Experimental determination of the critical loci for R-23+(n-propane or n-hexane) and R-116+n-propane binary mixtures

被引:8
作者
Williams-Wynn, Mark D. [1 ]
El Abbadi, Jamal [2 ]
Valtz, Alain [2 ]
Kovacs, Elodie [2 ]
Houriez, Celine [2 ]
Naidoo, Paramespri [1 ]
Coquelet, Christophe [2 ]
Ramjugernath, Deresh [1 ]
机构
[1] Univ KwaZulu Natal, Sch Engn, Thermodynam Res Unit, Howard Coll Campus,King George 5 Ave, ZA-4041 Durban, South Africa
[2] PSL Res Univ, MINES ParisTech, CTP, 35 Rue St Honore, F-77305 Fontainebleau, France
基金
新加坡国家研究基金会;
关键词
Critical loci; R-23; R-116; n-Propane; n-Hexane; VLE; LIQUID-EQUILIBRIUM DATA; VOLUME-TEMPERATURE RELATIONS; EQUATION-OF-STATE; PHASE-EQUILIBRIA; CARBON-DIOXIDE; PROPANE; SYSTEMS;
D O I
10.1016/j.jct.2016.12.021
中图分类号
O414.1 [热力学];
学科分类号
摘要
Isothermal VLE for the (R-23 + n-propane) system was measured using a static-analytic apparatus at temperatures between T = (293.18 and 353.15) K. The critical loci for the systems {R-23 + (n-propane or n-hexane)} and (R-116 + n-propane) were measured using a critical point determination apparatus. The method of Ungerer et al. was used to extrapolate the isothermal VLE data to the isothermal critical locus. These extrapolated critical loci were compared with experimental data. The Redlich-Kister type correlations were used to correlate the critical loci of the systems. A critical locus curve for the (R-23 + n-hexane) system which was calculated by the method of Heidemann and Khalil was compared with the experimental critical loci. The systems were classified according to the van Konynenburg and Scott classification system. (C) 2017 Elsevier Ltd.
引用
收藏
页码:84 / 96
页数:13
相关论文
共 27 条
  • [1] [Anonymous], 2013, NIST THERM ENG 103B
  • [2] [Anonymous], 2012, ASP PLUS V8 4
  • [3] NONPOLAR COSOLVENTS FOR SOLUBILITY ENHANCEMENT IN SUPERCRITICAL FLUID CARBON-DIOXIDE
    DOBBS, JM
    WONG, JM
    JOHNSTON, KP
    [J]. JOURNAL OF CHEMICAL AND ENGINEERING DATA, 1986, 31 (03) : 303 - 308
  • [4] Experimental measurement of vapor pressures and (vapor plus liquid) equilibrium for {1,1,1,2-tetrafluoroethane (R134a) + propane (R290)} by a recirculation apparatus with view windows
    Dong, Xueqiang
    Gong, Maoqiong
    Liu, Junsheng
    Wu, Jianfeng
    [J]. JOURNAL OF CHEMICAL THERMODYNAMICS, 2011, 43 (03) : 505 - 510
  • [5] Dortmund Data Bank (Ddb), 2012, DDBST SOFTW SEP TECH
  • [6] Isothermal Vapor-Liquid Equilibrium Data for the Perfluorobutane (R610) + Ethane System at Temperatures from (263 to 353) K
    El Ahmar, Elise
    Valtz, Alain
    Naidoo, Paramespri
    Coquelet, Cluistophe
    Ramjugernath, Deresh
    [J]. JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2011, 56 (05) : 1918 - 1924
  • [7] Experimental determination of the critical loci for {n-C6H14 or CO2 + alkan-1-ol} mixtures. Evaluation of their critical and subcritical behavior using PC-SAFT EoS
    Gil, Laura
    Blanco, Sofia T.
    Rivas, Clara
    Laga, Eduardo
    Fernandez, Javier
    Artal, Manuela
    Velasco, Inmaculada
    [J]. JOURNAL OF SUPERCRITICAL FLUIDS, 2012, 71 : 26 - 44
  • [8] Rapid on-line sampler-injector: a reliable tool for HT-HP sampling and on-line GC analysis
    Guilbot, P
    Valtz, A
    Legendre, H
    Richon, D
    [J]. ANALUSIS, 2000, 28 (05) : 426 - 431
  • [9] THE CALCULATION OF CRITICAL-POINTS
    HEIDEMANN, RA
    KHALIL, AM
    [J]. AICHE JOURNAL, 1980, 26 (05) : 769 - 779
  • [10] Hori K., 1982, P S THERM PROP ASME