar ;
Geraily, Ghazale .
RADIATION PROTECTION DOSIMETRY, 2012, 150 (03) :312-315
[2]   Monte Carlo dosimetric study of the BEBIG Co-60HDR source [J].
Ballester, F ;
Granero, D ;
Pérez-Calatayud, J ;
Casal, E ;
Agramunt, S ;
Cases, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21) :N309-N316
[3]   Clinical application of MOSkin dosimeters to rectal wall in vivo dosimetry in gynecological HDR brachytherapy [J].
Carrara, M. ;
Romanyukha, A. ;
Tenconi, C. ;
Mazzeo, D. ;
Cerrotta, A. ;
Borroni, M. ;
Cutajar, D. ;
Petasecca, M. ;
Lerch, M. ;
Bucci, J. ;
Richetti, A. ;
Presilla, S. ;
Fallai, C. ;
Gambarini, G. ;
Pignoli, E. ;
Rosenfeld, A. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 41 :5-12
[4]  
Chao KS, 2002, PHILADELPHIA, P89
[5]   Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer [J].
De Leeuw, Astrid A. C. ;
Moerland, Marinus A. ;
Nomden, Christel ;
Tersteeg, Robert H. A. ;
Roesink, Judith M. ;
Jurgenliemk-Schulz, Ira M. .
RADIOTHERAPY AND ONCOLOGY, 2009, 93 (02) :341-346
[6]  
Garbaulet A, 2002, GEC ESTRO HDB BRACHY, V20, P473
[7]  
IAEA, 2010, IMPL INT COD PRACT D
[8]   Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors [J].
Karsch, L. ;
Beyreuther, E. ;
Burris-Mog, T. ;
Kraft, S. ;
Richter, C. ;
Zeil, K. ;
Pawelke, J. .
MEDICAL PHYSICS, 2012, 39 (05) :2447-2455
[9]   BRACHYTHERAPY DOSIMETRY SPECIAL FEATURE: REVIEW ARTICLE In vivo dosimetry: trends and prospects for brachytherapy [J].
Kertzscher, G. ;
Rosenfeld, A. ;
Beddar, S. ;
Tanderup, K. ;
Cygler, J. E. .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1041)
[10]   Identifying afterloading PDR and HDR brachytherapy errors using real-time fiber-coupled Al2O3:C dosimetry and a novel statistical error decision criterion [J].
Kertzscher, Gustavo ;
Andersen, Claus E. ;
Siebert, Frank-Andre ;
Nielsen, Soren Kynde ;
Lindegaard, Jacob C. ;
Tanderup, Kari .
RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) :456-462