Clinical Presentation and Outcomes of Cardiovascular Implantable Electronic Device Infections in Hemodialysis Patients

被引:35
作者
Hickson, LaTonya J. [1 ]
Gooden, Janelle Y. [1 ]
Le, Katherine Y. [1 ]
Baddour, Larry M. [1 ]
Friedman, Paul A. [1 ]
Hayes, David L. [1 ]
Wilson, Walter R. [1 ]
Steckelberg, James M. [1 ]
Sohail, M. Rizwan [1 ]
机构
[1] Mayo Clin, Rochester, MN 55905 USA
关键词
Bacteremia; defibrillator; hemodialysis; pacemaker; mortality; cardiovascular implantable electronic device (CIED); end-stage renal disease (ESRD); bloodstream infection; PERMANENT PACEMAKER; ENDOCARDITIS; DIALYSIS; MANAGEMENT; MORTALITY; SUDDEN; IMPACT; RATES; DEATH;
D O I
10.1053/j.ajkd.2013.11.018
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Infection is a serious complication of cardiovascular implantable electronic device (CIED) implantation. Kidney failure is as an independent risk factor for CIED infection and associated mortality. The presence of multiple comorbid conditions may contribute to varied clinical presentations and poor outcomes in hemodialysis (HD)-dependent patients with cardiac device infection. Study Design: Case series. Setting & Participants: CIED infections in HD patients (n = 17) and non-HD patients (n 5 398) at Mayo Clinic in Rochester, MN, between 1991 and 2008. Outcomes: Surgical management and death. Measurements: Clinical presentations, microbial organisms. Results: Of 415 patients admitted with CIED infection, 17 (4%) were receiving maintenance HD therapy. Among those on HD therapy, mean age was 72 +/- 15 (SD) years, 59% were women, and 53% had a central venous catheter for dialysis access. All 17 patients receiving HD therapy presented with CIED-associated bloodstream infection and 41% of these had infected vegetations on CIED leads or cardiac valves. A majority (82%) were managed with complete device removal and almost half (43%) received a replacement device when bloodstream infection cleared. Device infection was associated with significant short-term mortality in HD patients and 90-day survival was only 76% in this group of patients. Limitations: Smaller sample size, majority white cohort, observational study. Conclusions: CIED infection in patients receiving HD usually is associated with bloodstream infection and frequently is complicated with device-related endocarditis. Despite complete device removal in the majority of HD patients with infection, mortality remains high. (C) 2014 by the National Kidney Foundation, Inc.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 21 条
[1]   Transvenous Cardiac Implantable Electronic Devices and Hemodialysis Catheters: Recommendations to Curtail a Potentially Lethal Combination [J].
Asif, Arif ;
Salman, Loay ;
Lopera, Gustavo ;
Haqqie, Syed S. ;
Carrillo, Roger .
SEMINARS IN DIALYSIS, 2012, 25 (05) :582-586
[2]   Sudden and cardiac death rates in hemodialysis patients [J].
Bleyer, AJ ;
Russell, GB ;
Satko, SG .
KIDNEY INTERNATIONAL, 1999, 55 (04) :1553-1559
[3]   Renal insufficiency and the risk of infection from pacemaker or defibrillator surgery [J].
Bloom, H ;
Heeke, B ;
Leon, A ;
Mera, F ;
Delurgio, D ;
Beshai, J ;
Langberg, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (02) :142-145
[4]   Prevalence and Outcomes of Antimicrobial Treatment for Staphylococcus aureus Bacteremia in Outpatients with ESRD [J].
Chan, Kevin E. ;
Warren, H. Shaw ;
Thadhani, Ravi I. ;
Steele, David J. R. ;
Hymes, Jeffrey L. ;
Maddux, Franklin W. ;
Hakim, Raymond M. .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2012, 23 (09) :1551-1559
[5]   Trends in the Use and Outcomes of Implantable Cardioverter-Defibrillators in Patients Undergoing Dialysis in the United States [J].
Charytan, David M. ;
Patrick, Amanda R. ;
Liu, Jun ;
Setoguchi, Soko ;
Herzog, Charles A. ;
Brookhart, M. Alan ;
Winkelmayer, Wolfgang C. .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2011, 58 (03) :409-417
[6]   US Renal Data System 2012 Annual Data Report [J].
Collins, Allan J. ;
Foley, Robert N. ;
Herzog, Charles ;
Chavers, Blanche ;
Gilbertson, David ;
Herzog, Charles ;
Ishani, Areef ;
Johansen, Kirsten ;
Kasiske, Bertram ;
Kutner, Nancy ;
Liu, Jiannong ;
St. Peter, Wendy ;
Ding, Shu ;
Guo, Haifeng ;
Kats, Allyson ;
Lamb, Kenneth ;
Li, Shuling ;
Li, Suying ;
Roberts, Tricia ;
Skeans, Melissa ;
Snyder, Jon ;
Solid, Craig ;
Thompson, Bryn ;
Weinhandl, Eric ;
Xiong, Hui ;
Yusef, Akeem ;
Zaun, David ;
Arko, Cheryl ;
Chen, Shu-Cheng ;
Daniels, Frank ;
Ebben, James ;
Frazier, Eric ;
Hanzlik, Christopher ;
Johnson, Roger ;
Sheets, Daniel ;
Wang, Xinyue ;
Forrest, Beth ;
Constantini, Edward ;
Everson, Susan ;
Eggers, Paul ;
Agodoa, Lawrence .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2013, 61 (01) :E1-E459
[7]   Cardiovascular implantable electronic device infection: A stepwise approach to diagnosis and management [J].
Dababneh, Ala S. ;
Sohail, Muhammad R. .
CLEVELAND CLINIC JOURNAL OF MEDICINE, 2011, 78 (08) :529-537
[8]  
Fluck Richard, 2009, Nephron Clin Pract, V111 Suppl 1, pc247, DOI 10.1159/000210001
[9]   Timing of the Most Recent Device Procedure Influences the Clinical Outcome of Lead-Associated Endocarditis Results of the MEDIC (Multicenter Electrophysiologic Device Infection Cohort) [J].
Greenspon, Arnold J. ;
Prutkin, Jordan M. ;
Sohail, Muhammad R. ;
Vikram, Holenarasipur R. ;
Baddour, Larry M. ;
Danik, Stephan B. ;
Peacock, James ;
Falces, Carlos ;
Miro, Jose M. ;
Blank, Elisabeth ;
Naber, Christoph ;
Carrillo, Roger G. ;
Tseng, Chi-Hong ;
Uslan, Daniel Z. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (07) :681-687
[10]   Survival of dialysis patients after cardiac arrest and the impact of implantable cardioverter defibrillators [J].
Herzog, CA ;
Li, SL ;
Weinhandl, ED ;
Strief, JW ;
Collins, AJ ;
Gilbertson, DT .
KIDNEY INTERNATIONAL, 2005, 68 (02) :818-825